For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-818 — Magnesium

Code of Ordinances of the City of New Haven, Connecticut (Supp. No. 31: codified through Ordinance No. 2025-0018, enacted September 11, 2025) · New Haven Code of Ordinances § 13-818

Corpus is an independent public-information project, not the official City of New Haven website. Stable reference: corpuslaw.us/code/e292a5dc-38b0-44bb-b296-1194b83c4463

Sec. 13-818. - Magnesium.

(1) General. This section applies to the storage, handling and processing of magnesium. (2) Permit required. No person shall melt, cast, heat, treat, machine or grind more than ten pounds (10 lbs.) of magnesium on any single working day without a permit. (3) Storage of pigs, ingots and billets. (a) No person shall store magnesium pigs, ingots and billets out of doors in piles exceeding one million pounds (1,000,000 lbs.) each, separated by aisles not less in width than one-half (½) the height of pile, and separated from combustible material or buildings on the same adjoining property by a distance of not less than the height of the nearest pile. (b) No person shall store magnesium pigs, ingots and billets in buildings except on floors of noncombustible construction, in piles not larger than five hundred thousand pounds (500,000 lbs.) each, separated by aisles not less in width than one-half (½) the height of the pile. (4) Melting pots. No person shall melt magnesium unless the floors under and around melting pots are of noncombustible construction. (5) Storage of magnesium articles in foundries and processing plants. No person shall store magnesium in foundries or processing plants in piles exceeding one thousand two hundred fifty cubic feet (1,250 cu. ft.) which are separated by aisles not less in width than one-half (½) the height of pile. (6) Heat treating ovens. No person shall heat magnesium unless approved means shall be provided for control of magnesium fires in heat treating ovens. (7) Magnesium processing operations. No person shall conduct any magnesium processing operation in violation of the following: (a) At each grinding, buffing or wire brushing operation on magnesium, not including rough finishing of castings, dust shall be collected by means of suitable hoods or enclosures connected to a liquid precipitation type of separator, such that the dust will be converted to sludge without contact in a dry state with any high speed moving parts. (b) Connecting ducts or suction tubes shall be completely grounded and as short as possible, with no unnecessary bends. Ducts shall be carefully fabricated and assembled, with a smooth interior and with internal lap joints pointing in the direction of air flow, and without unused capped side outlets, pockets or other dead-end spaces which might allow an accumulation of dust. (c) Each machine shall be equipped with its individual dust separating unit, except that with multi-unit machines not more than two dust-producing units may be served by one separator. Not more than four portable dust-producing units in a single enclosure or stand may be served by one separator unit. (d) Power supply to machines shall be interlocked with (1) exhaust air flow and (2) liquid pressure level or flow in such a way that improper functioning of the dust removal and separator system will shut down the machine it serves. (e) All electric wiring, fixtures and equipment in the immediate vicinity of and attached to dust-producing machines, including those used in connection with separator equipment, shall be of types approved for use in Class II, Group E hazardous locations under the National Electrical Code and shall be installed in accordance with nationally recognized safe practice. Compliance with applicable provisions of the standard of the National Board of Fire Underwriters known as the "National Electrical Code" shall be deemed prima facie evidence of compliance with nationally recognized safe practice. (f) All equipment shall be securely grounded by permanent ground wires. (8) Fire extinguishing powder. Any person heating magnesium shall keep a supply of approved extinguishing powder in a substantial container with a hand scoop or shovel for applying powder on magnesium fires or an approved extinguisher unit designed for use with such powder within easy reach of every operator performing a machining, grinding or other processing operation on magnesium. (9) Storage of magnesium articles in warehouses and stores. No person shall keep or store magnesium articles in violation of the following: (a) Magnesium storage in quantity greater than fifty cubic feet (50 cu. ft.) shall be separated from storage of other materials that are either combustible or in combustible containers, by aisles equal in width to not less than the height of the piles of magnesium. (b) Magnesium storage in quantity greater than one thousand cubic feet (1,000 cu. ft.) shall be separated into piles each not larger than one thousand cubic feet (1,000 cu. ft.) with aisles between equal in width to not less than the height of the piles. (c) Where storage in quantity greater than one thousand cubic feet (1,000 cu. ft.) is in a building of combustible construction, or the magnesium is packed in combustible crates or cartons, or there is other combustible storage within thirty feet (30') of the magnesium, the storage area shall be protected by automatic sprinklers. (10) Handling of magnesium fines (fine magnesium scrap). No person shall handle fine magnesium scrap in violation of the following: (a) Chips, turnings and other fine magnesium scrap shall be collected from the pans or spaces under machines and from other places where they collect at least once each working day, and placed in a covered, vented steel container and removed to a safe location. (b) Magnesium fines shall be kept separate from other combustible materials. (c) Storage in quantity greater than fifty cubic feet (50 cu. ft.) of fine magnesium scrap (six fifty-five-gallon (55 gals.) steel drums) shall be separated from other occupancies by fire-resistive construction without window openings or by an open space of at least fifty feet (50'). (d) Storage in quantity greater than one thousand cubic feet (1,000 cu. ft.) shall be separated from all buildings other than those used for magnesium scrap recovery operations by a distance of not less than one hundred feet (100').

Ask a question about New Haven law

Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.