§ 22-382 — Article 210.11(C)(3) amended; bathroom branch circuits

Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 22-382

Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/e199b4a2-9354-4178-972f-bfd11886d159

Sec. 22-382. - Article 210.11(C)(3) amended; bathroom branch circuits.

Article 210.11(C)(3) of the NEC © , adopted at section 22-377, is amended to read as follows: 210.11(C)(3) Bathroom Branch Circuits. In addition to the number of branch circuits required by other parts of this section, at least one 120-volt, 20-ampere branch circuit shall be provided to supply bathroom receptacle outlet. Such circuits shall have no other outlets. Exception: Where the 20-ampere circuit supplies a single bathroom, outlets for other equipment within the same bathroom shall be permitted to be supplied in accordance with 210.23(A)(1) and (A)(2). A minimum of one lighting outlet (not required by this code to be GFCI protected) shall be connected so as not to be protected by the GFCI personnel protection.

(Code 1994, § 16.32.060; Ord. No. 13, 2015, § 2, 6-2-2015)