§ 31-602 — DESIGN STANDARDS
Code of Ordinances of the City of Suffolk, Virginia (Codified through Ordinance No. 26-O-074, enacted June 17, 2026 (Supp. No. 55)) · Suffolk Unified Development Ordinance § 31-602
Corpus is an independent public-information project, not the official City of Suffolk website. Stable reference: corpuslaw.us/code/a5604ef0-c3cd-4799-add0-ac12567faf4c
SEC. 31-602. - DESIGN STANDARDS.
(a) PURPOSE. These criteria are intended to assist in focusing design principles in order to preserve property values, promote the public health, safety and general welfare, and develop a satisfactory visual appearance within the City. The following standards regulate the use of land, buildings, structures and other premises, as authorized by Code of Virginia, § 15.2-2280. The purpose of these regulations is to promote the health, safety or general welfare of the public and of further accomplishing the objectives of Code of Virginia, § 15.2-2200; to implement the Comprehensive Plan, to provide for adequate light, air, convenience of access, and safety from fire, flood, crime and other dangers; to reduce or prevent congestion in the public streets by providing a streetscape conducive to pedestrian movement; to facilitate the creation of a convenient, attractive and harmonious community; and to protect against the overcrowding of land; and to encourage economic development activities that provide desirable employment and enlarge the tax base by providing for a quality housing stock; and to promote affordable housing by permitting creative alternatives relating to site design which can achieve savings in the installation of project infrastructure. These criteria implement the Comprehensive Plan. Unless otherwise specified in this Ordinance, this Section is applicable to all residential, commercial and industrial zoning districts in the City of Suffolk. These criteria are designed to ensure that the man-made elements of a site design are carefully crafted to facilitate the safety of pedestrian activity, to provide for communities which are walkable, and to promote a sense of community. It is not the intent of this Section to deny or to condition applications for development approval primarily on the basis of aesthetics, or to regulate the materials, colors, texture, or light reflecting characteristics of buildings. This Section does encourage, but does not require, materials, colors, texture, or light reflecting characteristics which add to the character of the community and enhance the appearance of buildings and structures. Where any requirement of this Section regulates a matter which is regulated by the Uniform Statewide Building Code (USBC), and the requirement of this Section is in conflict with the USBC requirement and cannot reasonably be conformed to it, the USBC shall govern. (b) GENERAL REQUIREMENTS. Except as otherwise indicated or where indicated as being optional or recommended, the following requirements shall apply within all zoning districts: (1) INTERPRETATION. Terms and phrases used herein shall be construed in accordance with Francis D.K. Ching, A Visual Dictionary of Architecture; (Van Nostrand Reinhold, 1995), at 52-59, which publication is hereby incorporated by reference as if set forth in its entirety herein. (2) MECHANICAL EQUIPMENT. Mechanical equipment, whether ground level, wall mounted, or roof mounted, shall be screened from public view and designed to appear as an integral part of the building. Electrical meters and service components and similar utility devices shall be out of view from public right-of-ways. (3) MASSING. For the CBD, VC, RM, RC and RU districts, the massing of buildings shall be compatible with buildings on adjacent lots and parcels. The massing of a building shall be considered compatible if not less than six (6) of the below-referenced elements are provided in a manner consistent with any applicable requirements of this Section: • Building Silhouette. Buildings maintain a similar pitch and scale with different roof line configurations. • Spacing Between Building Facades. A narrow setback (not less than ten or more than 70 feet) is provided between building facades facing the public right-of-way in order to frame the structure. • Setback from Property Line. The building contains bays or courtyards projecting outward from the building facade. • Proportion of Windows, Bays, and Doorways. Windows, doorways, bays, and pediments meet the following criteria: (1) windows, doorways, bays, and pediments do not vary more than ten percent (10%) in size from windows, doorways, bays, and pediments in the facade of adjacent buildings on the site, and (2) vertical or horizontal elements tied together in bands across facade lengths. • Proportion of Primary Facade. The size of facades facing the public right-of-way is similar in area and height to width ratios. The size of the facade shall be considered "similar" if the largest facade does not vary more than thirty percent (30%) in size from the smallest