8.36.110 - Construction requirements for underground tanks.
Underground tanks shall conform to the following requirements: A. Material—Thickness. Tanks shall be constructed of open hearth steel or of wrought iron of a thickness not less than that specified in the following table. For liquids heavier than thirty-five degrees Baume, tanks may be constructed of concrete in accordance with the regulations of the National Fire Protection Association. Minimum Thickness of Material Capacity (gallons) | Gauge (U.S. Standard) | Lbs. per Sq. Ft. 1 to 285 ..... | 16 | 2.50 286 to 560 ..... | 14 | 3.125 561 to 1,100 ..... | 12 | 4.375 1,101 to 4,000 ..... | 7 | 7.50 4,001 to 12,000 ..... | ¼ inch | 10.00 12,001 to 20,000 ..... | 5/16 inch | 12.50 20,001 to 30,000 ..... | ⅜ inch | 15.00 For tanks of one thousand one hundred (1,100) gallons and more a tolerance of ten percent in capacity shall be allowed. B. Quality of Material, etc. No seconds shall be used in the construction of any tank. All material lighter than No. 7 U.S. standard gauge shall be galvanized. For class III liquids, if adequate inner bracing is provided, tanks from twelve thousand one (12,001) to thirty thousand (30,000) gallons capacity may be built of one-fourth-inch steel plate. C. Joints—Strength. All joints of tanks shall be riveted and caulked, brazed, welded or made tight by some equally satisfactory process. Tanks shall be tight and sufficiently strong to bear without injury the most severe strains to which they may be subjected in use. Shells of tanks shall be properly reinforced where connections are made, and all connections made through the top of the tank shall be above the liquid level. Tanks for systems under pressure shall be designed for four times the maximum working pressure and tested to twice the maximum working pressure. D. Coating for Iron, Steel Tanks. All iron or steel tanks shall be thoroughly coated on the outside with tar, asphaltum or other suitable rust-resisting material. Where soil contains corrosive substances, such special protection shall be provided as may be required by the fire chief. E. Use of Copper, etc. With the approval of the fire chief, tanks of copper or other suitable material may be used if, after the necessary handling incident to installation, they are equivalent in strength, rigidity, durability and tightness to the steel or iron tanks described in this chapter.
(Ord. dated 12/21/92 § 75(b); prior code § 11-66)
Ask a question about Bridgeport law
Corpus searches the Bridgeport sections it holds and shows the ones that match, with their citations. Free, no sign-in.