§ 21-26 — Type of backflow prevention assembly required
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 21-26
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/eb0e621a-8a3a-4d0c-a16e-eaea96e3e0be
Sec. 21-26. - Type of backflow prevention assembly required.
(a) The type of backflow prevention assembly required shall be commensurate with the type of hazard that exists on the customer's premises. The minimum types of backflow prevention assemblies required to protect the city's potable water supply are set forth in table 1, below. However, the water user may choose a higher level of protection than required by the city. All backflow prevention assemblies shall be from an approved list from the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research. Situations which are not covered in table 1 shall be evaluated on a case by case basis, and the required backflow prevention assembly shall be determined by the superintendent. (b) Containment and/or secondary protection may be required on certain health hazard installations in accordance with the following table 2, in addition to any other protection, identified herein, which is required to isolate equipment within a facility. The superintendent or building official may require backflow prevention assembly to be installed on other facilities with a similar degree of hazard in accordance with the plumbing code of the City of Plano, as amended, or other applicable law. These backflow prevention assemblies shall be installed in the main service line on the building side of the meter or the principle branch serving a single tenant space. The location of the backflow prevention assembly shall be approved by the superintendent or building official in accordance with the provisions contained in section 21-28. (c) The building official, the city's fire chief and the director may approve a variance to these requirements for backflow on fire sprinkler systems. Table 1 Type of Hazard | Minimum Type of Backflow Prevention Assembly Commercial fire protection systems utilizing chemicals or additives (new installations or remodels of existing systems) | RP—UL or FM and USC approved assemblies only Commercial fire sprinkler systems without chemicals or additives (all new installations or remodeling of existing systems, after March 1, 2014, with a cumulative total of fifty (50) or more head changes (additions and/or relocates) or cumulative remodeling of ten thousand (10,000) or more square feet of floor space in a building during the life of the sprinkler system) | DC—UL or FM and USC approved assemblies only Residential, single-family fire sprinkler systems (new installations or remodels of existing systems) | DC-USC approved assemblies only (two (2) inches or smaller) DC—UL or FM and USC approved assemblies only (larger than two (2) inches) Commercial and residential landscape irrigation systems utilizing chemical additives or quick coupler hose connections | RP or AG only Stationary construction fire hydrant meters | RP or AG immediately adjacent to meter and one-way check valve on discharge lines on trucks Temporary construction fire hydrant meters | RP or AG in fill line on the water hauling equipment and one-way check valve on discharge lines on trucks Premises where any customer purchasing water for the purpose of resale or distribution | RP or AG at each service connection Premises owned by any state, federal, or foreign government or agency | RP or AG at each service connection Premises where there is a history of cross-connections being established or re-established | RP or AG Animal watering sites | AG or RP or PVB or SVB. PVB or SVB not approved where backpressure situations exist Non-health hazard | DC, PVB, SVB or RP at point of connection to hazard or at service connection prior to first branch line off customer's service line. PVB or SVB not approved where backpressure situations exist Health hazard | AG, PVB, SVB or RP at point of connection to hazard and/or at service connection prior to first branch line off customer's service line. PVB or SVB not approved where backpressure situations exist Carbonated drink machines | RP—Assembly and all downstream piping shall be non-corrosive when in contact with CO2 gas Table 2 Health Hazard Installations TYPE OF BACKFLOW PREVENTION ASSEMBLY REQUIRED Breweries | RP Carwash | RP Dairies | RP Multi-story building three (3) floors or more | RP Animal hospital | RP Auxiliary water supply | RP Building containing a reclaimed water system | RP Chillers | RP Commercial laundry | RP Cooling towers | RP Dental office | RP Doctor's office | RP Food and beverage processing plants | RP Funeral home and mortuary | RP Green house or nursery (with toxic chemicals) | RP Hospitals (parallel system required) | RP Laboratories (including medical, dental and research labs, and labs at educational facilities) | RP Manufacturing plant | RP Meat processing plant | RP Metal manufacturing, cleaning, processing and fabrication plants | RP Micro chip fabrication facilities | RP Petroleum processing or storage facilities | RP Photo and film processing | RP Plants using radioactive materials | RP Plating or chemical plants | RP Premises where inspection is restricted or exempted | RP Private/individual unmonitored wells | RP Rainwater harvesting systems | RP Rendering plant | RP Sewage lift stations | RP Sewage treatment plants | RP Steam plants | RP Space heating boilers | RP
(Ord. No. 2011-12-2, § II, 12-12-11; Ord. No. 2014-2-10, § I, 2-24-14; Ord. No. 2022-1-4, § II, 1-10-22)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.