§ 85.2.060 — Fire apparatus access roads. [Topographical and Geological]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 85.2.060
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/a98fe653-f7af-4753-8c35-09b9f45a594e
§ 85.2.060: Fire apparatus access roads. [Topographical and Geological]
Chapter 5, Fire Service Features, of the California Fire Code is adopted and/or amended to read as follows: 503.2.1.1 Dimensions Sections 503.2.1 and 503.2.1.1 Table 503.2.1-A are added to the California Fire Code to read in their entirety as follows: 503.2.1.2 Private Roads Used for Fire Apparatus Access. The minimum width of private roads which are also used for fire apparatus access shall be in accordance with Table 503.2.1-A. The minimum required width for fire apparatus access should not be used to determine the minimum width of private roads. When approved by the Fire Chief this requirement may be modified or waived. Table 503.2.1-A. Minimum Width of Private Roads Also Used for Fire Apparatus Access Location of Parking | Minimum Road Width Fire Access Only | 20'* Public Access Road | 25'* Aerial Ladder Truck Access | 30'* * Measured from clear unobstructed pathway 503.3 Fire Lane Marking/Signage. In accordance with California Vehicle Code the designation shall be indicated (1) by a sign posted immediately adjacent to, and visible from, the designated place clearly stating in letters not less than one inch in height that the place is a fire lane (2) by outlining or painting the place in red and, in contrasting color, marking the place with the words "NO PARKING FIRE LANE," which are clearly visible from the vehicle, or (3) by a red curb or red paint on the edge of the roadway upon which are clearly marked the words "NO PARKING FIRE LANE." The Fire Chief shall have the authority to designate fire apparatus access roads on private property. 505.1 Address Numbers. Approved address numbers and letters must be placed on all new and existing buildings and units in such a location as to be plainly visible and legible from the street or road fronting such buildings and units. Numbers and letters must be at least four (4) inches in height for residential, six (6) inches in height for commercial, and twelve (12) inches in height for industrial buildings and units and may not be located on doors or other areas that can be obstructed from view. The numbers and letters will be in a color that contrasts with their background and must be in the City's approved numbering sequence. Residential, commercial and industrial buildings and units that are served by an alley or a fire apparatus access roadway to the rear of the building must also have approved address numbers and letters posted in a visible location near the primary door to the alley or a fire apparatus access roadway. 507.1 Required Water Supply. The location number and type of fire hydrants connected to a water supply capable of delivering the required fire flow shall be provided on the public street or on the site of the premises or both. 507.2.1 Private Fire Hydrants. When required, private on-site fire hydrants shall be in accordance with the location and spacing specified for public streets and hydrants for similar occupancies. All private hydrants shall be installed in accordance with NFPA 24, Installation of Private Fire Service Mains and their Appurtenances, unless required to meet public standards. Private hydrants shall be painted yellow. When alternate materials or methods of protection, as approved by the Fire Chief are provided, these requirements may be modified or waived. 507.5 Fire Hydrant Systems. Section 507.5 Fire hydrant systems shall be omitted. Fire hydrants shall be accessible to the fire department apparatus by roads meeting the requirements of Section 503. 507.5.1 Public Fire Hydrants. When required by the Fire Chief, there shall be one or more public fire hydrants installed at each street intersection in all developed areas of the city. The necessity for more than one hydrant located at each intersection on both sides of the street will depend upon required fire flows, street widths, center dividers or other physical barriers and existing or anticipated vehicular traffic volume. 1. | In industrial, commercial, high density and multi-unit residential areas, hydrant spacing shall be approximately every 300 feet along public ways. 2. | In areas where construction is limited to single family, duplex and triplex residential, hydrant spacing shall be approximately every 500 feet along public ways. 3. | In all areas where street width exceeds 80 feet, appropriately spaced fire hydrants shall be required on both sides of the street.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.