For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-9-518 — Special parking facilities provisions

Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Municipal Code § 5-9-518

Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/9bfcad39-1b44-47ac-8723-8bb27fb89695

Sec. 5-9-518. - Special parking facilities provisions.

A structure, garage or covered parking surface intended primarily for the storage of motor vehicles for any period of time, except for residential carports, shall comply with this section. A. Remote or detached parking facilities or any other parking surfaces which are constructed as a separate entity shall be assigned a street address number. Addressing for parking structures shall conform to the following specifications: 1. Numerals shall be mounted on the wall, no higher than 30 feet, and face the street on which the building is addressed. Numerals are to be clearly visible from this same street and not obscured by landscaping. The numerals shall be placed in such a location that it is evident the parking structure has this address or, when not visible from the street, numerals are to be located on a corner of the structure and not over the vehicle entrance. If references to the parking structure servicing a particular building are over the entrance, such references are to include wording clearly identifying parking for a particular building so as not to confuse the structure address with the building address. Numbers and any lettering shall be of a color contrasting to the background to which they are affixed. Method of attachment shall not include the use of two-sided tape or any material not resistant to weather conditions. 2. Numerals shall be no less than six inches in height, using a Sans Serif font with a stroke weight of medium to bold, or approved equivalent font, which is clearly legible, and shall be illuminated during the hours of darkness using a light source provided with an uninterruptible A.C. power source or controlled only by a photoelectric device, which may be the common area site lighting. 3. Residential parking structures only shall be provided with rooftop addressing to meet the requirements as specified in Section 5-9-517(L)(6). Nonresidential parking structures shall not have rooftop addressing. B. Restrooms shall not be open to the general public and shall be continuously locked, with access provided only to authorized individuals. They shall be located in an area which is highly visible from the parking attendant kiosk or other area where natural surveillance is afforded. C. Signs shall be developed in order to facilitate safe and efficient movement within the parking facility and designed as follows: 1. Signs shall be installed identifying elevators and stairwells with lettering at least ten inches in height, mounted not less than eight feet from floor level, and clearly visible within the parking facility. 2. Parking facilities with at least 300 parking spaces per floor shall provide additional signage as follows: a. Floor and section identification signs shall be placed at least every 75 feet and have numerals/letters at least ten inches in height, with section identification at least eight inches in height. The placement, quantity and orientation of these signs should allow vehicle and pedestrian users to maintain an ongoing awareness of their location with the bottom of the sign copy placed at least six feet above the parking surface. b. Wayfinding signs directing persons to elevators and stairwells are required when the elevator or stairwell is greater than 100 feet away from a parking space. Signs shall be highly visible and placed at least six feet above the parking surface. The signs shall have text of at least four inches in height utilizing a Sans Serif font with stroke weight of medium to bold. c. Residential parking garages shall have signage mounted above stairway doors/openings and elevator lobbies, containing the range of addresses or unit numbers serviced by that stairway. The signs shall have text of at least four inches in height utilizing a Sans Serif font with stroke weight of medium to bold. d. A Wayfinding-Directional signage plan, demonstrating compliance with this section, shall be developed as part of the construction plans. D. Structures or fencing designed to screen trash enclosures from public view shall be designed with no more than three solid walls and an access gate(s). They shall be designed in such a manner as to allow a maximum of six inches clearance between trash bins, walls and gates. E. Bicycle storage areas shall be designed and protected as follows: 1. Located in areas highly visible to users of the facility. 2. Bicycle racks in residential complexes shall be protected by see-through metal fencing which either fully encloses the racks with fencing or have floor to ceiling fencing, and secured either with an access control system locking device or mechanical door lock. Padlocks are prohibited. 3. The bicycle storage room shall be illuminated with a minimum maintained two foot-candles of light on the floor at all times. 4. The bicycle storage room shall have a camera surveillance system complying with the following standards: a. High-Definition color cameras shall be installed to view the entire room and shall clearly capture the entire person and a recognizable face image. b. Camera images shall be digitally stored for at least 30 days. c. A camera surveillance plan noting the type and mounting height of cameras, demonstrating compliance with this section, shall be developed as part of the construction plans. F. Automated Teller Machines are prohibited from being installed inside a parking structure or garage. G. Solid perimeter walls shall be either full height floor to ceiling or not exceed 42 inches in height from the parking surface and where applicable comply with Section H. below. H. The number of pedestrian and vehicular access points shall be minimized. Except at vehicle and primary pedestrian openings, the structure shall be designed, to the satisfaction of the City, to preclude human entry from any exterior accessible surface to a height of eight feet. Chain link fencing shall not be utilized if visible from a public right of way. When required, fire authority openings in the form of swing-out gates shall be provided and secured by a padlock with a minimum ⅜-inch diameter shackle and five-pin tumbler operation. I. Exterior pedestrian doors which provide access into the parking facility shall be constructed and equipped as follows: 1. A minimum 18-gauge steel and equipped with automatic hydraulic closure device. 2. A minimum 100-square-inch vision panel, with the width not less than five inches, to provide visibility into the area being entered. Vision panels shall meet requirements of the California Building Code. 3. Vision panels shall preclude manipulation of the interior locking device from the exterior. 