For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24-73.13 — OPERATIONAL STANDARDS

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-73.13

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/cce46f9f-d86d-4f56-8eb6-00ade0917b5c

Section 24-73.13 - OPERATIONAL STANDARDS

(1) In General. The operator is responsible for compliance with this section during all operations at the well. Any violation of any valid law or of any valid rule, regulation or requirement of any state or federal regulatory body having jurisdiction with reference to drilling, completing, equipping, operating, producing, maintaining, or abandoning oil or gas wells or related appurtenances, equipment or facilities, or with reference to firewall, fire protection, blow out protection or safety of persons or property shall be a violation of this section. (2) Well head setbacks. (a) No well shall be drilled or re-entered for deepening or conversion, the surface location of which is: (i) Within less than the height of the drilling rig plus twenty-five (25) feet from any street, alley or utility easement, unless the operator obtains a variance to be approved by the council. (ii) Within less than four hundred (400) feet from any residence or other permanent structure intended for human occupancy, unless the operator obtains a variance from council for which the operator provides notarized affidavits from all affected property owners within four hundred (400) feet of the proposed well stating consent to the proposed drilling or re-entry activity for deepening or conversion. (iii) Within less than four hundred (400) feet from any exterior boundary line or six hundred (600) feet from any building or land used by any public or parochial school, college, university, or hospital, or which is occupied by a church or a public building, unless the operator obtains a variance from council for which the operator provides notarized affidavits from all affected property owners within six hundred (600) feet from the proposed well stating consent to the proposed drilling or re-entry activity for deepening or conversion. (iv) Within less than four hundred (400) feet from the exterior boundary line of lands utilized for cemeteries or public parks, unless the operator obtains a variance from council. (b) No well shall be re-entered for reworking which does not involve deepening or conversion or for plugging and abandonment, the surface location of which is: (i) Within less than two hundred (200) feet from any residence or other permanent structure intended for human occupancy, unless the operator obtains a variance from council for which the operator provides notarized affidavits from all affected property owners within two hundred (200) feet of the proposed well stating consent to the proposed re-entry activity for reworking which does not involve deepening or conversion. (3) Development setbacks. Development setbacks shall be pursuant to the provisions in Section 24-77.2(12). (4) Mud requirements. Drilling mud shall be environmentally safe water-based fluid. No excess mud shall be allowed to accumulate on the site, and residues shall be removed following the completion of drilling operations. All post-drilling shavings shall be hauled out upon completion. (5) No well may be operated within the corporate limits where the hydrogen sulfide concentration exceeds the minimum standards authorized under Rule 36 of the statewide conservation rules. (6) Transport lines. Markers shall be installed to identify the location of collection and transport lines to prevent accidental rupture. (7) Pits. The use of earthen pits for reserve mud or waste material such as drilling mud, contaminated mud, drill stem test returns and the like shall not be permitted. However, earthen pits may be used for storage of fresh water and for drill cuttings only. A sump pit may be constructed and used to collect and temporarily hold runoffs from the rig. Upon completion of any well, any earthen pit and sump pits shall be emptied of contaminated materials, allowed to dry and filled with dirt and smooth leveled with the grade of the drilling block, and reseeded with native grass for erosion control. (8) Derricks and rigs. No operator shall use or operate any wooden derrick in connection with the drilling or reworking of any well, or permit any drilling rig or derrick to remain on the premises or drilling site for a period longer than sixty (60) days after completion or abandonment of any well. All engines shall be equipped with effective mufflers. (9) Drilling fluid. The bore hole of any well, while being drilled or reworked, shall at all times contain drilling fluid of sufficient density which a reasonably prudent operator in the area would use to keep the well under control. (10) Blowout preventer. Two (2) dually controlled, hydraulically activated ram-type blowout preventers with a manually operated lock with working pressure rating equal to the maximum anticipated wellhead pressure, but at least equal to the minimum internal yield pressure rating of the casing to which it is connected, shall be used for all drilling or completion operations involving the use of drill pipe or tubing after the surface casing has been set. For wells drilled to depths below protection casing an annular (Hydril) type blowout preventer shall be used in addition to the two (2) dually controlled blowout preventers specified. The mechanical operation of the blowout preventers shall be checked a minimum of every twenty-four (24) hours, recorded in a signed and dated log, and pressure tested prior to installation on each casing string at least once a week thereafter during the drilling and completing point. A choke manifold having the same working pressure rating as the preventers will be installed below the blowout preventer stack. In addition, the drilling rig, as part of its inventory, will have "inside blowout preventers" for each size and thread of tubing or drill pipe to be used in the drilling of such test well and any other type of safety equipment commonly used in the industry that may be requested by the superintendent. It is required that, upon obtaining a depth of three hundred (300) feet, a conductor lining or pipe be set and cemented to the bore hole throughout to the surface with attachment of adequate diverter or blowout preventers and