For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-9-520 — Special recreational spaces provisions

Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Municipal Code § 5-9-520

Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/875b6f9d-a165-47a9-a63f-35bdc3ad9e96

Sec. 5-9-520. - Special recreational spaces provisions.

The provisions of this section shall apply to all public and private community buildings, parks, open spaces, trails, community swimming pools, recreation centers, and associated sidewalks and parking lots. A. Structures shall comply with all provisions of the Uniform Security Code except Section 5-9-517(K), Special nonresidential building provisions, regarding lighting standards. B. Exterior lighting shall conform to the following standards: 1. All types of exterior doors shall be illuminated during the hours of darkness with a minimum maintained one foot-candle of light at ground level, measured within a five-foot radius from the center of the door. 2. Recessed areas of buildings or fences, which have a minimum depth of two feet, a minimum height of five feet, and do not exceed six feet in width and are capable of human concealment, shall be illuminated with a minimum maintained 0.25-foot candle of light at ground level during the hours of darkness. This requirement applies to defined recessed areas which are within six feet of the edge of a designated walking surface with an unobstructed pathway to it, not hindered by walls or hedge row landscaping a minimum of two feet in height. 3. Stairways shall be illuminated with a minimum two foot-candles of light on all landings and stair treads, during the hours of operation, including one hour thereafter. 4. Parking lots and walkways accessing buildings and parking areas shall be illuminated with a minimum maintained one foot-candle of light on the driving or walking surface during the hours of operation and one hour thereafter. 5. Bike trails not incorporated in the roadway shall be illuminated with a minimum maintained 0.25 foot-candle of light at ground level during the hours of darkness, except that any bike trail or recreational facility within the designated Natural Community Conservation Plan/Habitat Conservation Plan, Central Coastal Subregion reserve area shall be exempt from the requirements of this subsection. 6. Paved walkways in open space areas, not directly serving buildings or parking areas, shall be illuminated with a minimum maintained 0.25 footcandle of light on the walking surface during the hours of operation. 7. Swimming pool decks and other hard surface recreation activity areas shall be illuminated with a minimum maintained 0.50 foot-candle of light on the walking surface during the hours of operation and one hour thereafter. 8. The light source utilized to comply with this section shall have a rated average bulb life of not less than 20,000 hours, not battery operated, and controlled by a photocell device or a time clock with an astronomic feature. 9. Luminaires utilized to meet the requirements of this section shall have fully enclosed vandal resistant light fixtures, if accessible, and be not less than eight feet in height from ground level. A luminaire not less than 42 inches may be utilized to illuminate a walkway if adjacent landscaping is of a variety which does not mature higher than two feet, and it does not interfere with the required light distribution for a distance of 16 feet along the walkway. Light fixtures shall be deemed accessible if mounted within 15 feet vertically or six feet horizontally from any accessible surface or any adjoining roof, balcony, landing, stair treads, platform or similar structure. 10. Lighting near basketball courts shall be designed so as to eliminate or greatly minimize illuminating the courts. 11. Activation of the required exterior lighting shall be either by a photocell device or a time clock with an astronomic clock feature. 12. A site plan shall be provided showing buildings, parking area, walkways, detailed landscaping, with tree legend (if pole lights are used) and shrub legend (if bollards are used), fixture schedule, mounting height, lighting ratio and a point-by-point photometric calculation of the required light levels. Foot-candles shall be measured at grade on a horizontal plane and conform to a uniformity ratio of six to one (6:1) average/minimum. Landscaping shall not be planted so as to obscure required light levels with light fixtures exceeding eight feet in height installed at least two feet from a tree's canopy at 70% maturity. 13. Public recreation facilities and spaces shall utilize light poles and fixtures listed on the Irvine Community Services Department approved products list. C. Swimming pools shall be secured as follows: 1. Restroom doors and pool gates shall be equipped with automatic closure devices, dead latches, and a latch protector consisting of minimum 0.125- inch thick steel, two inches wide and six inches long. 2. The pool equipment room shall be secured as follows: a. A dead latch bolt lockset, with a minimum bolt throw of ¾ inches, operated either mechanically or electrically with a protective plate constructed of steel 0.125 inch thick, which shall be attached with nonremovable bolts to the outside of the door. The plate shall extend a minimum of 6 inches vertically above and below the latch of the panic hardware. The plate shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached; or b. A deadbolt lockset as specified in Section 5-9-517(B) which can be either operated mechanically or electrically. 3. The on and off switch for the spa is to be keyed or access controlled. 4. Perimeter fencing, using either tubular steel or aluminum, is to be installed at a minimum height of six feet. Vertical fence pickets are to be spaced not more than four inches on-center and be designed to discourage climbing. 5. Emergency access to locked gates is to be provided through installation of a Knox box key vault which shall contain a mechanical key for the gate. The vault shall be sub-mastered to the Orange County Fire Authority for access by the Police Department. The mounting location shall be five feet above finish grade and within two feet of the locking device. Pools with double gates shall have the key vault installed as close as possible to the hinge side of one gate. Gates shall utilize a mechanical lock with the gate key placed inside the key vault. Exception: If it is not practical to install the key vault within two feet of locking device due to structural issues, then it may be mounted within four feet of the locking device. 6. Selection of landscaping is to consider height of plants regarding providing needed visibility into the pool area from adjacent uses, buildings, and streets. 7. Lighting shall conform to Section 5-9-517L.8 regarding lighting fixtures. 8. Private park pools/spas, which may be reached by the general public, shall have signage indicating it is private property and no trespassing allowed, citing the current Penal Code section for trespassing. 