8.36.130 - Construction requirements for aboveground tanks.

Aboveground tanks shall conform to the following requirements: A. Tanks shall be riveted, welded or brazed, and shall be soldered, caulked or otherwise made tight in a mechanical and workmanlike manner. if any tank is to be used with a pressure discharge system, it shall safely sustain a hydrostatic test at least double the pressure to which it may be subjected. Except as provided in this chapter, tanks shall be constructed entirely of metal, including the top, sides and bottom thereof. All openings shall be gastight, except breather vents, which shall be screened as provided in Section 8.36.090. All pipe connections shall be made through flanges or metal reinforcements securely riveted, welded or bolted to the tank and shall be made thoroughly tight. B. Roofs and tops of tanks shall have no unprotected openings. Roofs and tops shall be securely fastened to the top ring of the tank with joints of the same tightness as the joints between the rings, such joints to be riveted and caulked, brazed, welded or made tight by other process satisfactory to the fire chief. C. With the approval of the fire chief, tanks of copper or other suitable material may be used if, after the necessary handling incident to the installation, they are equivalent in strength, rigidity, durability and tightness to the steel or iron tanks described in this chapter. For liquids of thirty-five (35) degrees Baume or heavier, tanks may be constructed of concrete in accordance with the regulations of the National Fire Protection Association. D. All iron and steel tanks shall be thoroughly coated on the outside with tar, asphaltum or other rust-resisting paint or coating. E. Except in oil refineries or large water terminals, tanks containing flammable liquids having a flash point below seventy (70) degrees Fahrenheit closed cup tester shall have painted conspicuously upon the side the wording, "FLAMMABLE—KEEP FIRE AWAY." F. All tanks shall be electrically grounded by resting directly on moist earth or otherwise electrically grounded to permanent moisture to the satisfaction of the fire chief. No insulated connections shall be permitted. Telephone poles or other projections liable to act as lighting discharge points shall be kept as far as practicable from tanks. All steel work or reinforced concrete tanks shall be interconnected and grounded by an approved method. G. Tanks more than one foot above the ground shall have foundation and supports of noncombustible materials, except that wooden cushions may be permitted. No combustible material shall be permitted under or within ten feet of any aboveground outside storage tanks.

(Ord. dated 12/21/92 § 75(b); prior code § 11-68)

Ask a question about Bridgeport law

Corpus searches the Bridgeport sections it holds and shows the ones that match, with their citations. Free, no sign-in.