Sec. 13-831. - Welding or cutting, calcium carbide and acetylene generators.
(1) General. Welding or cutting shall include gas, electric-arc, or flammable liquid welding or cutting or any combination thereof. (2) Permit required for welding or cutting. (a) A permit shall be required of each company, corporation, co-partnership or owner-operator performing welding or cutting operations except as provided in paragraph (b) of this subsection (2). This permit shall not be required for each welding or cutting job location. The company, corporation, co-partnership or owner-operator shall notify the fire marshal in advance where such work is taking place except where such work is done in response to an emergency call that does not allow time for the fire marshal to be notified in advance of the work. A fee of shall be paid for each permit as set out in section 17-20 of this Code. (b) A permit shall not be required of any company, corporation, co-partnership, or owner-operator: (1) Where the welding or cutting is performed in areas approved for the purpose, or (2) Having an approved permit system established for control of the fire hazards involved. (c) Application for a permit required by this article shall be made by the company, corporation, co-partnership or owner-operator performing the welding or cutting operation or by his duly authorized agent. (d) A permit for welding or cutting operations shall not be issued unless the individuals in charge of performing such operations are capable of doing such work in a safe manner. Demonstration of a working knowledge of the provisions of this article shall constitute acceptable evidence of compliance with this requirement. (e) Companies, corporations, co-partnerships and owner-operators required to have a permit shall maintain a record of all locations where welding or cutting operations are performed and have it available for inspection by the fire marshal. (3) Compliance with nationally recognized good practice. No person shall use or permit to be used any welding or cutting equipment unacceptable to the fire marshal and the equipment shall be installed and operated in accordance with nationally recognized good practice. (4) Fire prevention. No person shall weld or perform any cutting operation in violation of the following: (a) Before welding or cutting operations are begun in areas not designed or approved for the purpose, specific authorization shall be obtained from the owner of the premises or his duly authorized agent. (b) When welding or cutting operations are performed above, or within thirty-five feet (35') of combustible construction or material exposed to the operation, or within thirty-five feet (35') of floor, ceiling or wall openings so exposed: (1) Such combustible construction or material shall be protected by noncombustible shields or covers from possible sparks, hot metal or oxide. (2) Such floor, ceiling or wall openings shall be protected by noncombustible shields or covers. (3) A fire watcher shall be provided to watch for fires, make use of portable fire extinguishers or fire hose, and perform similar fire prevention and protection duties. The fire watcher shall remain on the job at least thirty (30) minutes after the welding or cutting operations have been completed to insure that no fire exists. A signed inspection report attesting to that fact shall be filed and available for inspection by the Bureau of Fire Prevention. (c) One or more portable fire extinguishers of approved type and size shall be kept at the location where welding or cutting is to be done. (d) Welding or cutting shall not be done in or near rooms or locations where flammable gases, liquids or vapors, lint, dust, or loose combustible stocks are present when sparks or hot metal from the welding or cutting operations may cause ignition or explosion of such materials. (e) Except as provided in paragraph (f) of this subsection, welding or cutting shall not be performed on containers and equipment which contain or have contained flammable liquids, gases or solids until these containers and equipment have been thoroughly cleaned or inerted or purged. (f) "Hot tapping" may be permitted on tanks and pipe lines provided such operations are performed by companies, corporations, copartnerships or owner-operators not required to have a permit under section 13-831(2)(b)(2). (g) Sprinkler protection shall not be shut off while welding or cutting work is being performed. When welding or cutting is done close to automatic sprinkler heads, sheet asbestos or damp cloth guards may be used to shield the individual heads but shall be removed when the work is completed. (5) Gas welding and cutting. No person shall use gas in welding or cutting in violation of the following: (a) Devices or attachments facilitating or permitting mixture of air or oxygen with combustible gases prior to consumption, except at the burner or in a standard torch or blowpipe, shall not be allowed unless approved for the