§ 13-809 — Flammable finishes
Code of Ordinances of the City of New Haven, Connecticut (Supp. No. 31: codified through Ordinance No. 2025-0018, enacted September 11, 2025) · New Haven Code of Ordinances § 13-809
Corpus is an independent public-information project, not the official City of New Haven website. Stable reference: corpuslaw.us/code/31e462b5-fdd4-444e-aa23-c89cd1fe684d
Sec. 13-809. - Flammable finishes.
(1) General. This article shall apply to locations or areas where the following activities are regularly done: (1) the application of flammable or combustible paint, varnish, lacquer, stain or other flammable or combustible liquid applied as a spray by whatever means, in continuous or intermittent processes; and (2) dip tank operations in which articles or materials are passed through contents of tanks, vats or containers of flammable or combustible liquids, including coating, finishing, treating and similar processes. (2) Permit required. No person shall conduct spraying or dipping operations utilizing more than one gallon of flammable or combustible liquids per working day unless he holds a permit. (3) Smoking prohibited. Smoking shall be prohibited in any spray finishing areas and in the vicinity of dip tanks. "No Smoking" signs with lettering of approved size shall be conspicuously posted in such areas and shall read, "By Order of the Fire Marshal". (4) Welding warning signs. Conspicuous signs shall be posted in the vicinity of all spraying areas, dipping operations and paint storage rooms, conveying the following warning: NO WELDING The use of welding or cutting equipment in, or near this area is dangerous because of fire and explosion. Welding and cutting shall be done only under the supervision of the foreman in charge. (5) Electric wiring and equipment. No person shall permit any flammable finishing operation to be conducted in any structures unless electric wiring and equipment shall conform to the provisions of this article and shall otherwise be installed in accordance with nationally recognized safe practice. (6) Location of spray finishing operations. No person shall permit spray finishing operations to be conducted in buildings used for assembly, educational, institutional or residential occupancies, except in a room designed for the purpose, protected with an approved system of automatic sprinklers and separated vertically and horizontally from other areas by construction having not less than two (2) hours fire resistance rating. (7) Spray booths. No person shall permit spraying of flammable finishes to be conducted in spray booths which violate the following: (a) Spray booths shall be substantially constructed of noncombustible material. (b) The interior surfaces of spray booths shall be smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury. (c) The floor of the spray booth and operators' working area, if combustible, shall be covered with noncombustible, nonsparking material of such character as to facilitate the safe cleaning and removal of residues. (d) If installed, baffle plates shall be of noncombustible material, readily removable or accessible on both sides for cleaning, and designed to promote an even flow of air through the booth and to prevent the deposit of over-spray before it enters the exhaust duct. Such baffle plates shall not be located in exhaust ducts. (e) Each spray booth having a frontal area larger than nine square feet shall have a metal deflector or curtain not less than two and one-half inches (2½") deep installed at the upper outer edge of the booth, over the opening. (f) Each spray booth shall be separated from other operations by not less than three feet, or by a greater distance, or by such partition or wall as the fire marshal may require to reduce the danger from juxtaposition of hazardous operations. (g) Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than three feet on all sides shall be kept free from storage or combustible construction. (h) When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination. (8) Dry type overspray collectors (exhaust air filters). No person shall install or permit overspray dry filters or filter rolls to be installed in conventional dry type spray booths unless in conformance with the following: (a) The spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross-section during spraying operations) shall be not less than one hundred (100) linear feet per minute. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. (b) All discarded filter pads and filer rolls shall be immediately removed to a safe, well detached location or placed in a water-filled metal container and disposed of at the close of the day's operation unless maintained completely in water. (c) The location of filters in a spray booth shall be so as to not reduce the effective booth enclosure of the articles being sprayed. (d) Space within spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers. (e) Filters or filter rolls shall not be used when applying a spray material known to be highly susceptible to spontaneous heating and ignition. (f) Clean filters or filter rolls shall be noncombustible or of approved type. (g) Filters and filter rolls shall not alternately be used for different types of coating materials, where the combination of materials may be conducive to spontaneous ignition. (9) Electrical and other sources of