§ 16.04.360 — Section 1010.2.12 amended; delayed egress
Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 16.04.360
Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/e5d8cf46-f71d-4251-8aa6-70f2a20b7b4f
Sec. 16.04.360. - Section 1010.2.12 amended; delayed egress.
Section 1010.2.12 of the International Building Code is deleted in its entirety and replaced with the following: 1010.2.12: Delayed egress. Approved, listed, delayed egress locking systems shall be permitted to be installed on doors serving any occupancy except Group A, E, and H occupancies in buildings which are equipped throughout with an automatic sprinkler system in accordance with section 903.3.1.1, and an approved automatic smoke detection system installed in accordance with section 907.
(Ord. No. O-2026-23, § 1, 6-9-2026)