§ 5-9-521 — Construction site and vacant property security
Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Municipal Code § 5-9-521
Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/61924d1c-b045-439f-9bae-8babae029da0
Sec. 5-9-521. - Construction site and vacant property security.
A. Scope of construction site and vacant property security. The provisions of this section shall apply to residential and nonresidential developments and vacant property as follows: 1. "Construction site" shall mean any site, excluding a single residential lot and additions and alterations to existing nonresidential structures, upon which construction or demolition work is occurring, or upon which such work has commenced but has not been completed. The provisions of this section shall apply from the time raw building materials are placed on the site until the installation of all building fixtures is completed. 2. "Vacant property" shall mean any property more than 20 acres in area where there are buildings or other facilities of any type that have been abandoned or are otherwise not in use for a period of more than 30 calendar days, except that a residential lot shall not be deemed to be a vacant property merely by virtue of the fact that a home on the property is currently unoccupied. B. Construction site general security requirements. 1. The owner of a construction site shall implement those security measures reasonably necessary to control access to the site, and to deter vandalism, theft, and other crime. 2. Access points: The number of access points onto the site shall be minimized and, where feasible, situated in locations that are highly visible from an adjacent street. 3. Perimeter construction site fencing shall be installed adjacent to streets and designed as follows: a. Chain link or other metal fencing and gates, at least six feet in height, covered with green 94 percent minimum blackout heavy duty plastic screening material; and (1) Vehicle and pedestrian access gates shall not be covered. Fencing shall not be covered for the first 20 feet in lineal length, or greater where necessary for sight distance control, on each side of a gate. b. All vehicle and pedestrian openings shall have gates secured after hours of operation by a padlock(s) designed to prohibit cutting of the shackle; and (1) Coil chain, minimum 30 grade, at least ⅜-inch thick, if used to secure a gate; or (2) Cable at least 5/16 -inch thick, if used to secure a gate. c. Perimeter fencing may be removed when there is no longer outside storage of building materials or building fixtures and when there are no remaining exterior construction activities requiring separation of non-construction related personnel and public from exterior construction activity. d. Alternative fencing and protection may be approved in writing by the Chief of Police or Chief Building Official. e. Emergency access Knox Boxes, when required by the Orange County Fire Authority, shall be sub-mastered to an Orange County Fire Authority key for access by the Police Department. 4. Office trailers and temporary buildings shall be secured as follows: a. At a minimum, doors shall have a deadbolt lock per Section 5-9-517B.1 and an auxiliary locking device using a hasp or slide bolt with a protective device to prohibit cutting of a padlock, attached with nonremovable bolts from the exterior, and locked with a padlock having a minimum ½-inch thick shackle with heel and toe locking; or secured in a manner as approved in writing by the Chief of Police. b. All windows shall be secured from entry using either: (1) Steel bars of at least ½-inch round or one-inch by ¼-inch flat steel material, spaced not more than five inches apart, securely attached on the inside of the trailer using bolts that are nonremovable from the exterior; or (2) Steel grate mesh of at least ⅛-inch thick material, securely attached on the interior or exterior of the trailer using means that are resistant to removal from the exterior. 5. Storage containers with at least 64 square feet of storage area shall be secured as follows: a. Doors shall be secured using a hasp or slide bolt with a protective device to prohibit cutting of the padlock, attached with nonremovable bolts from the exterior, and locked with a padlock having a minimum ½-inch thick shackle with heel and toe locking; or secured in a manner as approved in writing by the Chief of Police. b. Exterior hinge pins shall be rendered nonremovable by design or welding. 6. Site lighting shall be installed and designed as follows: a. Where lighting required by the provisions of 6.b through 6.e below would impinge on occupied residential properties: (1) Motion sensors may be used to control light fixtures. (2) Elements of the lighting provisions 6.b through 6.e below may be modified or not required when approved by the Chief Building Official or Chief of Police. b. All vehicle gate locations shall be illuminated, during the hours of darkness, with an approximate minimum maintained one foot-candle of light on the ground, within and on all sides of the gated opening for a distance of 15 feet beyond the opening. Outdoor lighting shall be maintained and installed so that direct rays are confined to the site and adjacent properties and streets open to the public are protected from glare. c. All open centralized storage areas for building materials or building fixtures shall be illuminated, during the hours of darkness, with an approximate minimum maintained one foot-candle of light on the ground, within and on all sides of the stored items for a distance of 15 feet beyond the materials or fixtures. d. All trailers, temporary buildings, or containers used as an office or for storage of building materials, or fixtures for buildings, or construction equipment shall be illuminated on all sides with openings, during the hours of darkness, with an approximate minimum maintained one foot-candle of light on the ground for a distance of 15 feet beyond the exterior walls. e. Luminaries utilized to meet this section shall be installed at least 18 feet from the ground, have tempered or polycarbonate lenses, and meet or exceed U.L. Bulletin 1572 for wet locations. f. When Southern California Edison power is not available the following temporary alternatives shall be utilized until such power is on site: (1) Portable power generators that meet City noise requirements for construction sites during non-working hours; or (2) Battery or solar operated lights which illuminate the doors of construction trailers, tool bins, and raw materials storage. 