ignition. No person shall spray or permit any flammable finish to be sprayed in any structure which does not comply with the following: (a) There shall be no open flame or spark producing equipment in any spraying area as defined in this code, nor within twenty feet (20') thereof, unless separated by a partition, except as permitted in section 13-809(14), Drying Apparatus, and in sections 13-809(26) to 13-809(29), Electrostatic Apparatus. (b) Room heating appliances, steam pipes or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate. (c) Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices or terminal connections and except as hereinafter provided in sections 13-809(14)(c) relating to drying apparatus and 13-809(26) to 13-809(29) relating to electrostatic apparatus. (d) Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area shall be of explosion-proof type approved for use in such hazardous locations. (e) Electrical wiring, motors, and other equipment outside of but within twenty feet (20') of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions. Such area shall be considered a Class I, Division 2 hazardous location under the National Electrical Code. (f) Electric lamps outside of but within twenty feet (20') of any spraying area and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from physical damage by suitable guards or by location. (g) Portable electric lamps shall not be used in any spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, shall be of the type approved for hazardous locations. (h) All metal parts of spray booths, exhaust ducts and piping systems conveying flammable liquids shall be properly electrically grounded in an effective and permanent manner. (10) Ventilation of spray booths and spray finishing areas. No person shall spray or permit any flammable liquid to be sprayed in any structure which does not comply with the following: (a) All spraying areas shall be provided with mechanical ventilation adequate to prevent the dangerous accumulation of vapors and to safely remove such vapors to a safe location. (b) Mechanical ventilation shall be kept in operation at all times while spraying operations are being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted. (c) Each spray booth shall have an independent exhaust duct system discharging to building exterior, except multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than eighteen square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without operating all. (d) Electric motors driving exhaust fans shall not be placed inside booths or ducts. Fan rotating element shall be nonferrous or nonsparking or the casing shall consist of or be lined with such material. (e) Belts shall not enter duct or booth unless belt and pulley within the duct or booth are tightly enclosed. (f) Exhaust ducts shall be constructed of steel and shall be substantially supported. (g) Exhaust ducts shall have a clearance from unprotected combustible construction or material of not less than 18 inches. If combustible construction is provided with the following protection applied to all surfaces within eighteen inches (18"), clearances may be reduced to the distances indicated. (1) 28 gauge sheet metal on ¼-inch asbestos mill board .....12 inches (2) 28 gauge sheet metal on ⅛ inch asbestos mill board spaced out one inch on noncombustible spacers .....9 inches (3) 22 gauge sheet metal on 1 inch rockwool bats reinforced with wire mesh or the equivalent. ..... (h) Air exhausted from spraying operations shall not be recirculated. (11) Storage and handling of flammable liquids. No person shall store, handle or permit flammable liquids to be stored or handled in violation of the following: (a) The storage and handling of flammable liquids shall be in accordance with article 16 and shall also conform to the provisions of this section. (b) Where the quantity of liquid in five-gallon (5 gal.) and smaller containers, other than original sealed containers, exceeds a total of ten gallons (10 gals.) it shall be stored in a storage cabinet conforming to section 13-810(1) or in storage or mixing rooms conforming to sections 16.32 or 16.72 (b) and (c). (c) Original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping shall be used for bringing flammable liquids into spray finishing areas. Open or glass containers shall not be used. (d) Containers supplying spray nozzles shall be of closed type or provided with metal covers kept closed. Containers not resting on floors shall be on noncombustible supports or suspended by wire cables. Containers supplying spray nozzles by gravity flow shall not exceed ten gallons (10 gals.) capacity. (e) All containers or piping to which is attached a hose or flexible connection shall be provided with a shut-off valve at the connection. Such valves shall be kept shut when not in use. (f) Heaters shall not be located in spray booths or other locations subject to the accumulation of deposits or combustible residue. (g) If flammable liquids are supplied to spray nozzles by positive displacement pumps, pump discharge line shall be provided with an approved relief valve discharging to pump suction or to a safe detached location, or a device shall be provided to stop the prime mover when the discharge pressure exceeds one hundred twenty-five (125) percent of the normal operating pressure. (h) Whenever flammable