Sec. 5-9-517. - Special nonresidential building provisions.

The provisions of this section shall apply to nonresidential units and structures. A. Swinging exterior glass doors, wood or metal doors with glass panels, solid wood or metal doors shall be constructed or protected as follows: 1. Wood doors shall be of solid core construction with a minimum thickness of 1¾ inches. Wood panel doors with panels less than one-inch thick shall be covered on the inside with a minimum 16 U.S. gauge sheet steel or its equivalent, which is to be attached with screws on minimum six-inch centers. Hollow steel doors shall be of a minimum 16 U.S. gauge and have sufficient reinforcement to maintain the designated thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device. 2. Except when double cylinder deadbolts are utilized, any glazing utilized within 40 inches of any door locking mechanism shall be constructed or protected as follows: a. Fully tempered glass or rated burglary resistant glazing; or b. Iron or steel grills of at least 1/8-inch material with a minimum two- inch mesh secured on the inside of the glazing may be utilized; or c. The glazing shall be covered with iron bars of at least ½-inch round or one-inch by ¼-inch flat steel material, spaced not more than five inches apart, secured on the inside of the glazing. d. Items b and c above, shall not interfere with the operation of opening windows if such windows are required to be openable by the California Building Code. 3. Doors without mechanical locks may be secured with a magnetic locking device which shall have a minimum holding force of 1,600 lbs. and a minimum 12-hour backup battery source. B. All swinging exterior wood and steel doors shall be equipped as follows: 1. A single or double door shall be equipped with a double or single cylinder deadbolt. The bolt shall have a minimum projection of one inch and be constructed so as to repel a cutting tool attack. The deadbolt shall have an embedment of at least ¾ inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five-pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least ¼ inch in diameter. The provisions of the preceding paragraph do not apply where: (1) panic hardware is required, or (2) an equivalent device is approved by the Enforcing Authority. 2. Double doors shall be equipped as follows: a. The inactive leaf of double door(s) shall be equipped with metal flush bolts having a minimum embedment of ⅝ inch into the head and threshold of the doorframe. b. Double doors shall have an astragal constructed of steel a minimum of 0.125-inch thick, which will cover the opening between the doors. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with nonremovable bolts spaced apart on not more than 10-inch centers. (The door to which such an astragal is attached must be determined by the fire safety codes adopted by the Enforcing Authority.) C. Aluminum frame swinging doors shall be equipped as follows: 1. The jamb on all aluminum frame swinging doors shall be so constructed or protected to withstand 1,600 pounds of pressure in both a vertical distance of 3 inches and a horizontal distance of one inch each side of the strike, so as to prevent violation of the strike. 2. A single or double door shall be equipped with a double cylinder deadbolt with a bolt projection exceeding one inch or a hook-shaped or expanding deadbolt that engages the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of five-pin tumblers and a cylinder guard. D. Panic hardware, whenever required by the California Building Code or Title 24, California Code of Regulations, shall be installed as follows: 1. Panic hardware shall contain a minimum of two locking points on each door; or 2. On single doors, panic hardware may have one locking point, which is not to be located at either the top or bottom rails of the doorframe. The door shall have an astragal constructed of steel 0.125-inch thick, which shall be attached with nonremovable bolts to the outside of the door. The astragal shall extend a minimum of 6 inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. 3. Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point, which will close the opening between them, but not interfere with the operation of either door. E. Horizontal sliding doors shall be equipped with a metal guide track at top and bottom, and a cylinder lock and/or padlock with a hardened steel shackle which locks at both heel and toe, and a minimum five-pin tumbler operation with nonremovable key when in an unlocked position. The bottom track shall be so designed that the door cannot be lifted from the track when the door is in a locked position. F. In office buildings (multiple occupancy), all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors. G. Glazing shall be deemed accessible, if any portion of it is within 40 inches of any door locking mechanism, and shall be constructed of either two part laminated glazing with a 0.06-inch inner layer or burglary resistant glazing. Exception: Glass doors at least ½ inch thick and greater than 2,880 square inches. H. Roof openings shall be protected as follows if the roof is accessible via an exterior ladder or the roof is less than 20 feet from ground level or if any portion of it is within 12 feet vertically or six feet horizontally from any exterior accessible surface or any adjoining roof, balcony, landing, stair tread or similar structure: 1. All skylights on the roof of any building used for business purposes shall be provided with: a. Rated burglary-resistant glazing; or b. Iron bars of at least one-half inch round or one by ¼-inch flat steel material, spaced not more than five inches apart, under the skylight and securely fastened; or c. A steel grill of at least ⅛-inch material with a maximum two-inch mesh under the skylight and securely fastened. 