§ 22-326 — Section 1003.3.4.1 amended; grease interceptor capacity
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 22-326
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/82b7872c-1bb3-4b37-84ab-d5b33fc253a9
Sec. 22-326. - Section 1003.3.4.1 amended; grease interceptor capacity.
Sec. 1003.3.4.1 of the plumbing code shall be amended to read as follows: 1003.3.4.1 Grease interceptor capacity. Grease interceptors shall be sized as per Table 1003.3.4.1. Table 1003.3.4.1. Grease Interceptor Sizing Num- ber of meals per peak hour | X | Waste flow rate | X | Reten- tion time | X | Stor- age factor | = | Inter- ceptor size (liquid capacity) a. Meals served at peak hour. b. Waste flow rate. 1. With dishwashing machine: six-gallon (22.7 L) flow. 2. Without dishwashing machine: five-gallon (18.9 L) flow. 3. Single service kitchen: two-gallon (7.6 L) flow. 4. Food waste dispenser: one-gallon (3.8 L) flow. c. Retention time. Commercial kitchen waste. Dishwasher: 2.5 hours. Single service kitchen. Single serving: 1.5 hours. d. Storage factors. Fully equipped commercial kitchen: 1. 8-hour operation: 1. 2. 16-hour operation: 2. 3. 24-hour operation: 3. 4. Single service kitchen: 1.5.
(Code 1994, § 16.28.210; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016)
Ask a question about Greeley law