§ 18-188 — IRC - Section R501.3.2, Grading under structural floors
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 18-188
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/a43b8d91-30d8-4714-a711-08e7ca52021a
Sec. 18-188. - IRC - Section R501.3.2, Grading under structural floors.
Section R501.3.2. Grading under structural floors, is hereby added to read as follows: "R501.3.2. Grading under structural floors. When structural basement floors are installed, a minimum of 18 inches (457 mm) of clear space is required below untreated wood floor joists and any wood girders or beams. Where steel or concrete beams or joists are used, the minimum clearance shall be the height of the void plus 6 inches (152 mm), or be as recommended by the soils engineer. The surface of the underfloor area shall be free of construction debris and graded to a relatively flat plane to slope toward the sump pit, or toward drain systems installed to control free water in the underfloor space. The underfloor area shall not allow ponding of water."
(Ord. No. 4921, § 7, 3-24-2026)
Ask a question about Arvada law