9.20. - Electrical.

A. Qualifications. No Person, except as provided in Subsections B., C., and D. herein, shall install electrical wiring and equipment within the City, or apply for a Permit for which the performance by a licensed contractor is applicable, without first obtaining certifications as required by Wis. Stats. § 101.862, and conforming with all applicable State laws, rules and regulations. B. Owner Occupied Residential Property. Property owners may install electrical wiring and equipment within the City for single family Dwellings which they occupy, upon obtaining a Permit from the Department to do so. The Permit shall be issued only after passing an exam administered by the Department to demonstrate that he/she is competent to perform the Work in conformity with applicable State and City laws, rules and regulations. Owners/occupants of single family Dwellings who pass the exam are prohibited from performing electrical wiring or Alteration of service entrance equipment and panels. C. City Employees. City employees may install electrical wiring and equipment for the City upon being trained to perform the Work in conformance with State and City laws, rules and regulations. D. Low Voltage Wiring. Any Person shall be exempt from this licensing requirement if the sole scope of the electrical Work to be performed is limited to low voltage wiring. Low voltage wiring performed on one- and two-family Dwellings is exempt from the Permit requirement. E. Energizing New or Temporary Electrical Service. It shall be unlawful for a utility furnishing electric power within the City to energize a new or temporary service prior to an inspection of the Premises to be served being made by the Code Official, and prior to the Code Official approving the installation and notifying the utility. F. City Mandated De-Energization of Electrical Service. The Code Official, upon discovering an energized electrical service which constitutes a potential hazard to Person or property, may, in writing, direct a utility furnishing such electrical service to de-energize the electrical service. It shall be unlawful for a utility to fail to promptly comply with the written directive within a reasonable time, except where to do so would de-energize the electrical service of a non-offending third party sharing the same service connection. A copy of the written directive shall be furnished forthwith to the owner/occupier of the Premises to be de-energized, whenever possible. G. Residential Electrical Wiring. Any Alteration to any portion of residential electrical service equipment shall conform to the following provisions: 1. The electric service shall be a minimum of one hundred (100) amperes for a single-family Dwelling, and one hundred fifty (150) amperes for a two-family Dwelling. Service conductors and all associated equipment shall be new. All Work shall be installed pursuant to the National Electrical Code, SPS 316 of the Wisconsin Administrative Code, and the current WE Energies Service and Metering Manual. 2. All Dwelling Units shall be metered separately. 3. All banded meter sockets shall be replaced. 4. Property shall be supplied by only one (1) riser and service. 5. Service shall be located a minimum of three (3) feet horizontally from gas service. 6. Where electrical Work is done in a basement or attic, knob and tube wiring, if present, shall be removed and replaced with wiring in conformance with this Code. 7. Illumination shall be provided at all stairways and exits. Stairways going to a habitable room shall be provided with a three-way switch. 8. Convenience outlets shall be located as needed to prevent the use of extension cords. 9. When receptacles are being replaced in basements, crawl spaces, kitchens and bathrooms they shall be GFCI protected. 10. In Accessory Buildings with electrical wiring a ground receptacle shall be provided and shall be ground fault protected when replaced in existing outlet. 11. The Permit shall be conditioned upon all safety violations being corrected.

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.