§ 21-27 — Backflow prevention assembly installation requirements
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 21-27
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/8ade4e1e-0dc6-4c76-bfab-6cfc280a5488
Sec. 21-27. - Backflow prevention assembly installation requirements.
(a) Installation requirements. All new, replacement, or reconditioned backflow prevention assemblies shall be installed in accordance with the International Plumbing Code, as adopted and amended by the City of Plano and with the following standards, unless otherwise directed or approved by the superintendent. (1) Plumbing permit required. Prior to the installation, relocation or replacement of a backflow assembly, a plumbing permit must be obtained from the building inspection department of the city. (2) Installation. The assembly shall not be located in the same vault or meter box with the city's water meter. Backflow assemblies and components shall not be installed within three (3) feet of a water meter box or vault. All backflow assembly installation shall be done in accordance to the approval set forth in the list of approved backflow prevention assemblies issued by the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research, a copy of which is on file in the city public works department. If installed in a structure all backflow assemblies must be easily accessible for testing, repair or replacement. (3) Location. The owner or occupant must prove to the city that no connections or tees are located between the meter and the backflow prevention assembly. The relief valve discharge on a reduced pressure backflow assembly (RP) shall not be solidly piped into a sump, sewer, drainage ditch, etc. Test cocks shall not be used as supply connections. (4) Air gap separation (AG). All piping from the service connection to the receiving tank shall be above grade and be entirely visible. No water use shall be provided from any point between the service connection and the air gap separation. The water inlet piping shall terminate at a distance of at least two (2) pipe diameters of the supply inlet, but in no case less than one (1) inch above the overflow rim of the receiving tank. (5) Reduced pressure backflow assemblies (RP). Reduced pressure backflow assemblies shall be installed above ground level and shall be placed a minimum of twelve (12) inches above the finished grade, no higher than five (5) feet, and accessible for testing and repair. A freeze-proof enclosure with a concrete slab at finished grade is recommended. Where it is impractical to install the assembly outside, the installation may be made inside the building in an area not susceptible to flooding. Proper free flowing/gravity drainage must be provided for the relief valve. If the drain line is to drain outside, then the termination point must be a minimum of twelve (12) inches above finished grade. (6) Double check valve assemblies (DC). Double check valve assemblies can be installed above finished grade in a freeze-proof enclosure or below grade in a vault. If assembly is installed below grade the test cocks must be plugged with corrosion resistant watertight plugs. Assembly may not be installed more than five (5) feet above the finished grade. (7) Bypass. If a bypass is installed around any approved backflow prevention assembly, the bypass must be protected from backflow/backpressure with the same type of backflow prevention assembly that it has bypassed. The backflow prevention assembly on the bypass must be installed according to the same requirements as the service line assembly. (8) Thermal expansion. The installation of a backflow assembly may create a closed system which may result in thermal expansion. It is the responsibility of the owner, occupant, manager, other person in control of any premises or the person responsible for the maintenance of a property to address the possibility of thermal expansion due to the required installation of backflow assemblies creating a closed system. (b) Lost pressure. The city is not responsible for any pressure loss created by the installation of a backflow assembly.
(Ord. No. 2011-12-2, § II, 12-12-11; Ord. No. 2022-1-4, § II, 1-10-22)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.