Sec. 13-824. - Places of assembly, public buildings and institutional buildings.
(1) General permit required. (a) In addition to the provisions contained in this code, places of assembly are also regulated by state law. The reader is directed to regulations 29-40-1 through 29-40-226 of the state fire marshal, which regulations constitute the Connecticut fire safety code, and regulations 29-109-1 through 29-109-116 of the commissioner of state police governing places of assembly, hotels, hospitals, convalescent homes, schools, boarding homes, rooming houses, child day care centers and related facilities. These regulations contain comprehensive requirements regarding entrances, exits, exit signs, maximum occupancy, standing room conditions, physical design and location of structures, aisles, emergency lighting, housekeeping and other physical features. In addition, special requirements are provided for structures used for specific purposes. (b) No place of assembly shall be maintained, operated or used as such without a permit, except that no permit shall be required for any place of assembly used solely as a place of religious worship. (2) Decorative material. No person shall maintain or permit any Place of Assembly, Public Building or Institutional Building to be maintained in violation of the following: (a) No decorative material shall be used which as applied will ignite and allow flame to spread over the surface when exposed to match flame test applied to a piece removed from the material and tested in a safe place. The piece shall be held in a vertical position and the bottom edge exposed to a flame from a common match held in a horizontal position, one-half inch underneath the piece, and at a constant location for a minimum of fifteen (15) seconds. (b) Treatments used to accomplish this flameproofing shall be renewed as often as may be necessary to maintain the flameproof effect. (3) Pyroxylin coated fabric. No person shall maintain or permit any Place of Assembly, Public Building or Institutional Building to be maintained in violation of the following: Pyroxylin coated fabric used as a decorative material in accordance with section 13-824(2), or as a surface covering on fixed furnishings, shall be limited as follows: Such fabrics containing one and four-tenths ounces (1.4 ozs.) or more of cellulose nitrate per square yard shall not be used in excess of a total amount equivalent to one square foot of fabric surface to fifteen cubic feet (15 cu. ft.) of room volume. Each square foot of such fabric which contains one and seven-tenths ounces (1.7 ozs.) or more of cellulose nitrate per square yard shall be counted as two square feet in making this computation. (4) Motion picture screens. No person shall use or permit a motion picture screen or screen masking to be used in any place of assembly, public building, or institutional building which will ignite and allow flame to spread over the surface when exposed to the match flame test described in section 13-824(2). (5) Exit doors. No person shall permit a place of assembly, public building or institutional building to be occupied when any exit door shall be locked, bolted, or otherwise fastened or obstructed by any means, so that the door cannot be opened from the inside by the use of the ordinary door latch or knob or by pressure on the door or on a panic release device. (6) Aisles. No person shall permit a place of assembly, public building or institutional building to be occupied unless in each room where chairs, or tables and chairs, are used, the arrangement shall be such as will provide for ready access by aisles to each exit doorway. Aisles leading directly to exit doorways shall have not less than thirty-six inches (36") clear width which shall not be obstructed by chairs, tables or other objects. (7) Use of exit ways. No person shall permit a place of assembly, public building or institutional building to be occupied of any part of a stairway, whether interior or exterior, or of a hallway, corridor, vestibule, balcony or bridge leading to a stairway or exit of any kind, will be used in any way that will obstruct its use as an exit or that will present a hazardous condition. (8) Ash trays. Any person permitting a place of assembly, public building or institutional building to be occupied shall provide on each table and other convenient places in areas where smoking is permitted, suitable noncombustible ash trays or match receivers. (9) Open flames. Open flame illuminating devices presenting a reasonable threat of fire are prohibited. (10) Plan of exit ways and aisles. No person shall permit a place of assembly, public building or institutional building to be occupied unless a plan showing the capacity and location of exit ways and of aisles leading thereto has been submitted and approved by the fire marshal and an approved copy placed and kept on display in the premises. (11) Marking and lighting of exits. No person shall permit a place of assembly, public building or institutional building to be occupied unless all fire escapes and exitways in places of assembly shall be marked and lighted in accordance with section 13-826 of this Code.
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.