§ 9.12 — Existing Buildings

Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Code of General Ordinances § 9.12

Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/6de91a94-55a3-4736-bdb6-f7b4671605fd

9.12. - Existing Buildings.

A. Scope. The legal Occupancy of any Building existing on the date of adoption of this Code shall be permitted to continue without change, except as provided in this Code. B. Alterations. 1. Conformance With Code. Alterations to an existing Building shall conform with this Code. 2. Exception. Alterations to existing one- and two-family Dwellings shall conform with this Code, subject to the following standards. a. Existing stairways in good repair and not being Altered or replaced may remain in use if the stairway meets the following criteria: (1) Riser height does not exceed eight and one-fourth (8-1/4) inches. (2) Tread depth is not less than eight and one-half (8-1/2") inches. (3) Head room is a minimum of seventy-two (72) inches. (4) Stairway width is at least thirty-four (34) inches. (5) Intermediate baluster spacing is no more than six (6) inches. b. Existing areas with no framing or restructuring involved maintain a ceiling height of eighty (80) inches. c. Where ceiling finishes are not removed, installation of battery-operated smoke detectors is acceptable. d. Where wall or ceiling finishes are not removed, the existing insulation level may remain. e. Where no wall finishes are removed, the existing receptacle outlet spacing may remain, provided there are at least two (2) separate and remote receptacles located in the room. f. In the absence of wall or ceiling-type light fixtures, one (1) of the two (2) required receptacle outlets shall be controlled by a remote switch. The application of the aforementioned standards may be appealed in writing to the Code Official authorized to grant modifications for good cause. C. Additions. Additions to an existing Building shall conform with this Code. D. Conformance of Alterations and Additions. If an Alteration or Addition exceeds fifty (50) percent of the gross area of the existing Building, the entire Building shall be made to conform with this Code. E. Change of Occupancy Classification. When a change in Occupancy classification of an existing Building occurs, all provisions of this Code shall be met prior to approval of Occupancy.

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.