Sec. 22-312. - Section 305.4 amended; freezing.

Sec. 305.4 of the plumbing code is amended to read as follows: 305.4 Freezing. Water, soil and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperature unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply system piping shall be installed not less than 12 inches (305 mm) below the frost line and not less than 12 inches (305 mm) below grade.

(Code 1994, § 16.28.070; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016)