purpose. (b) The user shall not transfer gases from one cylinder to another or mix gases in a cylinder. (c) Acetylene gas shall not be generated, piped (except in approved cylinder manifolds and cylinder manifold connections), or utilized at a pressure in excess of fifteen pounds (15 lbs.) per square inch gauge unless dissolved in a suitable solvent in cylinders manufactured according to Interstate Commerce Commission requirements. (d) Acetylene gas shall not be brought in contact with unalloyed copper except in a blowpipe or torch. (e) A cylinder or cylinder manifold for oxygen shall be provided with a pressure regulating device intended for use with oxygen, and so marked. (f) Cylinders permitted inside of buildings shall be stored at least twenty feet (20') from highly combustible materials and in locations where they are not subject to excessive rise in temperature, physical damage or tampering by unauthorized persons. Empty cylinders shall have their valves closed in storage and when shipped. (g) When a cylinder is not in use, the valve shall be closed and the valve protection cap shall be in place, hand tight. (h) Tests for leaks in any piping system or equipment shall be made with soapy water. Flames shall not be used. (i) Welding or cutting work shall not be supported on compressed gas cylinders or other containers. (j) Fuel gas cylinders shall be placed with valve end up whenever they are in use. (k) Fuel gas shall not be used from cylinders through torches or other devices equipped with shut-off valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold. (l) Cylinders, valves, regulators, hose and other apparatus and fittings containing or using oxygen shall be kept free from oil or grease. Oxygen cylinders, apparatus and fittings shall not be handled with oily hands or gloves or greasy tools or equipment. (m) When moving compressed gas cylinders by crane, suitable cradles shall be used to prevent the possibility of dropping them. Ordinary rope slings or electromagnets shall not be used. (n) Oxygen and fuel gas cylinders and acetylene generators shall be placed far enough away from the welding area to prevent them from being heated by radiation from heated materials, by sparks or slag, or by misdirection of the torch flame. (o) When gas welding or cutting operations are discontinued for a substantial period of time such as during lunch hour or overnight, the torch valves shall be closed and the gas supply to the torch completely shut off. (6) Electric arc-welding and cutting. No person shall electric arc-weld or cut in violation of the following: (a) The frame or case of the welding machine except internal combustion engine driven machines shall be grounded. Ground connections shall be mechanically strong and electrically adequate for the required current. (b) Welding current return circuits from the work to the machine shall have proper electrical contact at all joints and periodic inspection shall be made to ascertain that proper electrical contact is maintained. (c) When electric arc welding or cutting is to be discontinued for any substantial period of time, such as during lunch hour or overnight, all electrodes shall be removed from the holders, the holders shall be carefully located so that accidental contact cannot occur, and the machines shall be disconnected from the power source. (7) Permit required for storage of calcium carbide. No person without a permit shall store or keep calcium carbide in excess of two hundred pounds (200 lbs.). (8) Containers for calcium carbide. No person shall store or permit calcium carbide to be stored in any container which is not of sufficient strength to insure handling without rupture, and which is not provided with a screw top or its equivalent. The containers shall be of water-tight and air-tight construction. Solder shall not be used on joints in such manner that fire would disrupt the package. Packages shall be marked "Calcium Carbide—Dangerous If Not Kept Dry". (9) Storage of calcium carbide in buildings. No person shall store or permit calcium carbide to be stored in violation of the following: (a) Storage of calcium carbide inside buildings shall be in a dry, waterproof and well ventilated location. (b) Calcium carbide not in excess of six hundred pounds (600 lbs.) may be stored inside of buildings or in the same room with fuel gas cylinders but not with oxygen cylinders. (c) Calcium carbide in excess of six hundred pounds (600 lbs.) but not in excess of five thousand pounds (5,000 lbs.) shall not be stored in a building containing other occupancy unless in an acetylene generator room or separate room or compartment, in a one-story building without cellar or basement underneath the carbide storage section. Such rooms shall be of construction having a fire resistance rating of not less than one (1) hour, with openings to other parts of the building protected by approved self-closing fire doors or stationary wired glass windows in approved metal frames. Adequate