For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24-73.15 — OPERATIONS MANAGEMENT

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-73.15

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/03f94545-16e5-45fd-b8ec-96e00c1fa584

Section 24-73.15 - OPERATIONS MANAGEMENT

(1) Well control. In the event of the loss of control of any well, the operator shall immediately take all reasonable steps to regain control of such well, regardless of any other provisions of this article and shall notify the superintendent by telephone and in writing as soon as practicable after receipt of notice of the occurrence of such loss of well control endangering persons or property. If and when the superintendent certifies in writing to the City Secretary that in his opinion: (a) Danger to persons or property exists because of such loss of well control, briefly describing the same, and (b) The operator is not taking, or is unable to take, reasonable necessary steps to regain control of such well; The operator shall employ any well control expert or experts or other contractors or suppliers of special services, necessary to regain control of such well. (2) Relief wells. (a) Drilling of a relief well may be commenced without first securing a permit if such action is deemed necessary in the good faith opinion of the operator. The operator shall make all reasonable efforts to notify the superintendent by telephone as soon as feasible, but failure to make such notification shall not be deemed a violation of this article. Within twenty-four (24) hours thereafter, the operator drilling the same shall notify the superintendent that such operations have been commenced, stating fully the reasons therefore, and shall within five (5) days after commencement of operations make application to the superintendent for a special permit to drill such well as a "relief well." (b) No filing fee is required for a "relief well" permit, but the operator drilling such relief well shall furnish the superintendent any information with respect to such relief well as may be requested from time to time by the council or the superintendent. No such well drilled as a relief well under the provisions of this section shall be completed as a producing well unless a permit therefore shall have been issued in the same manner as is required for the drilling of any other well. A "relief well" permit will be for a six (6) months' period only, and any relief well not completed as a producing well shall be plugged and abandoned within six (6) months after commencement of drilling operations, unless an extension is granted by the City Council. (3) Pipelines. Before any excavation or construction work is commenced on any pipeline to move oil, gas, water or other product to or from any well site, on, over, under, along or across any City street, sidewalk, alley or other City property, a franchise shall first be obtained from the City Council. All pipelines shall be laid only in accordance with the provisions of such franchise, this Code, the City Charter and other ordinances of the City. Before a franchise is obtained from the City Council, the parties requesting such franchise shall present information to the City pertaining to the safety equipment to be used in the pipeline, the type of pipe to be used, and how the same compares to state and federal regulations for similar type pipelines to be operated within a City. All permanent pipelines, shall meet A.S.A. 331.8 specification or better. Any operator constructing a pipeline shall furnish the superintendent a centerline description plat showing the proposed and as-built location and size of such pipeline. No operator shall interfere with or damage any existing storm sewer, drainage facility, water line, sewer line or gas line, or facility of a public utility located on, under or across the course of any such pipeline. Temporary lines may be laid under revocable easements. (4) Storage facilities. Steel storage tanks shall be used for the storage of liquid hydrocarbons and shall be constructed, installed and maintained in a good and workmanlike manner. All such steel tanks shall meet the minimum quality and design standards of API 12B standard bolted steel tanks or API 12D standard welded steel tanks including recommended pressure and vacuum relief valves. All such tanks shall be equipped with a vent line and at the point where gas is vented to the atmosphere from such vent line a flame arrester shall be installed. Each tank or tank battery shall be surrounded by an earthen fire wall located at such a distance from the tanks and of sufficient height to hold and retain at least one and one-half (1½) times the maximum capacity of such storage facilities. An operator may use, construct and operate steel conventional separators and such other appurtenances as are reasonably necessary for treating oil, condensate, or gas at each tank battery location. Such facilities shall be constructed and maintained so as to meet or exceed API standards. All pressure vessels shall be equipped with both a regulation pressure relief safety valve and a bursting head. (5) Fired vessels. No fired vessel or open flame shall be located nearer than one hundred and fifty (150) feet from any well or storage tank. (6) Fences. Within sixty (60) days of completion of drilling, redrilling, reworking or converting, or activation of an idle well, drill sites are to be secured from unauthorized entry by appropriate means which may include gate guards or a cyclone fence of heavy gauge. The entry gates shall be of galvanized steel, and shall be kept locked. All wells and production facilities shall be adequately protected by a cyclone type fence of heavy gauge wire, at least seven (7) feet tall with an eighteen (18) inch or longer barbed wire apron around the top, with the fence and apron extended over entry gates. The entry gates shall be galvanized steel and cyclone-type mesh, and shall be kept locked to prevent unauthorized entry. Flashing red warning lights shall be installed as requested by the superintendent on the tank battery sites. Safety precautions normally taken by reasonably prudent operators shall be observed. The final design of the fence around the wells and production facilities shall be approved by the superintendent. (7) Pumping unit prime movers. Only electric prime movers shall be permitted for the purpose of pumping wells. (8) Vented gas. No operator shall allow gas to escape or be vented into the air except for bleed gas normally vented from standard gas flow controls and normal stock tank vapors. All gas burned shall be burned in a manner which does not create or constitute a fire hazard and the location of the torch, pipe or other burning device, the construction thereof, the maintenance thereof, and the operation thereof shall at all times be in full compliance with such regulations as may be from time to time issued by the City. (9) Salt water and waste water disposal. All salt water produced from any oil or gas well shall be disposed of in accord with the requirements of the Texas Railroad Commission. No person shall permit any crude oil, gas or other flammable petroleum product to spill over, overflow, leak, drain out, escape or accumulate in any sewer or about the premises, or on any surface, or in any open surface ditch or any other exposed surface conduit, or handle any hydrocarbon in any manner or amount which creates a potential fire hazard, or permit any condition which may pollute any surface or subsurface water or damage any publicly owned land. (10) Production equipment. The operator shall maintain all production equipment in good condition. (11) Premises to be kept clean. All surface areas utilized by an operator for production facilities shall be kept clear of dry grass, weeds and combustible trash or other rubbish or debris that would, if allowed to accumulate, result in a fire hazard. In the event the operator does not keep the premises clean, the superintendent may have it contracted and the payment of such work performed shall constitute a valid lien against the property. (12) Signs. Printed signs with at least two (2) inch letters reading: "DANGER, NO SMOKING OR OPEN FLAMES ALLOWED," or similar words, and in Spanish "PELIGRO, NO FUMAR, MATERIAL COMBUSTIBLE," or similar words: Shall be posted in conspicuous places on each well, storage tank or battery of tanks. The signs shall include well name, drilling block number, R.R.C. identification number, twenty-four (24) hour emergency telephone number, and notification telephone number of the Laredo Fire Department. Well and lease designations required by the Railroad Commission or any other governmental authority having jurisdiction shall also be displayed. (13) Blocking of streets and alleys. No street or alley shall be blocked or obstructed by any drilling or producing operations unless prior consent is obtained from the City, except in connection with emergency operations being conducted under or pursuant to Sections 22-81 and 22-82.

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.