15.30.200 - Structural weaknesses.
A. Structural weaknesses shall include the following: 1. Sill plates or floor framing supported directly on the ground without an approved foundation system. 2. Perimeter foundation constructed of wood posts supported by isolated footings. 3. Perimeter foundation that is not continuous. Exception: existing porches, storage rooms, and similar spaces that do not contain fuel-burning appliances. 4. Perimeter foundation constructed of unreinforced concrete or assembled masonry. 5. Sill plates not connected to the foundation in accordance with this Chapter. 6. Cripple walls not braced in accordance with this Chapter. B. A separate permit for strengthening structural weaknesses set forth in Sections 15.30.200(A)(1) through (A)(4) (inclusive) shall be required as a condition of issuance of a permit for strengthening structural weaknesses set forth in Sections 15.30.200(A) (5) and (A)(6).
(Ord. 12812 § 1 (part), 2007)