§ 2.02.160: Amendment to IBC Section 1502 – Roof Drainage.

Section 1502 in the currently adopted edition of the IBC shall be replaced in its entirety with the following: 1502.1 General. Design and installation of roof drainage systems shall comply with Section 1502 of this code and the UPC as applicable. 1502.2 Overflow Drains. Where roof drains are required, overflow drains having the same size as the roof drains shall be installed with the inlet flow line located two inches above the low point of the roof. 1502.3 Scuppers. Where scuppers are used for secondary (emergency overflow) roof drainage, the quantity, size, location, and inlet elevation of the scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by Section 1611.1. Scuppers shall be three times the size of roof drains and have an opening dimension of not less than four inches (102 mm). The flow through the primary system shall not be considered when locating and sizing scuppers. Scuppers may be installed in adjacent parapet walls with the inlet flow line located not more than two inches above the lowest point for the roof area served by the scupper. 1502.4 Gutters. Gutters and leaders placed on the outside of buildings other than Group R-3, private garages, and buildings of type V construction shall be of noncombustible material or a minimum of Schedule 40 plastic pipe. 1502.5 Roof Slope. Roofs shall be sloped a minimum of 1 unit vertical in 48 units horizontal (2% slope) for drainage unless designed for water accumulation in accordance with Chapter 16, and approved by the Building Official. Vegetated roofs may be approved as an alternate design. 1502.6 Roof Drains. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Vegetated roofs may be designed with alternate drainage systems as approved by the Building Official. Roof drains shall be sized and discharged in accordance with the Uniform Plumbing Code. Roof drainage shall be directed away from the building and discharged to the storm sewer or to other approved disposal systems. Roof drainage shall not be connected to, or allowed to infiltrate into, the footing drain system. Overflow drains shall discharge to an approved location and shall discharge at a point above the ground, which can be readily observed. Overflow drains shall not be connected to roof drain lines. 1502.7 Concealed Piping. Roof drains and overflow drains, where concealed within the construction of the building, shall be installed in accordance with the Uniform Plumbing Code. 1502.8 Over Public Property. Roof drainage water from a building shall not be permitted to flow over public property unless part of a City approved dispersion system and where an easement has been obtained.

(Repealed and reenacted by Ord. 27890 Ex. A, 2010-06-15 ; repealed and reenacted by Ord. 28155 Ex. A, 2013-06-11 ; Ord. 28327 Ex. A, 2015-11-03 ; Ord. 28363 Ex. A, 2016-06-14 ; Ord. 28729 Ex. A, 2021-01-26 ; Ord. 28957 Ex. A, 2024-03-05 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.