2. All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows: a. If the hatchway is of wooden material, it shall be covered on the inside with at least 16 U.S. gauge sheet metal, or its equivalent, attached with screws. b. The hatchway shall be secured from the inside with a slide bar or slide bolts. c. Outside hinges on all hatchway openings shall be provided with nonremovable pins when using pin-type hinges. I. Exterior mounted ladders are prohibited except: 1. Ladders with a minimum ⅛-inch thick steel plate, securely attached to the ladder edge on each side and extending to within two inches of the wall for a height of 10 feet above ground level. A door or cover shall be securely attached to the front of the ladder and be constructed of a minimum ⅛-inch steel, extending from ground level to at least 10 feet high. The ladder door shall have nonremovable hinge pins and be locked tight against the side wall by a locking mechanism with a minimum five pin tumbler operation, and attached with nonremovable bolts from the exterior; or 2. Ladders beginning a height of 10 feet above ground. J. There shall be no exterior phone panels. K. Buildings, open parking lots, walkways, and accesses thereto shall conform to the following light standards: 1. All types of exterior doors shall be illuminated, with an exterior light fixture, during the hours of darkness, with a minimum maintained one foot-candle of light, measured within a five-foot radius on each side of the door at ground level. 2. Recessed areas of buildings or fences, which have a minimum depth of two feet, a minimum height of five feet, and do not exceed six feet in width and are capable of human concealment, shall be illuminated with a minimum maintained 0.25 foot-candle of light at ground level during the hours of darkness. This requirement applies to defined recessed areas which are within six feet of the edge of a designated walking surface with an unobstructed pathway to it, not hindered by walls or hedge row landscaping a minimum of two feet in height. 3. Stairways shall be illuminated with a minimum maintained two foot-candles of light on all landings and stair treads, during the hours of operation, including one hour thereafter. 4. All interior or exterior corridors, passageways and walkways in any hotel, motel or inn shall be illuminated at all times with a minimum maintained one foot-candle of light on the walking surface. 5. All exterior pedestrian walkways, interior common corridors, and open parking lots shall be illuminated with a minimum maintained one foot-candle of light on the walking, parking or driving surface during the hours of operation and one hour thereafter. 6. The light source utilized to comply with this section shall have a rated average bulb life of not less than 20,000 hours, not battery operated, and controlled by a photocell device or a time clock with an astronomic clock feature. 7. Light fixtures for open parking lots may utilize motion sensing devices to raise and lower the light levels based upon the presence of vehicles or people. The light level shall not be less than a minimum maintained 0.25 foot-candle of light at ground level when not occupied. The motion sensing device shall only be used after business hours and shall be adjusted to sense and activate a light when a vehicle or person is within 24 feet of the fixture. Areas within a 50-foot radius of an elevator lobby/doors and stairways shall not fall below the required minimum maintained 1.0 footcandle of light. 8. Accessible luminaires utilized to meet the requirements of this section shall have fully enclosed vandal resistant light fixtures and be not less than three feet in height from ground level when used to illuminate walkways and a minimum of eight feet in height from ground level when illuminating surfaces associated with vehicles. Light fixtures shall be deemed accessible if mounted within fifteen feet vertically or six feet horizontally from any accessible surface or any adjoining roof, balcony, landing, stair tread, platform or similar structure. 9. A site plan shall be provided, and approved by the City, showing buildings, parking area, walkways, detailed landscaping with tree legend (if pole lights are used) and shrub legend (if bollards are used), fixture schedule, mounting height, lighting ratio and a point-by-point photometric calculation of the required light levels. If a parking lot is equipped with an occupancy sensor, then a point-by-point photometric calculation is required to show it meets the required minimum level of light. Foot-candles shall be measured at grade on a horizontal plane and conform to a uniformity ratio of six to one (6:1) average/minimum. Landscaping shall not be planted so as to obscure required light levels with light fixtures exceeding eight feet in height installed at least two feet from a tree's canopy at 70 percent maturity. 10. Private streets, drive aisles, alleys, and Fire Department required roadways designed for use only in emergency situations shall be illuminated using the same standards as established for public thoroughfares. L. Addressing for nonresidential buildings shall conform to the following specifications: 1. Numerals shall be mounted on the wall or window, not less than eight feet or higher than 30 feet from ground level and face the street on which the building is addressed. If the building does not have vehicle access from the addressed street, then the addressed street name must also be displayed. Numerals are to be clearly visible from this same street and not obscured by building landscaping at full maturity. Addressing shall be of a color contrasting to the background to which they are affixed. Method of attachment shall not include the use of two-sided tape or any material not resistant to weather conditions. 