34.35 - Additions to Buildings or Remodeling.
Where kitchens and bathrooms are reconfigured, the wiring shall conform to the 2023 National Electrical Code and the provisions of this Code. Where any habitable room has the wall covering removed, exposing the structure, the wiring shall conform to the 2023 National Electrical Code and the provisions of this Code. The minimum size of electrical service(s), over-current panel(s) for the electrical system of an existing dwelling(s) which is being remodeled or added to shall be computed and installed according to Sections 34.32, and 34.34 of this Code, the same as for new dwellings. Existing equipment which meets the computed minimum requirements shall be approved by the inspector. Where the construction, alteration or modification of a building reduces the clearance of the service drop conductors below the acceptable minimum clearance required by Article 230.24, as amended, of the 2023 National Electrical Code, such service conductors shall be relocated according to the directions of the electric utility company. (040-25)