Sec. 5-9-519. - Emergency access.

The provisions of this section shall apply to new construction and any modifications or replacements made to existing emergency access key vaults, key switches, or radiocontrolled entry systems. A. Private roads and parking areas or parking facilities, when controlled by unmanned automated parking gates, shall provide for police emergency access, at all individual gates, both ingress and egress, utilizing an approved radio-controlled entry system and approved key switch device to be installed and designed as follows: 1. The key switch control shall be installed at a height of 42 inches from finished driveway grade and a minimum of 15 feet from the entry/exit gate and be located on the driver's side of the road or driveway. The key switch is to be accessible in such a manner as to not require a person to exit their vehicle to reach it; nor to require any back-up movements in order to enter/exit the gate. The control housing may be mounted on a wall or pillar in a parking structure. The key switch may be installed within a visitor telephone/intercom call box if meeting the above criteria. The key switch control housing shall consist of heavy gauge metal, be vandal- and weather-resistant and be mounted on a substantial structure such as a steel post, concrete, or masonry pedestal. 2. Key switches shall be secured to the control housing, telephone/intercom call box or parking ticket dispenser utilizing tamper resistant screws. 3. Except for an open surface parking lot with less than 100 parking spaces, a radio-controlled entry system shall be installed per City specifications. 4. Vehicle gates shall be designed to open in a power failure. 5. Vehicle gates shall be illuminated during the hours of darkness, with a minimum maintained one foot-candle of light, measured 25 feet on each side of the gate at ground level. The light source shall be controlled by a photocell device or a time clock with an astronomic clock feature and capable of operating during a power outage. B. All lockable pedestrian gates or doors to exterior and interior common area walkways, fire department emergency access pathways, mailrooms, and recreation areas/buildings of residential multifamily complexes or tract of homes shall provide for police emergency access utilizing an approved radio-controlled entry system and approved key switch device or approved key vault which shall be installed as follows: 1. Pedestrian gates or doors utilizing an electrically automated type lock shall be provided with an approved radio-controlled entry system and a key switch. The key switch shall be affixed with tamper resistant fasteners, mounted next to the access control reader, or installed within a telephone/intercom console, or mounted at a height of four to five feet above the finished grade or floor in a control housing as described in section A.1. above, or in a method approved by the Enforcing Authority. The radio-controlled receiver shall be visible in order to determine, when activated, if the signal was received by illuminating a light. More than one gate or door, which is in close proximity to another, may be operated by a single radio-controlled entry system, if approved by the Police Department. Exceptions: 1. Recreation buildings/rooms are not required to have a radio-controlled entry system. 2. Interior stairway doors which are not a primary or common method to enter the building and designed as emergency exits, are not required to have a radio-controlled entry system. 2. Pedestrian gates or exterior doors utilizing mechanical locks shall be provided with a key vault adjacent to each gate or door, securely attaching it to a fence or wall, mounted five feet above finished grade and within two feet of the locking device. Mechanical locks using combination locks shall have a keyway and key for the key vault. 3. Pedestrian gates, not adjacent to vehicle gates and located in perimeter community walls or fencing, and is using an electronically automated type lock, shall utilize a key switch, affixed with tamper resistant fasteners, mounted next to the access control reader; or, if a mechanical lock is used, then a key vault, mounted five feet above finished grade and within two feet of the locking device is required. 4. Pool gates with electronically automated type lock, shall utilize a key switch, affixed with tamper resistant fasteners, mounted next to the access control reader. If the gate does not automatically unlock when losing power then, it is to also have a mechanical lockset, and key vault, mounted five feet above finished grade and within two feet of the locking device and contain the mechanical key for the gate. 5. Elevators with access control systems shall install a key switch adjacent to the access control reader utilizing tamper-resistant screws. C. Nonresidential multi-tenant buildings and hotels with a common area entrance shall provide police emergency access utilizing an approved radio-controlled entry system and approved key switch device or approved key vault which shall be installed as follows: 1. All common area, exterior and interior doors, using an electrically automated type lock shall be provided with a key switch device within the building's exterior telephone/intercom call box, adjacent to an access control reader, or in a control housing as described in section A.1 above, or in a method approved by the Enforcing Authority, and located within close proximity and in a visible area near the door, mounted four to five feet above finished grade or floor. Key switches shall be secured utilizing tamper resistant screws. A radio-controlled entry system is only required at all primary entry doors. 2. Exterior entry common area doors utilizing mechanical door locks shall be provided with a key vault mounted five feet above finished grade and within two feet of the locking device. 3. Hotels shall have a keyswitch at all building entrances with electrically automated type locks accessible to the hotel guests and mounted adjacent to the access control reader. Doors when equipped with both panic hardware and mechanical locks, shall have a key vault mounted five feet above finished grade and within two feet of the locking device. A radio-controlled entry system is not required. 4. Elevators with access control systems shall install a key switch adjacent to the access control reader utilizing tamper resistant screws. D. Emergency vehicle access gates shall be designed so as to provide access to the padlock from either side of the gate. A key vault shall be installed on the interior and exterior side of the gate, mounted five feet above finished grade and within two feet of the locking device. Owner's padlock shall be used to secure the gate. E. Non-residential businesses or facilities with vehicle gates requiring a key vault or padlock by the Orange County Fire Authority, shall be keyed per Section 5-9-519(G). F. Lockable doors to the roof of multi-tenant residential and non-residential buildings and hotels shall have a key vault. G. All key switches, key vaults, and padlocks shall be sub-mastered to an Orange County Fire Authority key for access by the Police Department. The radio-controlled entry system shall be programmed to frequencies approved in writing by the Police Department and the Orange County Fire Authority. H. Key switches containing a label for operating the switch, key vaults, padlocks, and radio-controlled entry systems shall be installed per manufacturer's instructions and are clearly identifiable to approaching police personnel in a manner as approved by the Police Department. I. An Emergency Access Plan, approved by the Police Department, shall be required when a radio-controlled entry system, key switch, or key vault is required to be installed. The Plan shall identify the location of each device on a site plan.

(Ord. No. 25-26, § 6(Exh. E), 11-12-25)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.