Sec. 18-223. - Foundation walls.

(a) Generally. (1) Foundation walls shall be continuous under habitable areas of principal buildings. Overhanging bays and projecting floors are permitted provided that such cantilevered floors are adequately supported to sustain such loads as they may carry. (2) The top of foundation walls of any building or structure of wood frame construction shall be at least four inches above lot grade at all exterior walls, and no exterior wood construction shall be exposed less than three inches above grade. Where the elevation of the lot grade adjoining the exterior walls of such building or structure varies and the four-inch requirement above such grade cannot be maintained, the joist skirt shall be protected with waterproof building paper or flashing. (3) In no case shall joists be lower than the grade. All footings shall set at least 24 hours before the foundation wall or wall forms shall be built. (b) Thickness. (1) Foundation walls for one- and two-story frame buildings which are constructed of brick and solid or hollow concrete masonry units shall be of the following thicknesses: TABLE B Foundation wall construction | Maximum height unbalanced fill in feet* | Frame | Minimum thickness (inches) masonry or masonry veneer Masonry | 3 | 10 | 10 5 | 10 | 12 7½ | 10 | 12 Plain concrete | 3 | 8 | 8 5 | 8 | 10 7½ | 8 | 10 *When foundation wall is balanced with fill on both sides, foundation wall thickness may be reduced by two inches but shall not be less than eight inches in thickness. All masonry foundation walls shall be capped with solid masonry units. (2) Foundation walls of poured monolithic concrete shall be eight inches thick whether reinforced or not. If the superstructure is to be of solid brick or masonry construction, the foundation wall shall be ten inches thick. (c) Pilasters. (1) When a girder whose span exceeds 12 feet frames into a masonry wall, pilasters of a minimum size of four inches by 12 inches built integrally with the wall shall be provided. (2) Pilasters shall be required where the unsupported length of any foundation wall exceeds 30 T, where "T" is the thickness of the foundation wall. Such pilasters shall be not less than 16 inches wide and at least 1⅓ times the thickness of the wall of which it is a part. Exception: Pilasters shall not be required in poured monolithic plain or reinforced concrete foundation walls of buildings. (d) Girder bearing. Four inches of end bearing shall be provided for girders framing into foundation walls, and when wood girders are used an air space shall be provided between the foundation walls and the ends and sides of the girder. (e) Dampproofing. Masonry foundation walls of basements and crawl spaces shall be made dampproof by the application to the exterior surfaces thereof of a continuous coat of three-eighths-inch-thick waterproof cement mortar or Portland cement mortar plus a coat of bituminous dampproofing material over the parging from top of stone to final grade. One coat of bituminous dampproofing material shall be applied to concrete foundation walls from top of stone to finish grade. (f) Storage and materials. Cement and aggregates shall be stored in such a manner as to prevent deterioration or the intrusion of foreign matter. Any material which has deteriorated or which has been damaged shall be removed completely from the premises.

(Code 1973, §§ 30.19.010—30.19.060)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.