§ 22-321 — Table 906.1 amended; size and developed length of stack vents and vent stacks
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 22-321
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/a7e0eb90-0265-4d33-a0a3-a4a0406ae0d2
Sec. 22-321. - Table 906.1 amended; size and developed length of stack vents and vent stacks.
Table 906.1 of the plumbing code shall be amended to read as follows: Table 906.1. Maximum Unit Loading and Maximum Length of Drainage and Vent Piping Size of Pipe, inches (mm) | 1¼ (32) | 1½ (40) | 2 (50) | 2½ (65) | 3 (80) | 4 (100) | 5 (125) | 6 (150) | 8 (200) | 10 (250) | 12 (300) Maximum Units Drainage piping 1 Vertical | 1 | 2 2 | 16 3 | 32 3 | 48 4 | 256 | 600 | 1,380 | 3,600 | 5,600 | 8,400 Horizontal | 1 | 1 | 8 3 | 14 3 | 35 4 | 216 5 | 428 5 | 720 5 | 2,640 5 | 4,680 5 | 8,200 5 Maximum Length Drainage piping Vertical, feet | 45 | 65 | 85 | 148 | 212 | 300 | 390 | 510 | 750 | — | — (m) | (14) | (20) | (26) | (45) | (65) | (91) | (119) | (155) | (228) | — | — Horizontal (unlimited) Vent piping (See note) Horizontal and vertical Maximum units | 1 | 8 3 | 24 | 48 | 84 | 256 | 600 | 1,380 | 3,600 | — | — Maximum lengths, feet | 45 | 60 | 120 | 180 | 212 | 300 | 390 | 510 | 750 | — | — (m) | (14) | (18) | (37) | (55) | (65) | (91) | (119) | (155) | (228) | — | — 1 Excluding trap arm. 2 Except sinks, urinals and dishwashers. 3 Except six-unit traps or water closets. 4 Only four water closets or six-unit traps allowed on any vertical pipe or stack; and not to exceed three water closets or six-unit traps on any horizontal branch or drain. 5 Based on one-quarter inch per foot (20.9 mm/m) slope. For one-eighth inch per foot (10.4 mm/m) slope, multiply horizontal fixture units by a factor of 0.8. Note: The diameter of an individual vent shall not be less than 1¼ inches (31.8 mm) nor less than one-half the diameter of the drain to which it is connected. Fixture unit load values for drainage and vent piping shall be computed from Table P3004.1. Not to exceed one-third of the total permitted length of any vent may be installed in a horizontal position. When vents are increased one pipe size for their entire length, the maximum length limitations specified in this table do not apply. _____
(Code 1994, § 16.28.160; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.