liquids are transferred from one container to another, both containers shall be bonded or effectively grounded. Piping systems for flammable liquids shall be permanently grounded. (12) Fire protection equipment. Suitable portable fire extinguishers, small hose or other fire extinguishing equipment installed near all spraying areas as specified by the fire marshal. (13) Operations and maintenance. No person shall spray with flammable liquids or permit flammable liquids to be sprayed in violation of the following: (a) All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. (b) Scrapers, spuds or other such tools used for cleaning purposes shall be of nonsparking material. (c) Residue scrapings and debris contaminated with residue shall be immediately removed from premises and properly disposed of. (d) The use of flammable solvents for cleaning operations shall be restricted to those having flash points not less than kerosene except solvents with flash points not less than those normally used in spraying operations may be used for cleaning spray nozzles and auxiliary equipment, provided such cleaning is conducted inside spray booths and ventilating equipment is operating during cleaning. (e) Spray booths shall not be alternately used for different types of coating materials, where the combination of the materials may be conducive to spontaneous ignition, unless all deposits of the first used material are removed from the booth and exhaust ducts prior to spraying with the second. (f) Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily and at the end of each shift. (14) Drying apparatus. No person shall use or permit any apparatus for the drying of flammable liquids be used which does not comply with the following: (A) Drying apparatus shall, in addition to conforming with the requirements of this article, comply with the applicable provisions of subsection (13) above. (B) Spraying booths, rooms or other enclosures used for spraying operations shall not alternately be used for the purpose of drying by any arrangement which will cause a material increase in the surface temperature of the spray booth, room, or enclosure. (C) Except as specifically provided in section 13-809(14) drying or baking units, utilizing a heating system having open flames or which may produce sparks, shall not be installed in a spraying area as defined herein, but may be installed adjacent thereto when equipped with an interlocked ventilating system arranged to: (1) Thoroughly ventilate the drying space before heating system can be started; (2) Maintain a safe atmosphere at any source of ignition; (3) Automatically shut down heating system in the event of failure of the ventilating system. (D) Automobile refinishing booths or enclosures, otherwise installed and maintained in conformity with this division, may alternately be used for drying with portable infra-red drying apparatus when conforming with the following: (1) The procedure shall be restricted to low-volume, occasional spray application. (2) Interior of spray enclosures shall be kept free of overspray deposits. (3) During spray operations, the drying apparatus and electrical connections and wiring thereto shall not be located within spray enclosure nor in any other location where spray residue may be deposited thereon. (4) Spraying apparatus, drying apparatus, and ventilating system of spray enclosure shall be equipped with suitable inter-locks so arranged that: (a) Spraying apparatus cannot be operated while drying apparatus is inside spray enclosure. (b) Spray enclosure will be purged of spray vapors for a period of not less than three (3) minutes before drying apparatus can be energized. (c) Ventilating system will maintain a safe atmosphere within the enclosure during the drying process and drying apparatus will automatically shut off in the event of failure of the ventilating system. (5) All electrical wiring and equipment of drying apparatus shall conform to the provisions of this article and shall otherwise be installed in accordance with nationally recognized safe practice. Only equipment of a type approved for Class I, Division 2 Hazardous Locations shall be located within eighteen inches (18") of floor level. All metallic parts of drying apparatus shall be properly electrically bonded and grounded. (15) Location of dip tank operations. No person shall conduct or permit to be conducted, dip tank operations in buildings used for assembly, educational, institutional or residential occupancies, except in a room designed for the purpose, protected with an approved system of automatic sprinklers and separated vertically and horizontally from other areas by construction having not less than two (2) hours fire resistance rating. (16) Ventilation of vapor areas. No person shall operate or permit any dip tanks to be operated in violation of the following: (a) All vapor areas shall be provided with mechanical ventilation adequate to prevent the dangerous accumulation of vapors and to remove such vapors to a safe location. (b) Required ventilating systems shall be so arranged that the failure of any ventilating fan shall automatically stop any dipping conveyor system. (17) Construction of dip tanks. No person shall install or permit dip tanks to be installed or constructed in violation of the following: (a) Dip tanks, including drain boards if provided, shall