For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-173 — IRC - Section R109.1.2, Plumbing, mechanical, gas, and electrical systems inspection

Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 18-173

Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/35ca32f7-fa4a-470e-b369-38ce18ff39b1

Sec. 18-173. - IRC - Section R109.1.2, Plumbing, mechanical, gas, and electrical systems inspection.

Section R109.1.2. Plumbing, mechanical, gas and electrical systems inspection, is hereby amended h in its entirety to read as follows: "R109.1.2. Plumbing, mechanical, gas and electrical systems inspection. A rough mechanical, electrical, and plumbing inspection shall be made prior to rough frame inspection and after the roof and roof covering, framing, fire-blocking, and bracing are in place, and all vents, duct systems, piping, and HVAC equipment is properly installed, including all vents, exhausts, and intakes extended through the completed roof and walls. Exception: Backfiling of ground-source heat pump loop systems tested in accordance with Section M.2105.28 prior to inspection shall be permitted.".

(Ord. No. 4921, § 7, 3-24-2026)

Ask a question about Arvada law

Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.