2. Where distance or intervening obstructions impair visibility from the street, addressing shall be mounted on all buildings so as to be visible from drive aisles and walkways internal to the site, and each such address, or an encompassing range of addresses, shall be displayed on monument signs visible from each site entrance from all approaching directions. In such cases, these signs shall be designed per No. 5 below. 3. Numerals shall be no less than six inches in height, if located less than 100 feet from the center line of the addressed street or 12 inches in height if placed further than 100 feet from the center line of the addressed street. The numerals shall be in a Sans Serif font with a stroke weight of medium to bold, or an approved equivalent font which is clearly legible, and illuminated during the hours of darkness, with a minimum of two footcandles of light on the numbers, using a light source provided with an uninterruptible A.C. power source or controlled only by a photoelectric device, which may be the common area site lighting. 4. The rear swinging doors of all buildings shall have address numbers or unit designation not less than six inches in height, using a Sans Serif font with a stroke weight of medium to bold, or an approved equivalent font which is clearly legible, and be of a color contrasting to the background to which they are affixed. Method of attachment shall not include the use of two-sided tape or any material not resistant to weather conditions. Exceptions: 1. Single tenant buildings with a single street address and rear building frontage of 300 feet or less, at least one rear door, nearest to the center, is required to have an address sign. 2. Single tenant buildings with a rear building frontage greater than 300 feet, but less than 600 feet, at least two rear doors are required to have address signs, located at the first door at each end of the building. 3. Single tenant buildings with a rear building frontage greater than 600 feet, at least three rear doors are required to have an address sign, located at the first door at each end of the building and at a middle door. 5. For sites having multiple buildings for which addressing mounted on the building is not clearly visible from the street, or for which drive aisles diverge from a site entrance in a manner such that the direct route to each building is not obvious, vehicle directional signs shall be provided. Vehicle direction signage from the point of site entry to each building entrance shall display building addresses or unit number range, and be located at all turning points along the route to a building entrance. Bottom of the address numbers on the sign copy shall be no less than two feet from ground level and not obstructed by landscaping or by parked cars. Numerals shall be at least four inches in height using a Sans Serif font with a stroke weight of medium to bold, or an approved equivalent font which is clearly legible. 6. Buildings with a total square footage of at least 10,000 square feet shall have rooftop numbers placed parallel to the addressed street, screened from public view and only visible from the air. The numerals are to be white, block lettered, constructed of weather resistant material, and placed against a black background. Address numbers are to be a minimum of four feet in height and 18 inches wide. When more than one street address is assigned to a building, the beginning and ending address numbers are to be placed on the rooftop at opposite ends of the building, reflecting the approximate location of these addresses. Exceptions: 1. For buildings having white roofing, black lettering shall be used in lieu of white lettering. 2. Buildings providing addressing for a helipad as specified in the California Building Code. 7. For sites having more than three separately addressed buildings with a common area sidewalk connecting each building, and the primary building entrances are not visible from the street or parking lot, pedestrian directional signage shall be provided. Signs shall be posted at all decision-making points, including walkway entrances and intersections. Bottom of the address numbers on the sign copy shall be no less than two feet from ground level and not obstructed by landscaping. Numerals, letters and arrows shall be at least three inches in height using a Sans Serif font with a stroke weight of medium to bold, or an approved equivalent font which is clearly legible. 8. A Wayfinding Plan shall be developed indicating the following: a. Location and wording of directional signage for vehicles and pedestrians; b. Location of building address numbers; c. Landscaping details for areas near any signage or address numbers, including elevation showing trees near exterior address numbers; d. Required lighting level on address numbers. e. The plan shall include design drawings or exhibits that clearly illustrate the intent of the Wayfinding Plan. M. Elevators shall be designed as follows: 1. Elevator cabs, the interiors of which are not completely visible when the door is open from a point centered on and 36 inches away from the door, shall have shatter resistant mirrors or other equally reflective material so placed as to make visible the entire elevator cab from this point. The elevator cab shall be illuminated at all times with a minimum maintained two foot-candles of light at floor level. 2. Elevator emergency stop buttons shall be so installed and connected as to activate the elevator alarm when utilized.

(Ord. No. 25-26, § 6(Exh. E), 11-12-25)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.