For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-23 — Definitions

Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 21-23

Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/735a1ef0-8175-4308-830d-ed45882c4d10

Sec. 21-23. - Definitions.

For the purpose of this division, the following definitions shall apply unless the context clearly indicates or requires a different meaning. Other technical terms used shall have the meanings or definitions listed in the most current edition of the Manual of Cross-Connection Control published by the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California, a copy of which is on file in the office of the city secretary, or in the most current edition of the Recommended Practice for Backflow Prevention and Cross-Connection Control Manual M14 published by the American Water Works Association. In any case where provisions of these manuals are in conflict, the most current edition of the Manual of Cross-Connection Control shall prevail. Air gap separation (AG) as defined by the Texas Commission on Environmental Quality, means the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying water to a tank, fixture, receptor, sink, or other assembly and the flood level rim of the receptacle. The vertical, physical separation must be at least twice the diameter of the water supply outlet, but never less than one (1) inch. Atmospheric vacuum breaker (AVB) means an assembly containing a float check, a check seat, and an air inlet port. Auxiliary water supply means any water supply other than the City of Plano's approved public water supply, including water from another public water supply or from a natural source including, but not limited to, wells, cisterns, springs, rivers, streams, used waters, or industrial fluids. Backflow means the reversal of flow of water or mixtures of water and other liquids, gases or other substances into the distribution pipes of a potable water supply from any sources other than the City of Plano water system. Backflow prevention assembly means an assembly which, when properly installed between the city water supply system and the terminus or point of ultimate use, will prevent backflow. Examples of such assemblies include, but are not limited to, reduced pressure backflow assemblies, double check valve assemblies, pressure vacuum breakers, and spill resistant vacuum breakers. Backflow prevention assembly tester (BPAT) means an individual licensed in accordance with Texas Commission on Environmental Quality rules to test backflow prevention assemblies. Backflow program administrator means a third-party who assists the City of Plano with managing the backflow assemblies and associated records. Backpressure means any elevation of pressure in the downstream piping system (including by pump, elevation of piping, or steam and/or air pressure) above the supply pressure at the point of consideration which would cause, or tend to cause, a reversal of the normal direction of flow. Back siphonage means a form of backflow caused by a reduction in system pressure resulting in the existence of a negative or sub-atmospheric pressure at a site in the water system. Building official means the building official of the City of Plano or the building official's designee. City means the City of Plano, Texas, and its duly authorized representatives. Closed system means a piping system that has no space for water to expand. Commission means the Texas Commission on Environmental Quality ("TCEQ"). Contamination means an impairment of the quality of the public potable water supply or a private potable water supply by the introduction or admission of any foreign substance that degrades the quality and which creates an actual hazard to the public health through poisoning or through the spread of disease by sewage, industrial fluids, waste, or other hazardous product or material. Cross-connection means any actual or potential connection or structural arrangement between a public or consumer's potable water system and any other source or system through which it is possible to introduce into any part of the potable system any used water, industrial fluid, gas, or substance other than the intended potable water with which the system is supplied. Bypass arrangements, jumper connections, removable sections, swivel or change-over devices and other temporary or permanent devices through which or because of which backflow can occur are considered to be cross-connections. Customer means a person, company, or entity contracting with the city to receive potable water service. Customer's potable water system means that portion of the privately owned potable water system lying between the service connection and the point of use by customer. This system includes, but is not limited to, all pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, store, or utilize the potable water. Degree of hazard means either a non-health or health hazard and is determined by the evaluation of the conditions within a system by the superintendent, director, the city's environmental health and sustainability department, or the building official. Director means the director of the city's public works department. Double check valve assembly (DC) means an assembly composed of two (2) independently acting approved check valves, including tightly closing resilient-seated shutoff valves, attached at each end of the assembly and fitted with four (4) properly located resilient-seated test cocks. Health hazard means a cross-connection, potential cross-connection, or other situation involving any substance that could cause death, illness, spread