be constructed of substantial noncombustible material, and their supports shall be of heavy metal, reinforced concrete or masonry. (b) Dip tanks of over one hundred fifty (150) gallons in capacity or ten square feet (10 sq. ft.) in liquid surface area shall be equipped with a properly trapped overflow pipe leading to a safe location outside buildings. (c) The bottom of the overflow connection shall be not less than six inches (6") below the top of the tank. (d) Dip tanks over five hundred (500) gallons in liquid capacity shall be equipped with bottom drains automatically and manually arranged to quickly drain tank in event of fire, unless the viscosity of the liquid at normal atmospheric temperature makes this impractical. Manual operation shall be from a safely accessible location. Where gravity flow is not practicable, automatic pumps shall be provided. (e) Such drains shall be trapped and discharge to a closed properly vented salvage tank or to a safe outside location. (f) Dip tanks utilizing a conveyor system shall be so arranged that in the event of fire, the conveyor system shall automatically cease motion and required bottom drains shall open. (18) Electrical and other sources of ignition. No person shall operate or permit a dip tank to be operated in violation of the following: (a) There shall be no open flames, spark producing devices, or heated surfaces having a temperature sufficient to ignite vapors in any vapor area. (b) Electrical wiring and equipment in any vapor area shall be explosion-proof type approved for use in such hazardous locations. Such area shall be considered as Class I, Division 1 Hazardous Location under the National Electrical Code. (c) Unless specifically approved for locations containing both deposits of readily ignitable residues and explosive vapors, there shall be no electrical equipment in the vicinity of dip tanks or associated drain boards or drying operations which are subject to splashing or dripping of dip tank liquids, except wiring in rigid conduit or in threaded boxes or fittings containing no taps, splices or terminal connections and except as hereinafter specifically permitted in sections 13-809(22) to 13-809(28) relating to electrostatic apparatus. (d) In any floor space outside a vapor area, but within twenty feet (20') therefrom, and not separated by tight partitions, there shall be no open flames or spark producing devices, except drying and baking apparatus may be installed adjacent to vapor areas when conforming to section 13-809(14) (c). Such area shall be considered a Class I, Division 2 Hazardous Location under the National Electrical Code. (19) Operations and maintenance. No person shall operate or permit a dip tank to be operated in violation of the following: (a) Areas in vicinity of dip tanks shall be kept as clear of combustible stock as practical and shall be kept entirely free of combustible debris. (b) When waste or rags are used in connection with dipping operations, approved metal waste cans shall be provided and all impregnated rags or waste deposited therein immediately after use. The contents of waste cans shall be disposed of at the end of each shift by methods approved by the fire marshal. (20) Fire extinguishing equipment. (a) No person shall operate or permit a dip tank to be operated unless the areas in the vicinity of dip tanks shall be provided with manual fire extinguishers suitable for flammable liquid fires, as specified by the fire marshal. (b) Dip tanks of over one hundred fifty (150) gallons capacity or ten square feet (10 sq. ft.) liquid surface area shall be protected with at least one of the following automatic extinguishing facilities: (1) Approved automatic water spray extinguishing system; (2) Approved automatic foam extinguishing system; (3) Approved automatic carbon dioxide system. (4) Dip tank covers conforming to section 13-809(21). (c) Dip tanks containing a liquid with a flashpoint below 110°F. (when used in such manner that the liquid temperature may equal or be greater than its flashpoint from artificial or natural causes) shall conform to section 13-809(20) (b) when having both a capacity of more than ten (10) gallons and a liquid surface area of more than four square feet (4 sq. ft.). (21) Dip tank covers. No person shall operate or permit dip tanks to be operated unless: (a) Covers arranged to close automatically in event of fire shall be actuated by approved automatic devices and shall also be arranged for manual operation. (b) Covers shall be of substantial noncombustible material or of tin-clad type with enclosing metal applied with locked joints. (c) Chains or wire rope shall be used for cover support or operating mechanism where the burning of a cord would interfere with the action of the device. (d) Covers shall be kept closed when tanks are not in use. (22) Hardening and tempering tanks. No person shall operate or permit dip tanks to be operated unless: (a) Hardening and tempering tanks shall conform to sections 13-809(17), 13-809(18), 13-809(19), 13-809(20) (a), as well as to the following paragraphs of this section, but shall be exempt from other provisions of division III of this article. (b) Tanks shall be located as far as practicable from furnaces and shall not be located on or near combustible floors. (c) Tanks shall be provided with a noncombustible hood and vent or other equally