§ 13.32.160 — Special restrictions—Grease interceptors

Code of Ordinances, City of Upland, California (eCode360 UP5026 version 2025-09-22: Includes legislation through Ord. No. 2002 adopted September 22, 2025) · Upland Municipal Code § 13.32.160

Corpus is an independent public-information project, not the official City of Upland website. Stable reference: corpuslaw.us/code/e59685b4-5511-403f-93f9-24cd4ddb57ee

§ 13.32.160: Special restrictions—Grease interceptors.

A. Any type of business such as, but not limited to, restaurants, bakeries, donut shops, drive-in eating establishments, ice cream or milk stations or drive-ins, hospitals, hotels, markets, etc., where any grease or other objectionable materials may be discharged into a public or private sewage main or disposal system shall have a grease and oil interceptor. All existing, businesses, as noted above, shall, after notification of waste that would require an interceptor, install a grease and oil interceptor within 180 days. Failure to comply with this section shall result in revocation of the nondomestic wastewater permit. B. Any newly built industrial or commercial building shall be exterior plumbed to allow for the addition of a grease and oil interceptor at a later date should the building be adapted for uses listed in subsection A of this section. C. Interceptors shall be constructed in accordance with the design approved by the chief building official. D. Each grease and oil interceptor shall be so installed and connected that it shall be at all times easily accessible for inspection, cleaning and removal of the intercepted grease. Such an interceptor shall not be installed in any part of a building where food is handled. Proper location of the grease and oil interceptor shall meet the approval of the chief building official. E. Each business establishment for which a grease and oil interceptor is required shall have an interceptor which shall serve only that business establishment. F. Buildings remodeled for a use requiring an interceptor shall be subject to the regulations contained in this section of the code. G. Waste discharge from fixtures and equipment in the establishments listed in subsection A of this section, which may contain grease or other objectionable materials, including, but not limited to, scullery sinks, pot and pan sinks, dishwashers, food disposals, soup kettles, etc., and floor drains located in areas where such objectionable materials may exist, shall be drained into the community sewer system through the interceptor. H. Interceptors shall be maintained in efficient operating condition by periodic removal of the accumulated grease. No such collected grease shall be introduced into any drainage piping or public or private sewer system. I. The cover for grease interceptors shall be one-half-inch steel plate reinforced as required by the chief building official, such reinforcing to depend upon the load to be imposed on the plate. The cover shall be watertight. J. Interceptors shall be installed in such a manner that precludes draining from areas outside the area intended to be served. K. At such time city work crews are called upon to clean a sewer line due to excessive accumulation of grease, the business establishment causing or contributing to the grease problem shall be fined $250.00 for each occurrence. In instances where the cleaning takes more than two hours, the business establishment shall be billed additional costs based on time and materials in excess of the two hours. L. Abandoned grease interceptors shall be pumped and filled as required for abandoned septic tanks in Section 1119 of the Uniform Plumbing Code.

( Prior code § 5860.5 )

Ask a question about Upland law

Corpus searches the Upland sections it holds and shows the ones that match, with their citations. Free, no sign-in.