§ 18-185 — IRC - Section R408.8, Under-floor vapor retarder
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 18-185
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/34c5855a-23f8-4cf3-bc45-f290d29537c8
Sec. 18-185. - IRC - Section R408.8, Under-floor vapor retarder.
Section 408.8. Under-floor vapor retarder, is hereby amended by adding a second paragraph to read as follows: "The vapor retarder class shall be defined using the desiccant method with Procedure A of ASTM E96. The following shall be deemed to meet the class specified: • Class I: Rated at 0.1 perms or less (min. 6 mil thickness). Sheet polyethylene (visqueen), unperforated aluminum foil (FSK). • Class II: Rated greater than 0.1 perms and less than or equal to 1.0 perms. Kraft-faced fiberglass batts. • Class III: Rated greater than 1.0 perms and less than or equal to 10 perms. Latex or enamel paint."
(Ord. No. 4921, § 7, 3-24-2026)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.
