§ 18-224 — Basements, cellars, basementless spaces

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-224

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/52e5343f-b3e4-474a-934a-3476ad0e23ec

Sec. 18-224. - Basements, cellars, basementless spaces.

(a) Basement floor. All basements and cellars shall be provided with a minimum of three-inch concrete floor placed on a minimum of three inches of three-quarter-inch crushed road gravel. An inspection shall be called for and made prior to laying concrete to construct the basement floor. (b) Basementless spaces. Basementless spaces may be used or constructed according to the following specifications: (1) The ground level shall be at least two feet below any part of the wood construction. (2) In such spaces, all debris, sod, tree stumps, and other organic materials shall be removed and a smooth surface free of pockets shall be provided. A minimum two-inch-thick concrete slab shall be installed. (3) Where the floor level within the foundation walls is below the outside grade, drain tile shall be provided around the exterior of the walls and connected to the house tile. Special consideration shall be given by the chief building inspector if water conditions exist that would require interior drain tile. (4) Foundation wall vents shall be provided, located near the corner of such space. Such vents shall have an aggregate free ventilating area equal to two square feet per 100 lineal feet of wall enclosing such space, or a minimum aggregate area of two square feet. All basementless spaces shall be provided with a minimum access opening of four square feet. If an access opening is in the basement wall and is kept clear and open except for screening which allows for air movement, this opening may be substituted for the above required ventilation area. (c) Slab construction. The entire area shall consist of a base of three inches in thickness of gravel or other approved material well tamped in place, over which there shall be placed a vapor barrier covered with a layer consisting of four inches in thickness of concrete.

(Code 1973, §§ 30.21.010—30.21.030)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.