§ 24-73.16 — WELLS TO BE ABANDONED
Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-73.16
Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/3fac7a4b-d3a1-48bb-8a30-f1f26bd520b0
Section 24-73.16 - WELLS TO BE ABANDONED
(1) All wells within the City limits which are not producing oil or gas on a regular basis will, be plugged and abandoned, except as follows: (a) Wells in use as water supply wells in compliance with rules and regulations of the Texas Natural Resources Conservation Commission and the Texas Department of Health. (b) Wells in use as salt water or waste disposal wells operating under a valid permit. (c) Wells used as injection or observation wells in secondary recovery, pressure maintenance or other improved recovery operations where such operations are conducted under a valid permit from the Railroad Commission. (d) Wells capable of producing oil or gas on a regular basis which are shut in. (e) Any well on which drilling, reworking, recompletion, or well servicing operations are in progress and continued with no cessation of more than ninety (90) consecutive days. (2) Whenever any well is abandoned, it shall be the obligation of the operator to plug such well in accordance with the rules of the Railroad Commission and this section. The operator shall submit to the superintendent's office twenty-four (24) hours in advance of the plugging operation an application for a permit which shall include a notice of intent of plug and abandon a description of the abandonment program and the filing fee. Whenever a drilling or reworking operation has just been completed on a well and the operator desires to plug and abandon such well, the twenty-four (24) hour notice shall be reduced to no less than a two (2) hour notice. The abandonment operations shall be conducted in such a manner to prevent well fluids from reaching the surface or contaminating subsurface fresh water zones. (3) Where enough of the producing or protective casing, has been removed from the well to expose the shoe of the surface casing, then a two hundred (200) foot cement plug shall be placed opposite the shoe of the surface casing to extend at least one hundred (100) feet downward and a similar one hundred (100) feet upwards from the shoe of the surface casing. Sufficient time shall be allowed for this cement to harden enough so that it will sustain the weight of drill pipe or tubing to this depth. The operator shall feel for the top of the plug to determine that the top is at least one hundred (100) feet above the shoe of the surface casing and is of sufficient hardness to hold the weight of the drill pipe or tubing to this depth. If a mechanical bridge plug or cement retainer is used in the middle of the cement plug, it will not be required to feel for the top of the plug. In the event the top of the plug is not one hundred (100) feet upwards from the shoe, then a second cement application will be required and tested as above. After the plug at the shoe has been successfully completed, then a minimum fifty (50) foot cement plug shall be set at the surface, after which the casing shall be cut off a minimum of five (5) feet below the surface of the ground and a one-half (½) inch steel plate welded over the top. The location shall then be backfilled and leveled. (4) Where the protective or producing string of casing to be left in the well extends upwards from the shoe of the surface casing so as to prevent the above described method of abandonment, then the following procedure will be used. A packer or cast iron cement retainer shall be set in the surface casing fifty (50) feet above the top of any other casing within the surface casing and sufficient cement shall then be squeezed below the packer or retainer to theoretically extend to one hundred (100) feet below the shoe of the surface casing and fill that portion up to the packer or retainer with the cement. The packer or retainer will be left in the well. If cement cannot be pumped into the annulus, the well shall be cemented in accordance with R.R.C. rules. (5) When casing is to be shot or cut off and pulled, a blowout preventer equipped to completely blank off the well bore and close off around the casing to be pulled shall be installed and tested prior to shooting or cutting off the casing. (6) In all cases prior to cutting any casing, the annulus between the casing to be recovered and the surface string of casing will be tested to determine whether this annulus is dead or pressured. In the event it is pressured then no casing will be recovered until this pressure is released to zero and the annulus filled with mud laden fluid of sufficient density to maintain zero surface pressure. (7) The well shall have a safety valve installed on the top of the casing string before any casing is shot or cut off. This safety valve shall not be removed until the first joint of casing has been pulled and shall then be kept immediately at hand so that it may be, if needed, reinstalled. (8) The well shall be completely filled at all times with mud laden fluid of sufficient density to prevent the entrance of formation fluids which would jeopardize well control during all casing and tubing operations. Periodic checks will be made of the mud fluid during displacing operations. (9) The operator shall have a responsible representative at the well during the setting and tagging of cement plugs and during the casing pulling operations, to ensure that the procedures outlined in the "Notice of Intent to Plug and Abandon" filed with the Railroad Commission are complied with and to ensure that other provisions of this article are complied with. (10) The superintendent shall inspect all abandoned and plugged wells for compliance with these requirements. No operator's bond shall be released unless the superintendent has issued a certificate of inspection.
Ask a question about Laredo law
Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.