facade. • Location and Treatment of Entryway. In order to create visual commonality between structures, the following criteria shall apply: (1) the size of entryways in building facades facing the public right-of-way shall not vary by more than thirty percent (30%) in size, and (2) entryways for adjacent buildings shall not vary more than thirty percent (30%) from grade, as measured from the ground floor elevation. • Exterior Materials Used. Applicants are encouraged to provide similar materials and treatment on the exterior walls of each building, which add detail and monumentality to a building. • Building Scale. Building height and configuration shall not vary by more than ten percent (10%), unless needed to maintain continuity between the ground floor elevation of adjoining buildings on the site. • Landscaping. Similar types and densities (varying by not more than thirty percent (30%) of plantings adjoin the front facade in order to tie together buildings and to define space. • Shadow Patterns. Applicants are encouraged to adjust the light and dark surfaces from materials used and projections form windows, bays and setbacks to create a vertical, linear edge on adjoining buildings. EXAMPLES OF DESIGN ELEMENTS [image omitted; see the official code] (4) BLANK WALLS. A. The purpose of this Section is to avoid long, monotonous, uninterrupted windowless walls or roof planes. Such walls discourage pedestrian activity. This Section shall apply within each zoning district set forth in Subsection B, below, and to multiple-family dwellings. B. Building wall offsets, including projections, recesses and changes in floor level as provided in this Subsection shall be used in order to add architectural interest and variety, and to relieve the visual effect of a simple, long wall for the zoning districts listed below. [image omitted; see the official code] Example of articulation of blank walls. Source:Anton Nelessen, Visions for a New American Dream (Chicago: American Planning Association, 1993). Reprinted with permission from American Planning Association. Applicants are also encouraged to provide roof-line offsets in order to provide architectural interest and variety to the massing of a building and to relieve the effect of a single, long roof. Facades facing or adjoining the front setback which exceed the length set forth in Column (B), below, measured horizontally, shall incorporate wall plane projections or recesses having a depth of at least 3 percent of the length of the facade and extending at least 20 percent of the length of the facade. No uninterrupted length of any facade shall exceed 150 horizontal feet. Windows, awnings, entryways and/or arcades shall comprise not less than the percentage set forth in column (C), below, where the facade adjoins or faces the front setback. (A) ZONING DISTRICT | (B) >UNINTERRUPTED LENGTH | (C) PERCENT OPEN B-1* | 150 | 60% B-2* | 150 | 60% O-I/C-P | Not applicable | Not applicable CBD/VC | See Section 31-408(g), "Main Entrance," "First Floor Pedestrian Orientation, and "Entryways," and "Canopies and other Building Entrances." PD/TND | 150 | 60% RC/RU** *;hg;Applies only to buildings exceeding 30,000 square feet, or where the cumulative gross floor area of separate buildings on a site under common ownership exceeds 30,000 square feet. See Section 31-715 of this Ordinance. ** Applies only to multiple-family dwellings. C. Where the construction of a blank wall is necessitated by the Building Code, the wall should be articulated by the provision of blank window openings trimmed with frames, sills and lintels or, if the building is occupied by a commercial use, by using recessed or projecting display window cases. Intensive landscaping may also be appropriate in certain cases. (5) ENCLOSURE RATIO (OPTIONAL EXCEPT FOR CBD AND VC DISTRICTS). A. The Enclosure Ratio refers to the ratio of building height to spaces in front of the building. Buildings serve to spatially define streets. Proper spatial definition is achieved with buildings or other architectural elements (including certain tree plantings) that make up the street edges aligned in a disciplined manner with an appropriate ratio of height to width. The condition of alignment occurs when the facades of buildings cooperate to delineate the public space, as walls form a room. Building articulation must take place primarily in the vertical plane or facade. Appendages such as porches, balconies, and bay windows are encouraged to promote the visual transition. The condition of enclosure generated by the height-width ratio of the space is related to the physiology of the human eye. If the width of a public space is such that the cone of vision encompasses less street walls than the opening to the sky, then the degree of spatial enclosure is slight. Ratios not exceeding 1:4 are considered optimal, while a 1:6 height-to-width ratio is the absolute minimum required for appropriate urban spatial definition. See P. Craighead, ed., The Hidden Design in Land