§ 21-28 — Inspection, testing and registration of backflow prevention assemblies
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 21-28
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/bf7a5f4c-0901-4557-b7b0-0e8686db5ee7
Sec. 21-28. - Inspection, testing and registration of backflow prevention assemblies.
(a) Testing of backflow prevention assemblies. The owner, occupant, manager, other person in control of any premises or the person responsible for the maintenance of the property on which, or on account of which, backflow prevention assemblies are installed, shall have the assemblies tested by a Plano BPAT. Backflow prevention assemblies shall be tested annually and shall also be tested immediately after installation, relocation, repair or work performed upstream of the assembly. However, more frequent testing may be required if notice is provided by the city to the owner, occupant, manager, other person in control of the premises or the person responsible for the maintenance of the property. Should the city provide written notice that more frequent testing is required, the owner, occupant, manager, other person in control of the premises or the person responsible for the maintenance of the property shall provide the testing as required by the written notice. (b) Report of backflow prevention assembly test. An approved city backflow prevention assembly test report shall be completed by a Plano BPAT on each backflow prevention assembly tested. Each completed test report with records of tests, repairs, or replacement, shall be submitted to the backflow program administrator within ten (10) calendar days after the testing, repair, replacement or work performed upstream of the assembly. A copy of the completed test report shall be left on-site with the property owner, occupant, manager or other person in control of any premises or the person responsible for the maintenance of the property. (c) Test results. Test results for a reduced pressure backflow prevention assembly shall provide a reading for both checks. Once it has been determined that the second check has closed tight above the relief valve opening point, record the reading of the gauge as the second check reading. Only backflow prevention assembly field test procedures approved by the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research will be accepted. If an assembly fails, the Plano BPAT shall immediately notify the superintendent in person or by phone during regular business hours of the public works department. If an assembly failure occurs at any time other than regular business hours, the Plano BPAT shall notify the superintendent on the next regular business day. Upon notification to the superintendent of assembly failure, the superintendent will notify the owner, occupant, manager or other person in control of any premises or the person responsible for the maintenance of the property of the time period that they have to repair or replace the assembly. The assembly shall be replaced or repaired within the time period set by the superintendent or within five (5) calendar days from the date of assembly failure whichever date is sooner. In the event of assembly failure, water service shall not be connected or restored until the assembly has been repaired or replaced and passes a retest unless written authorization is given by the superintendent that water service is authorized to be connected or restored at an earlier date. (d) Registration and maintenance of backflow prevention assemblies. (1) Each backflow prevention assembly located on property subject to this division shall be registered with the utility through the submittal of a completed form approved by TCEQ to the backflow program administrator. (2) The owner, occupant, manager, other person in control of the property or the person responsible for the maintenance of the property is responsible for general maintenance and upkeep of all approved backflow prevention assemblies located thereon. (3) Backflow prevention assemblies shall be tested, repaired, and/or replaced at the expense of the owner, occupant, manager, other person in control of the property or the person responsible for the maintenance of the property whenever such assemblies are determined to be defective by the superintendent or building official. An assembly is defective if it cannot be identified through the manufacturer's serial number and/or is not a properly installed backflow prevention assembly as required by this division. (e) New plumbing or plumbing modifications. The building official or superintendent shall inspect all new backflow prevention assembly installations, which are subject to this division and are required by application for a plumbing permit. A service inspection certification form shall be completed by the building official or superintendent on each new plumbing installation or on plumbing modifications. Each completed form shall be received by the utility within ten (10) days after the inspection. (f) Existing properties. The superintendent shall inspect all existing properties connected to the potable water system for the purpose of determining whether a cross-connection exists and what type of backflow prevention assembly should be installed pursuant to this division. (g) Existing backflow prevention assemblies. Properties with existing backflow prevention assemblies installed in their system, which have not been registered with the superintendent, as of the effective date of this division shall come into compliance with the provisions of this division within sixty (60) days of notification unless the superintendent finds a health hazard exists in which case the superintendent shall determine the appropriate time of compliance. (h) Existing assemblies in compliance. The owner, occupant, manager or other person in control of any premises or the person responsible for the maintenance of a property with existing assemblies, which comply with the provisions of this division, shall provide written proof that each such assembly has been properly maintained and serviced by a Plano BPAT. If maintenance and service records are not available, the assembly shall be tested in accordance with the requirements of this division. (i) Replacement. If the assembly is not capable of being tested, identified or cannot be repaired, it must be replaced with an approved assembly in accordance with the requirements of this division. (j) Testing fee. A thirty-five dollar ($35.00) fee shall be submitted to the backflow program administrator for each backflow prevention assembly tested and shall be paid at the time that the Plano BPAT files the backflow prevention assembly test report with the city. (k) Retesting fee. A twenty-five dollar ($25.00) fee shall be submitted to the city for each backflow prevention assembly that is required to be retested due to a deficiency or a violation of this division including, an invalid test report, or one (1) of the following: (1) Falsification of backflow prevention assembly test report. (2) Incorrect serial number. (3) Blank or incomplete information fields on backflow prevention assembly test report. (4) Plano BPAT's test gauges are not registered with the city. (5) Duplicate serial number on multiple backflow prevention assembly test report. (6) Performing a backflow prevention assembly test using unapproved testing procedures. (7) Inappropriate registration with the city. (8) BPAT is not registered with the utility at the time the test(s) was performed. (l) Retest procedure. The retest(s) shall be performed in the presence of the superintendent. The fee shall be paid to the city prior to the retest(s) being performed and the retest(s) shall be completed within five (5) business days from first notification. Any retest(s) required shall be performed by the Plano BPAT or BPAT who is responsible for the deficiency or violation unless the Plano BPAT or BPAT has resigned or lost their testing privileges. All retest(s) should be performed during normal city business hours. (m) Exemption. Atmospheric vacuum breakers are exempt from this section.
(Ord. No. 2011-12-2, § II, 12-12-11; Ord. No. 2022-1-4, § II, 1-10-22)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.