of disease, or has a high probability of causing such effects if introduced into the potable drinking water supply. Industrial fluids means any fluid or solution which may be chemically, biologically, or otherwise contaminated or polluted in a form or concentration which would constitute a health, system, pollutional, or plumbing hazard if introduced into an approved water supply. Examples of industrial fluids include, but are not limited to: polluted or contaminated used water; all types of process waters and used waters originating from the public potable water system which may deteriorate in sanitary quality; chemicals in fluid form; plating acids and alkalis; circulated cooling waters connected to an open cooling tower and/or cooling waters that are chemically or biologically treated or stabilized with toxic substances; contaminated natural waters such as form wells, springs, streams, rivers, bays, harbors, seas, irrigation canals or systems, etc.; and oils, gases, glycerin, paraffins, caustic and acid solutions and other liquid and gaseous fluids used industrially, for other processes, or for firefighting purposes. Material reporting deficiencies shall mean inaccurate or incomplete reporting as required in the approved city backflow prevention assembly test report. Nonhealth hazard means a cross-connection or potential cross-connection involving any substance that generally would not be a health hazard but would constitute a nuisance, or be aesthetically objectionable, if introduced into the potable water supply. Non-potable water means a water supply which has not been approved for human consumption by the commission. Person means any individual or any association, firm, partnership, joint venture, corporation or other legally recognized entity, whether for profit or not for profit. Plano backflow prevention assembly tester (Plano BPAT) means an individual licensed in accordance with TCEQ rules and registered with the city for the purpose of testing backflow prevention assemblies. Plumbing hazard means an internal or plumbing type cross-connection in a customer's potable water system that may be either a pollutional or a contamination type hazard, including, but not limited to, cross-connections to toilets, sinks, lavatories, wash trays, water filtration systems and lawn sprinkling systems. Pollution means an impairment of the quality of the public potable water supply to a degree which does not create a hazard to the public health but does adversely and unreasonably affect the aesthetic qualities of such water for domestic use. Potable water means any public water supply which has been investigated and approved by the commission as satisfactory for drinking, culinary and domestic purposes. Premises or property means any property real, improved or personal that is connected to the city water system. Pressure vacuum breaker (PVB) means an assembly which contains an independently operating internally loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check valve with properly located resilient-seated test cocks and tightly closing resilient-seated shutoff valves attached at each end of the assembly. Process waters means water used to cool any operation or manufacturing process. Public potable water supply means any publicly or privately owned water system operated as a public utility under a health permit to supply water for domestic purposes. Such a system includes all sources, facilities and appurtenances between the source and the point of delivery such as valves, pumps, pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, treat, or store potable water for public consumption or use. Pressure loss means any reduction in the water pressure supplied by the city. Reduced pressure backflow prevention assembly (RP) means an assembly containing two (2) independently acting approved check valves together with a hydraulically operating, mechanically independent pressure differential relief valve located between the check valves and at the same time below the first check valve. The assembly includes four (4) properly located resilient-seated test cocks and two (2) tightly-closing resilient-seated shutoff valves at each end of the assembly. Service connection means the terminal end of a service connection from the public potable water system (i.e., where the utility loses jurisdiction and sanitary control over the water at its point of delivery to the customer's water system). If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. Spill-resistant pressure vacuum breaker (SVB) means an assembly which contains an independently operating internally loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check valve, with properly located resilient seated test cock, a properly located bleed/vent valve and tightly closing resilient seated shutoff valves attached at each end of the assembly. Superintendent means the superintendent for the city designated by the director to oversee the cross-connection control program or the superintendent's designee. Supply pressure means the existing pressure in the city water system. Thermal expansion means heated water that does not have any space to expand. Used water means any water supplied by the utility from a public water system to a customer's water system after passing through the service connection and which is no longer controlled by the utility. Utility means the division in city's public works department overseeing the cross-connection control program.

(Ord. No. 2011-12-2, § II, 12-12-11; Ord. No. 2022-1-4, § II, 1-10-22)

Ask a question about Plano law

Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.