Use Ordinances (University of Southern Maine, 1991), at 45; r. Arendt, Rural by Design (American Planning Association, 1994), at 10-11. An appropriate average ratio is 1:3. As a general rule, the tighter the ratio, the stronger the sense of place. Spatial enclosure is particularly important for shopping streets, which must compete with malls which provide very effective spatial definition. In the absence of spatial definition by facades, disciplined tree planting is an alternative. Trees aligned for spatial enclosure are necessary along thoroughfares with substantial front yards. B. The height and/or setback of buildings facing across a public right-of-way shall be adjusted to conform to the maximum enclosure ratios as set forth in Column (B) below, as measured from the front facade of buildings facing across a public right-of-way. If Streetscape Landscaping is provided in accordance with Section 31-603(g)(2)B. of this Ordinance, the enclosure ratio shall be measured from the height of the trees at maturity rather than the height of the buildings, and shall conform to Column (C), below. For the internal streets or circulation systems of subdivision plats or site plans, the Enclosure Ratio shall be computed by dividing the height of the shortest facing structure by the spaces between the buildings. For development on individual tracts adjoining a public right-of-way and not under common ownership with tracts or parcels facing across the right-of-way, the Enclosure Ratio shall apply only to the tract or parcel subject to the application for development approval. EXAMPLE: A building (Building A) is 15 feet in height and faces a building (Building B) 24 feet in height across a street with a 40-foot right-of-way. Building A is located 15 feet and Building B is located 20 feet from the edge of the right-of-way, producing a building-to-building space of 75 feet. The Enclosure Ratio is 1:5 (15:75 1:5). See first "Village Scale" example, below; (A) ZONING DISTRICT(S) | (B) MINIMUM ENCLOSURE RATIO (BUILDINGS) | (C) MINIMUM ENCLOSURE RATIO (STREETSCAPE TREES) A, RR, RE* | 1:9 | 1:5 RL, RM, RLM* | 1:6 | 1:2 RC, RU* | 1:5 | 1:0.75 B-1, B-2* | >1:6 | 1:2 CBD, VC | 1:4 | 1:2 M-1, M-2, CP* | Not Applicable *Optional [image omitted; see the official code] Enclosure ratio examples Example of enclosure ratios. Source: P. Craighead, ed., The Hidden Design in Land Use Ordinances (University of Southern Maine, March 1999), at 45. Reprinted with permission from University of Southern Maine. (c) RESIDENTIAL DESIGN STANDARDS. (1) ATTACHED SINGLE-FAMILY. Attached single-family development shall be permitted in accordance with Section 31-406, subject to the following standards. A. LOT WIDTH. Attached housing is exempt from the lot width standard of the underlying zoning district, but is not exempt from minimum lot area requirements except as allowed by Section 31-407(d). B. SETBACKS. No interior side setback is required on the "attached" side of a lot containing an attached house. The front, side, and rear setback standards shall apply around the perimeter of any building which contains attached housing units. (2) MULTI-FAMILY DEVELOPMENT. The following standards shall apply to multi-family dwelling units: A. Multi-family buildings shall be separated by a minimum of 15 feet. B. Private open space. (i) A minimum of 200 square feet of usable common open space shall be provided for each multi-family dwelling unit to provide for active recreational needs of residents. Usable open space excludes parking areas, required landscape areas, land within a floodway, water bodies, and land with greater than 15-percent slope. Open space provided pursuant to this requirement shall be accessible to all residents of the development and shall measure at least thirty (30) feet across its narrowest dimension. (ii) The Administrator may waive up to fifty percent (50%) of the open space requirement if the development satisfies one of the following criteria. a. All units are located within 1,000 feet of a public park as measured along a public sidewalk, trail or bikeway; or b. The development includes active recreation amenities for residents such as pools, tennis courts or playgrounds. (iii) Private open space requirements for multi-family dwelling units in the CBD zoning district may be waived by the Director with documented proof that adequate amenities such as public parks, sidewalks, trails, or bikeways are within 1,000 feet of the development. (3) SINGLE-FAMILY DESIGN STANDARDS. The purpose of these provisions are: (1) to supplement the zoning regulations applied to site built, modular and manufactured homes with additional standards and procedures which will promote a satisfactory living environment for residents of single-family homes and which will permit a mix of homes and other types of housing within the City; (2) to permit greater diversity in the types of housing communities; (3) to ensure that all new single family dwellings are compatible with other forms of