testing thereof prior to drilling further. (11) Surface casing. All operators commencing drilling operations on a new well shall be required to set and cement a sufficient amount of surface casing to properly protect all fresh water sands in accordance with the requirements of the Texas Natural Resources Conservation Commission, the Texas Department of Health, and any other governmental agency having jurisdiction. The length of surface casing shall in no case be less than fifteen hundredths (0.15) of the length of the next string of pipe proposed to be set. The surface casing shall be new or used casing, inspected and pressure tested to have a minimum internal yield value, as defined by the API formula, of at least the product of one (1.0) pound per square inch times the total depth of which the surface casing is set and shall be cemented by the pump and plug method. A volume of cement shall be used which, according to accepted engineering procedures, is calculated to fill the annular space between the surface casing and well bore to the surface of the ground, the cement will be circulated with the pump until the returns of cement are observed at the surface of the ground, and the cement shall be allowed to stand for a period sufficient to develop one thousand (1,000) PSI compressive strength before the plug is drilled. If cement does not circulate to the surface, then in such event, a temperature survey shall be conducted to determine the depth reached by the cement, and at such time such remedial procedures shall be followed as directed by the superintendent. As to wells above four thousand (4,000) feet, the superintendent shall have the authority to grant exception to the surface casing requirements. (12) Setting and cementing casing. No well shall be drilled within the City limits without properly setting a conductor string of casing to a minimum depth of three hundred (300) feet below the surface of the ground. No wells shall be drilled without first cementing the casing string by the pump and plug method with a sufficient cement to completely fill all of the annular space behind such string to the surface of the ground. The same method shall be used for the cementing of the surface casing string to the sides of the hole. The production and/or protection string shall be cemented by the pump and plug method with sufficient cement to completely fill all of the annular space behind the production string to at least one hundred (100) feet above the highest oil and/or gas bearing horizons. (13) Production and protection casing. The producing or protection strings shall meet API specifications. Cementing shall be by the pump and plug method, and a volume of cement which is according to accepted engineering calculations, sufficient to fill the annular space between the casing and the well bore to a point at least one thousand (1,000) feet above the shoe, or the highest producing zone, whichever is the shallower depth. Cement shall be allowed to stand for a period sufficient to develop two thousand (2,000) PSI compressive strength before drilling the plug. (14) Drill stem tests. Open hole drill stem tests may be conducted only if the well effluent produced during the test is produced through an adequate oil and gas separator to storage vessels, the gas placed into a temporary line to flow into the air at a place approved by the superintendent, and the effluent remaining in the drill pipe at the time the tool is closed is flushed to the surface by circulating drilling fluid down the annulus and up the drill pipe. The superintendent shall shut down operations if, in the opinion of the superintendent, gas is being flared by the operator which is excessive or dangerous. (15) Formation pressures. No well shall be completed or operated in a zone which is reasonably anticipated to produce shut in pressures in excess of the working pressure rating of the standard API wellhead equipment on the well. (16) Wellheads. All wells shall be equipped with casingheads, tubingheads, and wellhead connections which conform to API standards. The casingheads used on such wells shall have working pressure ratings of not less than the highest pressure encountered in the area. All Christmas trees to be used by the operator in the City limits shall be tested to the related pressure after the same is installed, and a copy of such testings shall be furnished to the superintendent. The superintendent shall approve tubingheads and wellhead connections to be used on such wells which shall have working pressure ratings in excess of the well's shut in surface pressure. All such wells having a surface shut in pressure of three thousand (3,000) pounds per square inch or less shall be equipped with at least one (1) master valve and one (1) wing valve. All wells having surface shut in pressures in excess of three thousand (3,000) pounds per square inch shall be equipped with at least two (2) master valves and one (1) wing valve, and no such well shall have threaded connections between the surface safety valve and the Christmas tree. (17) Multiple completions. Multiple completions may be permitted by the superintendent when the casing, tubing and wellhead equipment is adequate, and the well is properly equipped with special packers for such purpose, together with all equipment customarily required for multiple completions. Except as provided in this section, multiple completion shall not be permitted. (18) Surface safety valves. A high-low surface safety valve shall be installed on all wells with a surface shut in pressure in excess of one thousand five hundred (1,500) pounds per square inch. In addition, a cutoff safety valve will be installed downstream from the wellhead equipment, or as directed by the superintendent. (19) Daily reports. Daily drilling reports shall be furnished by the operator to the superintendent. The superintendent or his agent will make periodic inspections, of all wells in the process of being drilled or completed to ascertain that all provisions of this article are being observed. Prior to the running of casing, cementing operations, installation of production equipment or perforation operations, the operator shall notify the office of the superintendent in sufficient time so that the superintendent may be present.

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.