§ 85.2.150 — Appendix A - Life Safety Requirements for Existing Buildings. [Administrative]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 85.2.150
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/63612555-3202-4ae2-b256-b8c3f3fa4da8
§ 85.2.150: Appendix A - Life Safety Requirements for Existing Buildings. [Administrative]
Appendix A, Board of Appeals of the California Fire Code, is replaced with Appendix A, Life Safety Requirements for Existing Buildings. Sections A115.1, A115.3, A115.4, A115.5 and A115.6 of Appendix A of the California Fire Code are hereby added to read as follows: A115.1 Date for Compliance. Six (6) months after notification by the Torrance Fire Department or Building & Safety Department that the structure is in violation of this chapter, every building falling within its scope shall be vacated until made to conform to the requirements of this section. The Fire Chief may grant necessary extensions of time when it can be shown that the specific time periods are not physically practical or pose an undue hardship. The granting of an extension of time for compliance shall be based upon the showing of good cause and subject to the filing of an acceptable systematic progressive plan of correction with the Building Official. A115.3 Corridors. Corridors of Groups A, B, E, F, H, I, M and R, Division 1, and S Occupancies serving an occupancy load of 30 or more, shall have walls and ceilings of not less than one hour fire resistive construction as required by the code. Existing walls surfaced with wood lath and plaster in good condition or ½-inch gypsum wallboard or openings with fixed wired glass set in steel frames are permitted for corridor walls and ceilings and occupancy separations when approved. Where lath and plaster is found to be deteriorating in exit corridors, it shall be replaced or covered with ⅝ inch Type X gypsum wallboard throughout. Doors opening into such corridors shall be protected by 20-minute fire assemblies or solid wood doors not less than 1 ¾ inch thick door, a 1⅜-inch-thick solid bonded wood-core door or equivalent insulated steel door shall be permitted. Doors shall be self-closing or automatic closing by smoke detection. Transoms and openings other than doors from corridors to rooms shall comply with the California Building Code or shall be covered with a minimum of ¾ inch plywood or ½ inch gypsum wallboard or equivalent material on the room side. Exception: Existing corridor walls, ceilings and opening protection not in compliance with the above may be continued when such buildings are protected with an approved automatic sprinkler system throughout. A115.4 General. Dwelling units and hotel or lodging house guest rooms that are used for sleeping purposes shall be provided with smoke detectors. Detectors shall be installed in accordance with the approved manufacturer’s instructions. A115.5 Separation of Occupancies. Occupancy separations shall be provided as specified in the California Building Code. When approved by the Building Official, existing wood lath and plaster in good condition or ½ inch gypsum wallboard may be acceptable where one-hour occupancy separations are required. Upon inspection, where it is found that the original construction or due to deterioration, a condition exists where fire could spread unchecked vertically or horizontally, provide a one-hour fire separation or repair the penetration to the satisfaction of the Fire Department and the Building and Safety Department. A115.6 Compliance Data. After notification by the Torrance Fire Department or Building and Safety Department, the owner shall, subject to the following time limits, take necessary actions to comply with the provisions of this chapter. Plans and specifications for the necessary alterations shall be filed with the Building Official within 18 months after the date of owner notification. Work on the required alterations to the building shall commence within 30 months of the date of owner notification and such work shall be completed within five years from the date of owner notification. The Fire Chief may grant necessary extensions of time when it can be shown that the specified time periods are not physically practical or pose an undue hardship. The granting of an extension of time for compliance shall be based upon the showing of good cause and subject to the filing of an acceptable systematic progressive plan of correction with the Building Official.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.