housing; (4) to ensure the provision of single-family housing opportunities for persons or families of low or moderate income by providing for design standards which ensure compatibility among various types of housing units as an alternative to exclusionary zoning. It is recommended that application for development approval for a single family home conform to the following standards and criteria: A. It is recommended that not less than sixteen percent (16%) of the total area of any front facade (excluding garage doors) shall consist of windows and doors. B. It is recommended that not less than eight percent (8%) of the total area of any side or rear facade shall consist of windows and doors. C. It is recommended that all residential structures shall be constructed on either a 16-inch raised slab above grade or a 20-inch crawl space. D. For major subdivisions, a customized entrance is provided at the entry street intersecting the arterial or major collector which features a waterfall, sculpture, monument signage, special landscaping, specialty pavement, or enhanced fence wall details. A boulevard median is required. (4) MANUFACTURED HOMES. Manufactured homes shall conform to the requirements of Subsection (c)(3) of this Section and to the following standards and criteria: A. Any manufactured home on an individual lot shall conform to the same building setback standards, side and rear yard requirements, standards for enclosures, access, vehicle parking, and square footage standards and requirements to which a conventional single-family residential dwelling on the same lot would be subject. B. The dwelling shall be attached to a permanent foundation system in compliance the International Conference of Building Officials "Guidelines for Manufactured Housing Installation," as may be amended, and the following requirements: (i) All wheels, hitches, axles, transporting lights and removable towing apparatus shall be permanently removed prior to installation of the dwelling unit. (ii) The foundation shall be excavated and shall have continuous skirting or backfill leaving no uncovered open areas excepting vents and crawl spaces. The foundation shall be exposed no more than 12 inches above grade. (iii) All manufactured homes shall be anchored to the ground by means of anchors attached both to the frame and with straps extending over the top and completely surrounding the sides and roof, consistent with Uniform Building Code guidelines. Anchor design shall be approved by the Administrator prior to installation and shall comply with all requirements of the State of Virginia. In addition, test data giving certified results of pull tests in soils representative of the area in which the anchors are to be used shall be submitted to the Administrator. Minimum load in direct pull shall be 5,400 pounds. Anchors shall be marked so that after installation, the identification is in plain view for inspection. C. For homes which are narrower than sixteen (16) feet in width, the unit shall be oriented on the lot so that its long axis is parallel to the street. (d) CBD AND VC ZONING DISTRICTS. (1) GENERALLY. New non-residential and residential structures in non-residential and mixed use districts are encouraged to conform to the City of Suffolk Urban Design Plan (July 1993), chapters IV and V, which document is hereby incorporated by reference and made a part of this Ordinance. (2) ROOFS. Permitted roof types and roof design shall be consistent with the Urban Design Plan. Gable roofs with a minimum pitch shall be used to the extent possible in the Town Center area. Flat roofs may be used within existing commercial blocks in the CBD or VC districts where consistent with the predominant style on the same block. Architectural elements that add visual interest to roofs, such as dormers, belvederes, masonry or brick chimneys, cupolas, clock towers and other similar elements are encouraged. See Figure 602-1. Figure 602-1 [image omitted; see the official code] Reprinted with permission from American Planning Association. A Nelessen, Visions for a New American dream (Chicago, American Planning Association, 2ed. 1994), at 337. (3) CORNER BUILDINGS. Commercial buildings on corner lots shall have at least two front facades visibly exposed to the street. Such buildings may be designed with an increase of not more than 15 percent in permissible height on the corner of the lot in order to accommodate corner towers. In the alternative, the front facade may be recessed in an inverted "L" shape in order to accommodate a courtyard. See Figure 602-2. Figure 602-2 [image omitted; see the official code] Corner building with courtyard | Corner buildings provide a gateway to a commercial center. Source: New Jersey State Development and Redevelopment Plan
(Ord. No. 18-O-091, § 2(Exh. B), 8-15-2018; Ord. No. 22-O-103, § 2(Exh. B), 9-21-2022)
Ask a question about Suffolk law
Corpus searches the Suffolk sections it holds and shows the ones that match, with their citations. Free, no sign-in.