7. Forklifts shall be rendered inoperable, when hours of operation are ceased, by removing the key and adding a device to either disable the engine or other measure to prohibit moving it. 8. A record shall be developed and maintained of on-site motorized construction vehicle equipment, which have wheels a minimum of 15 inches in diameter, listing the manufacturer, model, license plate number, vehicle identification number (VIN), and product identification number (PIN). 9. An address sign shall be installed at all perimeter vehicle access points and include the street address and tract number, using minimum six-inch high letters and numbers, and shall be posted at the top of the perimeter fence or at least five feet from the ground. 10. A "No Trespassing" sign, conforming to the requirements of California Penal Code Section 602, shall be installed at all perimeter access points, posted at the top of the perimeter fence or at least five feet from the ground. 11. A 24-hour emergency phone number, for management of the site, shall be posted at the main gated entrance and on the exterior of an on-site office trailer or building near the main vehicle entrance. 12. Residential units shall not have appliances installed until the home can be completely secured and locked. C. Construction site security plan. 1. A security plan shall be required if the residential construction site has 15 or more dwelling units, or a nonresidential construction site has 50,000 square feet or more of building area. Residential building area is considered the same builder within a master tract regardless if the units are contiguous. 2. A security plan shall be submitted as part of the normal and customary building permit application and review process for review and approval prior to issuance of building permits. 3. A security plan shall include the requirements in Section 5-9-521.B and the following: a. Description of the construction site including: Location, size, boundaries, type of project, overall site plan, access points, office/storage locations, and contact person responsible for implementing the security plan. b. A copy of the approved security plan shall be maintained at the site to show the original location of site security elements and any changes made thereto to adjust to changing field conditions. c. Institute at least one of the following additional security measures: (1) Provide color cameras that view all vehicle access points and record vehicle license plates when the hours of operation cease, saving recorded activity for at least 60 days; or (2) Utilize one California State Licensed Security Guard for every 10 contiguous acres of the same project or portion thereof, to monitor the site when hours of operation cease, recording persons and vehicles entering and leaving it, saving recorded activity for at least 60 days; or (3) Compliance with a construction site security program approved by the Chief of Police in writing that addresses: Identification and marking of equipment and construction materials; inventory of construction equipment; key control; alarm system for trailers/storage containers; materials inventory control procedure; securing tools/equipment; securing vehicles and large pieces of equipment; perimeter security of construction site; lighting; liaison with law enforcement; or (4) Other alternate measure(s) approved by the Chief of Police that are found to provide at least the equivalent security of providing one of measures (1), (2), or (3) above. d. Develop a written procedure and implement a property identification program approved by the Chief of Police that is designed to readily identify ownership of heavy equipment, building materials where feasible, and building equipment. 4. As part of the security plan review and approval process, the Chief of Police or the Chief Building Official may require modifications to the security plan when: a. The plan fails to comply with any of the requirements set forth in the provisions of this chapter in any respect; b. The security measures described in the plan are insufficient to meet the security needs of the particular site; or c. The security personnel are unqualified to meet the security needs of the particular site. D. Vacant property general security requirements. 1. All security measures taken to secure vacant properties shall be consistent with Chapter 6 of Division 11 of Title 4 of the Municipal Code regarding minimum property maintenance standards. 2. Access points: The number of access points onto the site shall be minimized and placed in locations that are highly visible from an adjacent street. 3. Perimeter fencing shall be installed around the entire site and designed as follows: a. Chain link or other metal fencing and gates, at least six feet in height, covered with green 94% minimum blackout heavy duty plastic screening material; and (1) A 20-foot-wide opening in the material every 400 lineal feet; and (2) Vehicle and pedestrian access gates shall not be covered. Fencing shall not be covered for the first 20 feet in lineal length, or greater where necessary for sight distance control, on each side of a gate. b. All vehicle and pedestrian openings shall have gates secured after hours of operation by a padlock(s) designed to prohibit cutting of the shackle; and (1) Coil chain, minimum 30 grade, at least ⅜-inch thick, if used to secure a gate, or (2) Cable at least 5/16 -inch thick, if used to secure a gate. c. Alternative fencing and protection may be approved in writing by the Chief of Police or Chief Building Official. 4. An address sign shall be installed at all perimeter vehicle access points and include the street name and number, and tract number, using minimum 6- inch-high letters and numbers, and shall be posted at the top of the perimeter fence or at least five feet from the ground. 5. A "No Trespassing" sign, conforming to the requirements of California Penal Code Section 602, shall be installed at all perimeter access points, posted at the top of the perimeter fence or at least five feet from the ground. 6. A 24-hour emergency phone number, for management of the site, shall be posted at the main gated entrance and on the exterior of a building or office trailer near the main vehicle entrance. 7. Based upon an evaluation of the site by the Chief of Police or Chief Building Official, a security plan meeting the requirements of Subsection C above may be required if deemed necessary in order to ensure the safety and security of the vacant property.
(Ord. No. 25-26, § 6(Exh. E), 11-12-25)
Ask a question about Irvine law
Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.
