§ 5.50.140: Overflow gutters.
A. Overflow gutters shall be required on all pools having a surface area of over 2,500 square feet. (Pools having a surface area of less than 2,500 square feet shall be provided either with overflow gutters or skimming devices.) B. Overflow gutters shall extend completely around the pool, except at steps or recessed ladders in the shallow portion. The overflow gutter shall also serve as a handhold. This gutter shall be capable of continuously removing 100 percent of the recirculation pump capacity plus one-fifth of the balancing tank capacity expressed in gallons per minute. All overflow gutters shall be connected to the recirculation system through a properly designed surge tank. The gutter, drains, and return piping to the surge tank shall be designed to rapidly remove overflow water caused by recirculation displacement, wave action, or other causes produced from the maximum pool bathing load. Gutters (roll out) shall be adequately sloped to provide rapid drainage to drains not more than 15 feet apart, and such drainage shall be returned to the filters. The opening into the gutter beneath the coping shall not be less than four inches, and the interior of the gutter shall not be less than three inches wide, with a depth of at least three inches and designed to be easily cleanable. Where large gutters are used, they shall be designed to prevent entrance or entrapment of bathers’ arms or legs. The overflow edge or lip shall be rounded and not thicker than 2-1/2 inches for the top two inches. The outlet fittings shall have a clear opening in the grating at least equal to 1-1/2 times the cross-sectional area of the outlet pipe. C. Balancing tanks shall be required where overflow gutters or channels are used. The capacity in gallons shall be equal to the maximum bathing load expressed. If the balancing tank is designed to serve as a makeup water tank or to prevent air lock in the pump Section line, or both, the capacity shall be increased sufficiently to accommodate these uses. Filter pits for vacuum type filters may serve as balancing tanks if properly designed to accommodate this additional volume. D. Nothing in this Section shall preclude the use of roll-out or deck-level type pools. Such designs shall conform to the general provisions relating to overflow rates. The design of the curbs and handholds shall conform to accepted standards, and the approval of the Health Officer shall be based on detailed review of this feature of construction and evaluated in the light of proposed use of pool.
( Ord. 24602 § 1, 1990-04-03 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.