15.30.240 - Prescriptive design—Foundations.
A. Construction. Foundations shall be constructed in accordance with the Oakland Building Construction Code. Soil investigations or geotechnical studies shall not be required unless the building has structural distress from soil movement. B. Analysis. 1. Foundations with structural weaknesses set forth in Sections 15.30.200(A)(1) and 15.30.200(A) (2) shall be replaced with a continuous perimeter foundation. 2. Foundations with structural weaknesses set forth in Sections 15.30.200(A)(3) and 15.30.200(A) (4) shall be either a. replaced with a continuous perimeter foundation, or b. analyzed for structural adequacy by a registered design professional for force levels determined by the formula: V = 0.1375 W, where V= base shear and W= tributary weight, and approved by the Building Official. Test reports to determine existing foundation material strengths, quality, and condition shall be submitted for review.