For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 31-604 — LIGHTING

Code of Ordinances of the City of Suffolk, Virginia (Codified through Ordinance No. 26-O-074, enacted June 17, 2026 (Supp. No. 55)) · Suffolk Unified Development Ordinance § 31-604

Corpus is an independent public-information project, not the official City of Suffolk website. Stable reference: corpuslaw.us/code/5c3d7227-d356-4c7c-9d08-ce4bc25c2455

SEC. 31-604. - LIGHTING.

(a) PURPOSE. These provisions are intended to control the use of outdoor artificial illuminating devices emitting rays into the night sky which have a detrimental effect on astronomical observations, and which create glare. It is the intention of this Ordinance to encourage good lighting practices such that lighting systems are designed to conserve energy and money, to minimize glare, to protect the use and enjoyment of surrounding property, and to increasing nighttime safety, utility, security and productivity. (b) APPLICABILITY. The provisions of this Section shall apply to any application for site plan or subdivision plat approval for a non-residential use. (c) SHIELDING AND FILTRATION. (1) All non-exempt outdoor lighting fixtures shall be limited to the types of fixtures specified in Table 604-1 of this Ordinance and shall have shielding and filtration as required by Table 604-1 of this Ordinance. (2) Light source locations shall be chosen to minimize the hazards of glare. The ratio of spacing to mounting height shall not exceed a 4:1 ratio. (3) Poles and standards. All poles or standards used to support outdoor lighting fixtures shall be anodized or otherwise coated to minimize glare from the light source. (d) ILLUMINATION. In order to minimize glare and hazardous conditions, illumination levels shall not exceed the levels set forth in Table 604-2 for any use permitted by this Ordinance. The maximum illumination shall be measured at grade at the property line of the site in accordance with Subsection (h) of this Section. (e) STREET LIGHTS. Street lights shall be installed by the Applicant for approval of any major subdivision, as defined by Article 5 of this Ordinance. The applicant shall design the proposed street lighting system in accordance with the criteria set forth in Subsections (1) and (2), below, and furnish payment equal to all applicable installation costs and first seven years' rental charge for such system. Funds necessary to pay these costs shall be deposited with the City prior to final plat approval. Said street lights shall comply with the following standards: (1) Street lights shall have a minimum size of 5,000 lumen, unless a larger size lamp is needed for highway safety purposes and/or road intersections, as determined by the Directorof Public Works. (2) Street light poles shall be designed so as to be placed in accordance with VDOT or City standards. Placement of the street light poles shall be on or near side property lines. (f) PARKING LOT LIGHTING REQUIREMENTS. Adequate lighting shall be provided for surface parking facilities used at night. (1) ILLUMINATION REQUIREMENTS. The minimum required lighting intensity to be provided in all parking areas is 1.0 footcandle; provided, however, that the lighting intensity at the property line for parking lots adjoining the public right-of-way or residential areas shall not exceed a maximum lighting intensity of 0.5 footcandles. (2) LIGHTING LOCATION. Parking area lighting shall be located in landscaped areas such as planting islands and buffers. (3) SUBMITTAL REQUIREMENTS. A lighting plan shall be submitted which details the location and specifications of all lighting provided. An ISO footcandle diagram shall also be provided to indicate the level and extent of proposed lighting. (g) EXEMPTIONS. (1) FOSSIL FUEL LIGHT. All outdoor light fixtures producing light directly by the combustion of natural gas or other fossil fuels are exempt from all requirements of this Ordinance. (2) STATE AND FEDERAL FACILITIES. Outdoor light fixtures installed on, in and in connection with those facilities and land owned or operated by the Federal Government or the Commonwealth of Virginia, or any department, division, agency or instrumentality thereof, are exempt from all requirements of this Ordinance. Voluntary compliance with the intent of this Ordinance at those facilities is encouraged. (h) MEASUREMENT. (1) METERING EQUIPMENT. Lighting levels are to be measured in footcandles with a direct-reading, portable light meter. The meter typically has a color and cosine-corrected sensor with multiple scales and shall read within an accuracy of plus or minus five percent (5%). It shall have been tested, calibrated, and certified by an independent commercial photometric laboratory or the manufacturer within one year of its use. (2) METHOD OF MEASUREMENT. The meter sensor shall be mounted not more than six (6) inches above ground level in a horizontal position. Readings are taken by qualified personnel only after the cell has been exposed long enough to provide a constant reading. Measurements are made after dark with the light sources in question on, then with the same sources off. The difference between the two readings shall be compared to the maximum permitted illumination and property line at ground level. This procedure eliminates the effects of moonlight and other ambient light sources. Where light patterns overlap, their total intensity shall be the sum of their individual intensities. [image omitted; see the official code] TABLE 604-1: SHIELDING REQUIREMENTS Fixture Lamp Type | Shielded | Filtered Low Pressure Sodium 1 | No | None High Pressure Sodium | Fully | None Metal Halide | Fully 2,6 | Yes Fluorescent | Fully 3,5 | Yes Quartz 4 | Fully | No Incandescent, Greater than 150W | Fully | None Incandescent, 150W or Less | None | None Fossil Fuel | None | None Glass Tubes filled with Neon, Argon, Krypton | None | None NOTES: 1 This is the preferred light source to minimize undesirable light emission into the night sky affecting astronomical observations. 2 Metal halide lighting used primarily for display purposes shall not be used for security lighting after 11:00 p.m. Metal halide lamps shall be installed only in enclosed luminaries. 3 Outdoor advertising signs of the type constructed of translucent materials and wholly illuminated from within do not require shielding. Dark backgrounds with light lettering or symbols are preferred, to minimize detrimental effects. Unless conforming to the above dark background preference, total lamp wattage per property shall be less than 41 Watts in Area A. 4 For the purposes of this Code, quartz lamps shall not be considered an incandescent light source. 5 Warm white and natural lamps are preferred to minimize detrimental effects. 6 Metal halide fixture lamp types shall be filtered. "Filtered" means any outdoor light fixture which has a glass, acrylic or translucent enclosure of the light source (quartz glass does not meet this requirement). TABLE 604-2: ILLUMINATION STANDARDS Area/Activity | Lux (LX) | Footcandles (FC) NON-RESIDENTIAL ZONING DISTRICTS Adjoining another Non-Residential Zoning District along Major Arterial | 20 | 2.0 Adjoining Residential Zoning District along Major Arterial | 10 | 1.0 Adjoining another Non-Residential Zoning District along Minor Arterial or Collector Street | 13 | 1.2 Adjoining Residential Zoning District along Minor Arterial or Collector Street | 6 | 0.6 Adjoining another Non-Residential Zoning District along Local Street | 10 | 0.9 Adjoining Residential Zoning District along Local Street | 4 | 0.4 Adjoining another Non-Residential Zoning District along Property Line | 10 | 0.9 Adjoining Residential Zoning District along Property Line | 2 | 0.2 OUTDOOR EVENTS Adjoining Non-Residential Zoning District | 1,000 | 100 Adjoining or within one-thousand (1,000) feet of Residential Zoning District | 100 | 10

(Ord. No. 18-O-131, § 2(Exh. B), 12-19-2018)

Ask a question about Suffolk law

Corpus searches the Suffolk sections it holds and shows the ones that match, with their citations. Free, no sign-in.