Sec. 18-185. - IRC - Section R408.8, Under-floor vapor retarder.

Section 408.8. Under-floor vapor retarder, is hereby amended by adding a second paragraph to read as follows: "The vapor retarder class shall be defined using the desiccant method with Procedure A of ASTM E96. The following shall be deemed to meet the class specified: • Class I: Rated at 0.1 perms or less (min. 6 mil thickness). Sheet polyethylene (visqueen), unperforated aluminum foil (FSK). • Class II: Rated greater than 0.1 perms and less than or equal to 1.0 perms. Kraft-faced fiberglass batts. • Class III: Rated greater than 1.0 perms and less than or equal to 10 perms. Latex or enamel paint."

(Ord. No. 4921, § 7, 3-24-2026)