§ 5.50.160: Recirculation system.

A. A recirculation system, consisting of pumps, piping, filters, water conditioning, and disinfection equipment and other accessory equipment shall be provided at all pools, except spray pools, which will clarify and disinfect the pool volume of water in six hours or less in a public pool and 12 hours or less in a semipublic pool. However, for semipublic pools, it is recommended that the pool volume of water be recirculated in eight hours or less. Not less than 60 percent of the recirculated water shall be returned through the overflow channels or skimming devices. B. All piping shall be designed to reduce friction losses to a minimum and to carry the required quantity of water at a maximum velocity not to exceed eight feet per second. C. On systems where the pump is located before the filter, the recirculation system shall include a strainer to prevent hair, lint, etc., from reaching the pump and filters. Strainers shall be corrosion-resistant with openings which will provide a free flow area at least four times the area of pump suction line and shall be readily accessible for frequent cleaning. D. A vacuum-cleaning system shall be provided. When the vacuum-cleaning system is an integral part of the recirculation system, sufficient connections shall be located in the walls of the pool, at least eight inches below the water line, or may be a component part of the skimmer. E. A rate-of-flow indicator, reading in gallons per minute, shall be installed and located on the pool return (inlet) line. The indicator shall be capable of flows measuring at least 1-1/2 times the design flow rate, shall be accurate within 10 percent of true flow, and shall be easy to read. F. Pumps shall be of adequate capacity to provide the required number of turnovers of pool water as specified in Section 5.50.170A, and whenever possible shall be so located as to eliminate need for priming. If the pump or suction piping is located above the overflow level of the pool, the pump shall be self-priming. The pump or pumps shall be capable of providing flow adequate for the backwashing of filters. G. All electrical components of the recirculation system shall be approved by the electrical inspection authority having jurisdiction.

( Ord. 24602 § 1, 1990-04-03 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.