8.36.120 - Thickness of material in aboveground tanks.

Aboveground tanks (including tops) shall be constructed throughout of open hearth steel or of wrought iron of a thickness in accordance with the following requirements: no open tanks shall be used; for liquids of thirty-five (35) degrees Baume or heavier, tanks may be constructed of concrete in accordance with the regulations of the National Fire Protection Association. A. Horizontal or vertical tanks not over one thousand one hundred (1,100) gallons capacity shall conform to the following table: Capacity (gallons) | Minimum Thickness of Material (U.S. Standard) 1 to 60 ..... | 18 gauge 61 to 350 ..... | 16 gauge 351 to 560 ..... | 14 gauge 561 to 1,100 ..... | 12 gauge. B. Horizonal Tanks Over One Thousand One Hundred (1,100) Gallons Capacity. Tanks having a diameter of not over six feet shall be made of at least three-sixteenths-inch steel. Tanks having a diameter of over six feet and less than eleven and one-half feet shall be made of at least one-fourth-inch steel. C. Vertical Tanks Over One Thousand One Hundred (1,100) Gallons Capacity. Tanks of this class shall be of such material and so constructed as to have a factor of safety of at least 2.5. The minimum thickness of the shell or bottom shall be three-sixteenths inch. The minimum thickness of the roof shall be one-eighth inch. The thickness of the plates shall be in accordance with the following formula: T - 2.604 × H × D × F × S / t × E Where, T = thickness of plate in inches H = height of tank in feet above the bottom of the ring under consideration D = diameter of the tank in feet F = factor of safety (taken as 2.5) S = specific gravity of liquid stored (water = 1) t = tensile strength of plate in pounds per square inch E = efficiency of vertical joint in ring under consideration The tensile strength of the steel shall be taken as fifty-five thousand (55,000) pounds per square inch, and the shearing strength of rivets shall be taken as forty thousand (40,000) pounds per square inch.

(Prior code § 11-67)

Ask a question about Bridgeport law

Corpus searches the Bridgeport sections it holds and shows the ones that match, with their citations. Free, no sign-in.