Sec. 22-319. - Section 712.4.2 amended; capacity.
Sec. 712.4.2 of the plumbing code is amended to read as follows: 712.4.2 Capacity. A sewage pump or sewage ejector shall have the capacity and head for the application requirements. Pumps or ejectors that receive the discharge of water closets shall be capable of handling spherical solids with a diameter of up to and including two inches (51 mm). Other pumps or ejectors shall be capable of handling spherical solids with a diameter of up to and including one inch (25.4 mm). The minimum capacity of a pump or ejector based on the diameter of the discharge pipe shall be in accordance with Table 712.4.2. Exceptions: Grinder pumps or grinder ejectors that receive the discharge of water closets shall have a minimum discharge opening of two inches (51 mm).