15.30.230 - Prescriptive design—Framing.
A. Floor Joists—End Bearing. End bearing of floor joists shall be restrained by a continuous rim joist (two-inch nominal thickness), or tightly-fitting, full-depth, lumber blocking (two-inch nominal thickness) or exterior grade structural wood panel sheathing (one-inch minimum thickness). Bottom edge fasteners for rim joists and perimeter edge fasteners for blocking and sheathing shall be either 8d common angled ("toe") nails spaced apart four inches or equivalent supplemental connectors. Foundation blocking or sheathing shall be installed between alternate floor joists. Cripple wall blocking or sheathing shall be installed between each floor joist, except for obstructions (piping, underfloor ventilation and access, conduits, ducts, etc.). The perimeter of supplemental blocking shall be fastened to adjoining members. B. Floor Joists—Parallel Span. Floor joists that are parallel to a perimeter foundation shall have a parallel rim joist fully supported by the foundation sill plate or cripple wall top plate. Bottom edge fasteners for rim joists shall be either 8d angled ("toe") nails spaced apart four inches or equivalent supplemental connectors.
(Ord. 12812 § 1 (part), 2007)