§ 5.50.220 — Disinfectant and chemical feeders
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 5.50.220
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/4e08e245-7d4f-43ac-9121-903f732cb474
§ 5.50.220: Disinfectant and chemical feeders.
A. Public and semipublic pools shall be equipped with a chlorinator, hypochlorinator, or other disinfectant feeder or feeders which: 1. Shall meet the requirements of the National Sanitation Foundation or equivalent. 2. Shall be of sturdy construction and materials which will withstand wear, corrosion, or attack by disinfectant solutions or vapors, and which are not adversely affected by repeated adjustments or other conditions anticipated in the use of the device. The feeder shall be capable of being easily disassembled for cleaning and maintenance. The design and construction shall be such as to preclude stoppage from chemicals intended to be used or foreign materials that may be contained therein. The feeder shall incorporate failure-proof features so that the disinfectant cannot feed directly into the pool, pool piping, water supply system, or pool enclosure under any type of failure of the equipment or its maintenance. 3. When chlorinators are used for public pools, the capacity shall be sufficient to feed at the rate of at least three pounds of chlorine per 24 hours per 10,000 gallons of pool capacity; and for semipublic pools the capacity shall be sufficient to feed at the rate of at least one pound of chlorine per 24 hours per 10,000 gallons of pool capacity. 4. Shall have a graduated and clearly marked dosage adjustment to provide flows from full capacity to 25 percent of such capacity. The device shall be capable of continuous delivery within 10 percent of the dosage at any setting. 5. When the disinfectant is introduced at the suction side of the pump, a device or method shall be provided to prevent air lock of the pump or recirculation system. 6. When compressed chlorine gas is used, the following additional features shall be provided: a. The chlorine and chlorinating equipment shall be in a separate, well-ventilated room. Such room shall not be below ground level and shall be provided with vents near the floor which terminate out of doors. The door of the room shall not open to the pool, but shall open to the outside and in a direction away from prevailing winds or ventilation systems. b. The chlorinator equipment shall be of rugged design, capable of withstanding wear without developing leaks. c. Chlorine cylinders shall be anchored in a manner to prevent their falling over. A valve stem wrench shall be maintained on any chlorine cylinders in use so the chlorine can be shut off quickly in the case of an emergency. Valve protection hoods shall be kept in a separate place except when the cylinders are connected to the chlorinator system. Weight scales or some other means of measuring the amount of chlorine remaining in the cylinders shall be provided. d. The chlorine feeding device shall be designed so that during accidents or interruptions of the water supply, leaking chlorine gas will be conducted to the out-of-doors. e. Chlorinator shall be a solution feed type, capable of delivering chlorine at its maximum rate without releasing chlorine gas to the atmosphere. f. The chlorinators shall be designed to prevent the backflow of water into the chlorine solution container. g. Chlorine leak detector, such as bottled ammonia, shall be provided in the chlorinator room. h. An emergency plan for a chlorine gas leak, in accordance with Chapter 4, Section 3 of the National Fire Protection Handbook and the Uniform Fire Code (1982 ed., Article 75), and approved by the Tacoma Fire Department, shall be posted outside the chlorine cylinder room. Designated personnel shall be trained in the implementation of such a plan. 7. When a hypochlorite solution is used, it shall be fed through hypochlorination equipment. Such equipment shall also provide the following additional features: a. Feed shall be positive under all conditions of pressure in the circulating system. b. Dosage adjustment shall be provided to insure constant feed with varying supply or back pressure. c. Positive features to prevent backflow from recirculation system to the solution container, and provision for reducing to a minimum the entry into pool of calcium released from calcium hypochlorite. d. Provision to prevent siphoning of hypochlorite solution when the recirculation pump and hypochlorinator are both turned off. (This applies to above-pool-level installations only.) B. Equipment and piping used to apply chemicals to the water shall be of such size, design, and material that they may be cleaned and will be free from clogging, preferably of the positive displacement type. All material used for such equipment and piping shall be resistant to the action of chemicals to be used therein. C. Methods other than use of a positive displacement-type pump of disinfectants will be allowed in semipublic pools if capable of maintaining the minimum required chlorine content at all times the pool is in use. Hand feeding may be used in public pools on an emergency basis only.
( Ord. 24602 § 1, 1990-04-03 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.