For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.50.280 — Disinfection and quality of water

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 5.50.280

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/9eca3ccc-adf3-45fd-b00f-fd8050f96c75

§ 5.50.280: Disinfection and quality of water.

A. A disinfection process or procedure shall be used at all pools subject to this chapter for the purpose of insuring continuous disinfection of the water throughout the pool during the period the pool is in use. When chlorine or chlorine compounds are used as the disinfectant, the water in the pool at all times while in use shall contain a free chlorine residual of not less than 1.0 parts per million as measured by the DPD method, or shall contain a free chlorine residual of a higher value to be determined by the Health Officer. If other halogens are used, residuals of equivalent disinfecting strength shall be maintained. A testing kit for measuring the concentration of disinfectant, accurate within 0.1 ppm, shall be provided at each pool. B. When cyanuric acid compounds are used as a disinfectant, or where cyanuric acid is added, the cyanurate concentration shall not exceed 90 parts per million, and the free chlorine residual shall be at least 1.5 parts per million. Where water quality and clarity is in question, the Health Officer may decrease the maximum allowed cyanurate concentration. A test kit to monitor cyanuric acid shall be kept and used at each facility where cyanuric acid compounds are used. C. The Health Officer may accept other disinfecting materials or methods when they have been adequately demonstrated to provide a satisfactory residual effect and to otherwise be equally as effective under conditions of use as the chlorine concentration required herein, and shall not be dangerous to public health, create objectionable physiological effects, or impart toxic properties to the water. D. The swimming pool water shall be maintained in an alkaline condition as indicated by a pH of between 7.2 and 8.0, or as otherwise allowed by the Health Officer. When chlorine is used as the disinfectant, and when the pH is maintained between 7.6 and 8.0, the minimum free chlorine residual shall be no less than 2.0 ppm. A pH testing kit accurate to the nearest 0.2 pH unit shall be provided at each swimming pool. The total alkalinity of the water in pools shall be at least 80 ppm. Suitable equipment for the feeding of pH regulating chemicals at such points that their use will be most effective shall be provided in public pools. E. The water shall have sufficient clarity at all times so that the main drain is clearly visible from the farthest end of the pool or the appropriate life guarding station if provided. Failure to meet this requirement shall constitute grounds for immediate closure of the pool. F. Pool water shall be maintained free of eye-and skin-irritating substances. G. Not more than 15 percent of the samples covering any considerable period of time, no more than two consecutive samples, shall either (1) contain more than 200 bacteria per milliliter, as determined by the standard (35,C) agar plate count, or (2) show positive test (confirmed test) for coliform organisms in any of the five 10-milliliter portions of a sample or more than 1.0 coliform organisms per 50 ml when the membrane filter test is used. All samples shall be collected, dechlorinated, and examined in accordance with the procedures outlined in the latest edition of Standard Methods for the Examination of Water Waste-Water (APWA). The Health Officer shall prescribe the type and frequency of collection and examination of samples to assure water quality meets minimum requirements. H. The presence of Pseudomonas aeruginosa or other pathogenic organisms in the pool water shall be justification for closure of any pool until subsequent sampling shows the water to be free of such organisms. I. An adequate test kit shall be kept and maintained on the premises which can measure the following chemical parameters: 1. Free chlorine residual by the DPD method. 2. Total chlorine residual by the DPD method. 3. pH as in Section 5.50.280D. 4. Total alkalinity. 5. Cyanuric acid, if such compounds are used in the water. 6. Where disinfectants other than chlorine are used and approved by the Health Officer, the test kit requirements shall be determined by the Health Officer. J. The chemical parameters listed in subsection I of this Section shall be measured and recorded with an adequate frequency as determined by the Health Officer.

( Ord. 24602 § 1, 1990-04-03 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.