§ 2.02.140: Amendment to IBC Section 504.4 – Number of Stories – by amending subsection 504.4.1 WA State amendment to the IBC and by addition of a new Section 504.4.1.1 – Type B occupancies within R-1 and R-2 occupancies.
The following section amends Section 504.4.1 of the State Building Code amendments to IBC Section 504.4 – Number of Stories, by replacing 504.4.1 in its entirety, and by addition of a new Section 5.4.4.1.1. 504.4.1 Stair Enclosure Pressurization Increase. For Groups R-1 and R-2 in buildings of Type VA or IIIA construction, or I-1 Condition 2 Assisted living facilities licensed per Chapter 388-78A WAC and residential treatment facilities as licensed by Washington state under chapter 246-337 WAC located in buildings of Type VA construction equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, the maximum number of stories permitted in Section 504.4 may be increased by one provided the interior exit stairways and ramps are pressurized in accordance with Sections 909.6.3 and 909.20. Legally required standby power shall be provided for buildings constructed in compliance with this section and be connected to stairway shaft pressurization equipment, elevators and lifts used for accessible means of egress, hoistway pressurization equipment (if provided) and other life safety equipment as determined by the authority having jurisdiction. For the purposes of this section, legally required standby power shall comply with most currently adopted NEC Section 701.12, options (A), (B), (C), (D), (E), (F), or (G) or subsequent revised section number(s). 504.4.1.1 Type B Occupancies within R-1 and R-2 occupancies. Provided the building meets the additional requirements in Section 504.4.1 as amended by the State Building Code, Type B occupancies that are considered accessory to and for the exclusive use of the R-1 and R-2 uses, including such uses as assembly areas, exercise rooms, or other amenity spaces with less than 50 occupants, may be permitted on all stories that the R-1 and R-2 uses are permitted. These spaces must also meet all the additional provisions as specified in the State Building Code amendment (WAC 51-50-0504) to IBC 504 – Building Height and Number of Stories.
(Repealed and reenacted by Ord. 27890 Ex. A, 2010-06-15 ; repealed and reenacted by Ord. 28155 Ex. A, 2013-06-11 ; repealed and reenacted by Ord. 28363 Ex. A, 2016-06-14 ; Ord. 28590 Ex. A, 2019-06-18 ; Ord. 28729 Ex. A, 2021-01-26 ; Ord. 28957 Ex. A, 2024-03-05 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.