§ 85.2.080 — Fire protection systems. [Climatic, Topographical, Geological]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 85.2.080
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/c276fdee-2e46-45f3-ad3d-052ad9a76d07
§ 85.2.080: Fire protection systems. [Climatic, Topographical, Geological]
Chapter 9, Sections 901 and 903, of the California Fire Code 2022 Edition shall be amended to read in its entirety as follows: 901.11 Problematic Systems. In the event of a failure of a fire-protection system with 2 or more alarms in a 2 week period of accidental activations where there is no evidence of a situation requiring a response, the Fire Chief is authorized to require the building owner or occupant to provide fire watch personnel until the system is repaired. 901.12 Firewatch. Per Section 901.11 the Fire Chief is authorized to require the building owner or occupant to provide a fire watch with personnel acceptable to the Fire Chief until documentation is provided that the system is repaired and is operational. Such individuals shall be provided with at least one approved means for notification of the fire department and their only duty shall be to perform constant patrols of the protected premises, keep and maintain a log and keep watch for fires. 903.1.12 Total Coverage Fire Sprinkler Systems. Partially Sprinklered Buildings are prohibited. Existing partially sprinklered structures shall provide sprinkler coverage in unprotected areas when vacant and/or under tenant improvements. 903.2 Where Required. Section 903.2 An approved automatic sprinkler systems in new buildings and structures shall be required for all occupancies. Existing structures with change of occupancy will utilize Section 903 to determine required automatic sprinkler system coverage. Exception: New detached buildings under 1,000 square feet in size subject to approval of the Fire Code Official. 903.2.8.1.1 Existing R-3 Occupancies. An automatic sprinkler system must be provided throughout every existing R-3 occupancy when a 1,000 square foot or greater addition occurs established by the Building Code Official. 903.3.1.3.1 Protection of Attached Garages. Residential occupancies protected by an automatic sprinkler system in accordance with NFPA 13R or 13D must have automatic sprinklers installed in attached garages and in other areas as required by the Torrance Fire Department. 903.3.5.3 Hydraulically Calculated Systems. The design of hydraulically calculated fire sprinkler systems shall not exceed 90% of the water supply capacity. 903.3.8 Limited Area Sprinkler Systems. Partially Sprinklered Buildings are prohibited. Fire sprinkler coverage shall be throughout the entire structure. Exception: Protection for specific appliances and/or hazards. 903.3.8.1 through 903.3.8.5 are intentionally deleted. 903.3.10 Floor Control Valves. Floor control valves and waterflow detection assemblies shall be installed at each floor where any of the following occur: 1. | Buildings where the floor level of the highest story is located more than 30 feet above the lowest level of fire department vehicle access. 2. | Buildings that are three or more stories in height. 3. | Buildings that are two or more stories below the highest level of fire department access. 903.4.3 Alarms. One exterior approved audible and visible device, located on the exterior of the building in an approved location, shall be connected to each automatic sprinkler system. Such sprinkler water-flow alarm device shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. Exterior audible and visible alarm notification shall be provided on NFPA 13, NFPA 13R and NFPA 13D systems. Exception: Group R-3 and R3.1 occupancies floor control valves and waterflow detection assemblies shall not be required.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.