9. Address numbers, when assigned, shall be visible from inside and outside the pool, and the numerals and street name shall be at least four inches in height using Sans Serif font with a stroke weight of regular to medium, or an approved equivalent font which is clearly legible. 10. Showers shall be located in highly visible areas outside and not inside a building and not be obscured by wing walls greater than 42 inches in width. D. Landscaping and amenity guidelines and requirements are as follows: 1. Plant materials and walls shall take into consideration the need for users of the space to easily view their surroundings as well as police patrols to monitor the area from adjacent streets. Plants should be selected which do not grow beyond a height of 42 inches. 2. Trees shall be positioned to avoid interfering with required lighting levels and take into consideration the height of canopies from ground level regarding surveillance opportunities by users of the space and police patrols. 3. Planting of wide hedge rows and narrow vertical plants adjacent to solid fences is encouraged. 4. In public parks, planters at least two feet in length and under 42 inches in height, which are directly adjacent to a cement or asphalt walking or driving surface, shall have devices attached to the outer edges which are designed to discourage skateboard grinding (vandalism) or the edges shall be designed in such a manner as to deter such grinding. 5. Park benches are to be designed to deter laying upon them which may include a center arm rest or similar design feature. E. Park identification signs shall be provided at all public and private parks as follows: 1. Parks and private recreation facilities shall have a park identification sign, with address number, street name, park name, and the word "Private" if it is a private park. The sign copy size shall be a minimum height of six inches for the park name, a minimum of four inches for the address number and street name, and a minimum three inches for "private". The sign copy shall be of a color contrasting to the background to which they are affixed. Signs shall be highly visible and placed within 100 feet of the centerline of the addressed street. Bottom line of the sign copy shall be no less than two feet from ground level and not obstructed by landscaping or by parked cars. Public Park identification signs also must meet the design criteria adopted in the City's Park/Public Facility Design Standards. 2. Landscaping in front of the park signage shall be of a variety which grows to no more than two feet in height. 3. Park shall not have duplicate names or names that sound similar to existing parks. F. Trail and park connections to neighborhoods shall be identified as follows: 1. Pedestrian connections from trails, parks, and open space areas into adjacent neighborhood public or private sidewalks and streets shall have a City street sign or other approved sign identifying the street where the connection occurs. 2. Trails crossing public or private streets shall have a City street sign at the intersection of the trail and street identifying the street and trail names. 3. Named City trails shall have markers placed on concrete or asphalt surfaces every one-tenth of a mile and shall meet the design and application criteria as established by the Community and Library Services Department. G. Private and public space delineation shall be provided as follows: 1. When private and public spaces are shared, there shall be a clear delineation between the two entities. Signage and physical markers shall make it clear where the property line extends between the City owned property and private property. H. Dog parks. Enclosed spaces designed for dogs to be off-leash shall conform to the following standards: 1. The dog park shall be located in a highly visible area. 2. Perimeter of the dog park shall have a fence, at least five feet in height, with no more than 40 percent of it being of solid construction. Fencing shall be tubular steel with openings between pickets not more than three inches in width, and designed to prevent dogs from crawling under it. 3. Gates shall be a double gated entry system where one gate must be closed before the other can be opened. 4. Access to the dog park is to be controlled by an access control system if park is part of a residential complex. Emergency access is to be provided for police and fire departments per Section 5-9-519(B). 5. Provide waste bag station and trash container. 6. All surfaces of the enclosed fenced portion of the dog park shall be illuminated with a minimum maintained 0.5 foot-candle of light at ground level, during the hours of operation, including one hour thereafter. Parking lots and walkways shall be illuminated per Section 5-9-520(B). and a photometric lighting plan provided prior to the issuance of building permits. a. The light source utilized to comply with this section shall have a rated average bulb life of not less than 12,000 hours. b. A site plan shall be provided, and approved by the City, showing the park, buildings, parking area, walkways, detailed landscaping with tree legend (if pole lights are used) and shrub legend (if bollards are used), fixture schedule, mounting height, lighting ratio and a point- by-point photometric calculation of the required light levels. If the park is equipped with an occupancy sensor, then a point-by-point photometric calculation is required to show it meets the required minimum level of light. Foot-candles shall be measured at grade on a horizontal plane and conform to a uniformity ratio of six to one (6:1) average/minimum. Landscaping shall not be planted so as to obscure required light levels with light fixtures exceeding eight feet in height installed at least two feet from a tree's canopy at 70 percent maturity. I. Privately owned, publicly accessible parks. 1. Privately owned parks, open to the public as deemed by the City, shall develop a security operations plan to monitor and control the park. Plan shall include addressing the following issues: noise, loitering, hours of operation, violation of owner's rules and regulations, High-Definition cameras for recording activity, and the on-site title(s) of persons responsible for enforcement of the security operations plan. 2. Park identification signs shall conform to Section 5-9-520(E), with the following change in type of park identified: "Private Open to Public". 3. Signs shall be installed at all pedestrian walkway entrances to the park which state: "Park is privately owned, open for public use, controlled and maintained by the property owner." J. Rooftop recreational spaces. 1. Recreation spaces located on top of parking structures or residential units shall have a camera surveillance system complying with the following standards: a. High-Definition color cameras shall be installed to view the entire recreational space and shall clearly capture the entire person and a recognizable face image. b. Camera images shall be digitally stored for at least 30 days. c. A camera surveillance plan noting the type and mounting height of cameras, demonstrating compliance with this section, shall be developed as part of the construction plans.

(Ord. No. 25-26, § 6(Exh. E), 11-12-25)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.