§ 2.02.090 — Amendment to IBC Section 105.2 – Work exempt from permit

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.02.090

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/7c86d445-d908-4dc7-8c90-232f737ef24c

§ 2.02.090: Amendment to IBC Section 105.2 – Work exempt from permit.

105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: 1. | One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11 m2). 2. | Fences not over 7 feet (1829 mm) high. 3. | Oil derricks. 4. | Retaining walls which are not over four feet (1219 mm) in height, measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or III-A liquids. A Fence supported by a retaining wall shall be considered a surcharge. 5. | Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons (18,925 L) and the ratio of height to diameter or width is not greater than 2:1. 6. | Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade and on grade concrete patios with a cumulative impact not exceeding 2,000 Sq. Ft. (185.81 sq-M), provided they are not over any basement or story below and are not part of an accessible route. 7. | Painting, papering, tiling, carpeting, cabinets, counter tops, and similar finish work. 8. | Temporary motion picture, television, and theater stage sets and scenery. 9. | Prefabricated swimming pools accessory to a Group R-3 occupancy, as applicable in Section 101.2, which are less than 24 inches (610 mm) deep, are not greater than 5,000 gallons (18,925 L), and are installed entirely above ground. 10. | Shade cloth structures constructed for nursery or agricultural purposes, not including service systems. 11. | Swings and other playground equipment accessory to detached one-and two-family dwellings. 12. | Window awnings in Group R-3 and U occupancies supported by an exterior wall which do not project more than 54 inches (1372mm) from the exterior wall and do not require additional support. 13. | Non-fixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1753 mm) in height. Electrical: See TMC Chapter 12.06A. Gas: 1. | Portable heating appliance. 2. | Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. Mechanical: 1. | Portable heating appliance. 2. | Portable ventilation equipment. 3. | Portable cooling unit. 4. | Steam, hot, or chilled water piping within any heating or cooling equipment regulated by this code. 5. | Replacement of any part which does not alter its approval or make it unsafe. 6. | Portable evaporative cooler. 7. | Self-contained refrigeration system containing 10 pounds (4.54 kg) or less of refrigerant and actuated by motors of 1 horsepower (746 W) or less. Plumbing: 1. | The stopping of leaks in drains, water, soil, waste, or vent pipe, provided, however, that if any concealed trap, drain pipe, water, soil, waste, or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. | The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes, or fixtures. 105.2.1 Emergency repairs. Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the next working business day to the Building Official. 105.2.2 Repairs. Application or notice to the Building Official is not required for ordinary repairs to structures, replacement of lamps, or the connection of approved portable electrical equipment to approved permanently installed receptacles. Such repairs shall not include the cutting away of any wall, partition, or portion thereof, the removal or cutting of any structural beam or load-bearing support, or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring, or mechanical or other work affecting public health or general safety. 105.2.3 Public service agencies. A building permit shall not be required for the installation, alteration, or repair of generation, transmission, distribution, or metering, or other related equipment that is under the ownership and control of public service agencies by established right. Other City permits shall still be required unless specifically exempted. 105.2.4 City of Tacoma Projects and Department of Transportation Projects. A building permit shall not be required for the construction of roads, highways, freeways, and other structures related to such construction, by or under contract to the City of Tacoma, or the Washington State Department of Transportation. Other City permits shall still be required unless specifically exempted. Exceptions: A. | Buildings and other structures not normally included in road or highway construction shall require building and other construction permits.

(Repealed and reenacted by Ord. 27890 Ex. A, 2010-06-15 ; repealed and reenacted by Ord. 28155 Ex. A, 2013-06-11 ; Ord. 28089 Ex. B, 2012-09-25 ; Ord. 28363 Ex. A, 2016-06-14 ; Ord. 28443 Ex. C, 2017-08-01 ; Ord. 28561 Ex. A, 2018-11-27 ; Ord. 28701 Ex. A, 2020-11-17 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.