4. No openings within 24 inches of the locking device which would allow a piece of metal, 1/16 -inch diameter or greater to be inserted and access gained to the interior side of the door. 5. When panic hardware is required, it shall have a self-locking mechanism and be constructed/equipped as follows: a. Panic hardware on pairs of doors shall contain a minimum of two locking points on each door; or b. On single doors, panic hardware may have one locking point, which is not located at either the top or bottom of the doorframe. When mortise hardware is utilized, a protective astragal consisting of a minimum 0.125-inch thick steel shall be attached to the exterior of the door and rendered nonremovable from the exterior. It shall be two inches wide and extend a minimum of five inches above and below the strike opening and extend a minimum of one inch beyond the edge of the door; or c. Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point, which will close the opening between them, but not interfere with the operation of either door. Fire rated astragals, meeting specifications of the California Building Code, shall be utilized when required. Astragals are not required when panic hardware is utilized with push pads offset a minimum of three inches from the door edges. 6. Emergency exits not intended as a primary entrance shall have no exterior handles, knobs, or levers. 7. Hinges shall be equipped with nonremovable hinge pins or a mechanical interlock to preclude removal of the door from the exterior by removing the hinge pins. J. Stairways shall be designed as follows: 1. Interior doors shall have glazing panels a minimum of five inches wide and 20 inches in height and meet requirements of the California Building Code. 2. Areas beneath stairways at or below ground level shall be fully enclosed or access to them restricted. 3. Stairways shall be designed to be completely visible from either the interior or exterior or both, unless mandated by the California Building Code to be enclosed. 4. Fully enclosed interior or exterior stairways with solid walls, when required, shall have shatter resistant mirrors or other equally reflective material at each level and landing and be designed or placed in such a manner as to provide visibility around corners. K. Elevator cabs and lobbies shall be designed as follows: 1. Elevators which serve more than two floors, above ground level, with at least one shaft wall exposed to the exterior shall have clear glazing installed in one exterior wall to provide visibility into the elevator cab. 2. Elevator cabs, the interiors of which are not completely visible when the door is open from a point centered on and 36 inches away from the door, shall have shatter resistant mirrors or other equally reflective material so placed as to make visible the entire elevator cab from this point. The elevator cab shall be illuminated at all times with a minimum maintained two foot-candles of light at floor level. 3. Elevator emergency stop buttons shall be so installed and connected as to activate the elevator alarm when utilized. 4. Elevator lobbies, if enclosed, shall be constructed of glazing, the maximum amount allowed by the California Building Code. L. Lighting of driveways, parking areas, walkways and doors shall conform to the following standards: 1. All parking, driving, and walking surfaces, except stairways, shall be illuminated at all times with a minimum maintained 1.25 foot-candles of light. Exceptions: 1. Parking facilities which have physically precluded pedestrian and vehicle access during non-business hours may provide a minimum maintained 0.25 of light on the parking, walking and driving surfaces. 2. Open roof top parking may be illuminated to a minimum maintained one foot-candle of light on the parking and walking surface. 2. Stairways shall be illuminated at all times with a minimum maintained two foot-candles of light on all landings and stair treads. 3. All types of exterior doors shall be illuminated, during the hours of darkness, with a minimum maintained one foot-candle of light, measured within a five- foot radius of each side of the door at ground level. 4. Recessed areas of buildings or fences, which have a minimum depth of two feet, a minimum height of five feet, and do not exceed 6 feet in width and are capable of human concealment, shall be illuminated with a minimum maintained 0.25 foot-candle of light at ground level during the hours of darkness. This requirement applies to defined recessed areas which are within six feet of the edge of a designated walking surface with an unobstructed pathway to it, not hindered by walls or hedge row landscaping a minimum of two feet in height. 5. All luminaires utilized to meet the requirements of this section shall have fully enclosed vandal resistant light fixtures, if on the exterior, with no portion of the fixture placed less than eight feet above the walking or driving surface. 6. The light source utilized to comply with this section shall have rated average bulb life of not less than 20,000 hours, not battery operated, and controlled by a photocell device or a time clock with an astronomic feature. 7. Light fixtures may utilize motion sensing devices to raise and lower the light levels based upon the presence of vehicles or people. The light level shall not be less than a minimum maintained 0.5 foot-candle of light at ground level when not occupied. The devices shall be adjusted to sense and activate a light when a vehicle or person is within 24 feet of the fixture. Areas within a 50-foot radius of an elevator lobby/doors and stairways shall not fall below the required minimum maintained 1.25 foot-candles of light. 8. A site plan shall be provided, and approved by the City, showing buildings' parking area, walkways, detailed landscaping, with tree legend (if pole lights are used) and shrub legend (if bollards are used), fixture schedule, mounting height, lighting ratio and a point-by-point photometric calculation of the required light levels. If a parking lot is equipped with an occupancy sensor, then a point-by-point photometric calculation is required to show it meets the required minimum level of light. Foot-candles shall be measured at grade on a horizontal plane and conform to a uniformity ratio of six to one (6:1) average/minimum. Landscaping shall not be planted so as to obscure required light levels with light fixtures exceeding eight feet in height installed at least two feet from a tree's canopy at 70 percent maturity. M. Landscaping around the perimeter of the structure shall not provide access to any portion of the structure unless the accessible point is protected as described in Subsection H hereinabove. N. Residential parking structures and garages shall have a camera surveillance system complying with the following standards: 1. High-Definition color cameras shall be installed at all vehicle and pedestrian entrances, all elevator lobbies, bicycle and motorcycle storage areas and be capable of clearly capturing an entire vehicle including license plate and driver's face. Cameras at pedestrian entrances, elevator lobbies and bicycle storage areas shall clearly capture the entire person and a recognizable face image. 2. Camera images shall be digitally stored for at least 30 days. 3. A camera surveillance plan noting the type and mounting height of cameras, demonstrating compliance with this section, shall be developed and approved by the City as part of the construction plans.

(Ord. No. 25-26, § 6(Exh. E), 11-12-25)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.