§ 85.2.180 — Appendix D - Fire Apparatus Access Roads. [Geological, Topographical]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 85.2.180
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/e67f8355-6feb-4560-a075-ad4f58da8cc4
§ 85.2.180: Appendix D - Fire Apparatus Access Roads. [Geological, Topographical]
Appendix D of the California Fire Code is amended to read in its entirety as follows: Appendix D Fire Apparatus Access Roads D101 - GENERAL D101.1 Scope. The provisions of Chapter 5, Section 503, apply unless specially modified by this appendix. This appendix is intended to provide guidelines to be considered by the Fire Chief when determining fire department access for commercial and residential developments when onsite access is required. Approved alternatives for fire department access include the needs of the local fire department and the following sections. Section D10 - Minimum Specifications D102.1 Access and Loading. Access roadways or streets shall comply with the provisions of Chapter 5, Section 503.2.1. Fire department access shall have an unobstructed width of not less than 25 feet. Road widths shall be as approved by the Fire Chief, or as follows: • | 20' feet wide for fire access only, • | 25' feet wide when public access, • | 30' feet wide for Aerial Ladder Truck Access • | (Measured curb to curb) D102.2 Surface. Fire apparatus access roads shall be designed and maintained to ensure that allweather driving capabilities are maintained in accordance with CFC Section 503.2.3. When required by the Fire Chief, proposed alternate design criteria for an "all-weather-surface" fire department access road or street, bearing the stamp of a professional engineer shall be provided. D103.2 Grades. Fire apparatus roads shall not exceed 8 percent in grade. Exceptions: 1. | The Fire Chief is authorized to allow increased steepness of grade, depending on the apparatus requirements of the fire department, when every building in the residential development is provided with an approved automatic fire sprinkler system. 2. | The Fire Chief may allow an increase of the maximum grade when other approved fire protection measures are provided. D103.4 Dead Ends. Dead end fire department access road shall be in accordance with Torrance Fire Department Operations Manual "Fire Lanes." For the purpose of the apparatus maneuvering, the use of bulb or cul-de-sacs, hammerheads, "Y"-heads, or other methods shall be subject to the capabilities of the fire apparatus, as required by the Fire Chief. D103.4.1 Cul-de-sacs. Cul-de-sacs shall maintain clear and unobstructed, allowing a turning radius that is consistent with the capabilities of the fire apparatus of the fire department, subject to the approval by the Fire Chief. Exception: When alternate methods and means relating turning around of fire apparatus are provided, the provisions of this section may be modified by the Fire Chief. D103.5.1 Access-control Devices. When required fire department access is restricted by the installation of access-control devices, such devices shall be approved by the Fire Chief, provide adequate clear width for fire department apparatus and be maintained operable at all times. D103.6 Signs. When motor vehicle parking is allowed on access roadways, such parking shall not encroach into the fire department access roadway. When this provision is compromised or restricted, the Fire Chief is authorized to require signage to indicate parking restriction in accordance with Section 503.3. D103.6.4 Drainage. When subject to run-off damage, the fire Chief is authorized to require approved drainage. D104.3 Multiple Access Provisions. The Fire Chief is authorized to require two or more means of access in accordance with Section 503.1.2. D105 Aerial Ladder Access. When the height of a structure at the roof eaves exceeds 27 feet or the capability of the fire department to access the roof safely utilizing ground ladders, the location and width of access roadways shall be such that truck mounted aerial ladders may be utilized. Aerial ladder access shall include the ability to maneuver apparatus, deploy outriggers and provide proper climbing angles. The minimum road width shall not be less than 30 feet, or as approved by the Fire Chief.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.