effective means, venting to outside of building to serve as a vent in case of fire. All such vent ducts shall be treated as flues and be kept well away from combustible roofs or materials. (d) Tanks shall be equipped with a high temperature limit switch arranged to sound an alarm when the temperature of the quenching medium reaches 50° F. below the flash point. (e) Hardening and tempering tanks of over five hundred (500) gallons capacity or twenty-five square feet (25 sq. ft.) liquid surface area shall be protected as specified in section 13-809(20) (b). (f) Air under pressure shall not be used to fill or to agitate oil in tanks. (23) Flow coat operations. (a) No person shall carry on or permit flow coat operations which do not conform to the requirements for dip tanks, considering the area of the sump and any areas on which paint flows as the area of a dip tank. (b) No person shall carry on or permit flow coat operation unless paint shall be supplied by direct low pressure pumping arranged to automatically shut down by means of approved heat actuated devices, in case of fire, or by a gravity tank not exceeding ten (10) gallons in capacity. (24) Roll coating. (a) No person shall conduct the processes of roll coating, spreading and impregnating, in which fabrics, paper or other material is passed directly through a tank or through containing flammable liquids, or over the surface of a roller that revolves partially submerged in a flammable liquid shall conform to the requirements of this section and to the applicable provisions of this section 13-809. (b) No person shall conduct or permit roll coating operation to be conducted unless adequate arrangements shall be made to prevent sparks from static electricity by electrically bonding and grounding all metallic rotating and other parts of machinery and equipment and by the installation of static collectors or maintaining a conductive atmosphere by means such as high relative humidity. ELECTROSTATIC APPARATUS (25) Equipment type and location. (a) No person shall operate electrostatic apparatus and devices used in connection with paint spraying and paint detearing operations which are not of a type approved by the fire marshal. (b) No person shall operate or permit electrostatic apparatus to be operated unless transformers, power packs, control apparatus, and all other electrical portions of the equipment, with the exception of high voltage grids and electrostatic atomizing heads and their connections, shall be located outside of the spraying or vapor areas as defined herein or shall conform to the requirements of sections 13-809(9) or 13-809(18). (c) No person shall operate or permit electrostatic apparatus to be operated unless electrodes and electrostatic atomizing heads shall be of substantial construction, shall be rigidly supported in permanent locations and shall be effectively insulated from ground. Insulators shall be nonporous and noncombustible. (26) Controls. (a) No person shall operate or permit electrostatic apparatus to be operated unless a space shall be maintained between goods being painted or deteared and electrodes, electrostatic atomizing heads or conductors of at least twice the sparking distance. A suitable sign stating the sparking distance shall be conspicuously posted near the assembly. (b) Electrostatic apparatus shall be equipped with automatic controls which will operate without time delay to disconnect the power supply to the high voltage transformer and to signal the operator under any of the following conditions: (1) Stoppage of ventilating fans or failure of ventilating equipment from any cause. (2) Stoppage of the conveyor carrying goods past the high voltage grid. (3) Occurrence of a ground or of an imminent ground at any point on the high voltage system. (4) Reduction of clearance below that specified in section 15.42a. (27) Guards and signs. (a) No person shall operate or permit electrostatic apparatus to be operated unless adequate booths, fencing, railings or guards shall be so placed about the equipment that they, either by their location or character or both, assure that a safe isolation of the process is maintained from plant storage or personnel. Such railings, fencing and guards shall be of conducting material, adequately grounded, and shall be at least five feet (5') from processing equipment. (b) Signs designating the process zone as dangerous as regards fire and accident shall be posted. (28) Maintenance. No person shall operate or permit electrostatic apparatus to be operated unless: (a) All insulators shall be kept clean and dry. (b) Drip plates and screens subject to paint deposits shall be removable and shall be taken to a safe place for cleaning. AUTOMOBILE UNDERCOATING (29) Operations included. (a) Automobile undercoating spray operations, conducted in areas having adequate natural or mechanical ventilation, may be exempt from the provisions of sections 13-809(6) through 13-809(15) of this article, on approval of the fire marshal, when using undercoating materials which are not more hazardous than kerosene, or undercoating materials using only solvents having a flashpoint in excess of 100°F. (b) Undercoating spray operations not conforming with paragraph (a) of this section shall be subject to all applicable provisions of this article.
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.