ventilation shall be provided. This room shall not be used for any other purpose. (d) Calcium carbide in excess of five thousand pounds (5,000 lbs.) shall be stored in one story buildings without cellar or basement and used for no other purpose, or in outside acetylene generator houses. Location of such storage buildings shall be outside congested mercantile and manufacturing districts. If storage building is of noncombustible construction, it may adjoin other one story buildings if separated therefrom by unpierced fire walls; if detached less than ten feet (10') from such building or buildings, there shall be no opening in any of the mutually exposing sides of such buildings within said distance. If the storage building is of combustible construction it shall not be within twenty feet (20') of any other one or two story building, nor within thirty feet (30') of any other building exceeding two stories. (10) Permit required for acetylene generators. No person shall operate an acetylene generator having a carbide capacity exceeding five pounds (5 lbs.) without a permit. (11) Generators to be approved. No person shall operate or permit any acetylene generators to be operated which are not of an approved type, and are not plainly marked with the rate in cubic feet of acetylene per hour for which they are designed, the amount or weight of carbide necessary for a single charge, the manufacturer's name and address, and the name or number of the type of generator. (12) Stationary generators. No person shall install stationary generators which are not either in a well ventilated one story noncombustible outside generator house, or in a well ventilated room or compartment of ample size and of construction as outlined in section 13-831(13), either in a one story building or on the top floor or roof of a multi-storied building. The storage of fuel gas cylinders in such rooms or compartments shall not exceed a total capacity of two thousand cubic feet (2,000 cu. ft.) of gas (300 pounds in case of liquefied petroleum gas). (13) Inside generator rooms or compartments. No person shall install, operate or permit acetylene generators in violation of the following: (a) The walls or partitions, floor and ceiling of such room or compartment shall be of construction having a fire resistance rating of not less than one hour. Walls or partitions shall be continuous from floor to ceiling and shall be securely anchored. At least one wall of an inside generator room shall be an exterior wall. (b) Openings from generator room or compartment to other parts of the building shall be protected by an approved self-closing fire door of the swinging type and close into a rabbet, or otherwise be made tight to prevent passage of flame around edges. Exit doors shall be located so as to be readily accessible in case of emergency. Windows, if provided in partitions, shall be wired glass in approved metal frames with fixed sash. (c) A portion of the exterior walls equal to not less than ten percent (10%) of the combined areas of the enclosing walls shall be of light noncombustible material such as single thickness, single strength glass. Single thickness, single strength window glass skylights, or lightly fastened roof hatch covers, swinging doors in exterior wall opening outward, sheet metal siding or lightly fastened roofs, may be accepted in part or entirely in lieu of the glass area or its equivalent, provided the required percentage of explosion venting area is thus obtained. (14) Portable generators. (a) No person shall use or cause a portable generator to be used in rooms of total volume less than thirty-five (35) times the total gas generating capacity per charge of all generators in the room. The gas generating capacity in cubic feet per charge shall be assumed as four and five tenths (4.5) times the weight of carbide per charge in pounds. Generators shall not be used in rooms having a ceiling height less than ten feet (10'). (b) No person shall move or cause an acetylene generator to be moved by derrick, crane or hoist while charged. (15) Protection against freezing. No person shall place or cause a generator to be placed where water will freeze. No common salt (sodium chloride) or other corrosive chemical shall be used as a protection against freezing. (16) Permit required for cylinder storage. A permit shall be required for the storage of cylinders used in conjunction with welding or cutting operations when more than two thousand cubic feet (2,000 cu. ft.) of flammable compressed gas other than liquefied petroleum gas, three hundred pounds (300 lbs.) of liquefied petroleum gas, or six thousand cubic feet (6,000 cu. ft.) of nonflammable compressed gas is stored. (17) Storage of cylinders. No person shall store or cause welding cylinders of fuel gas to be stored in violation of the following: (a) Cylinders of fuel gases stored inside of building. except those in actual use or attached ready for use, shall be limited to a total capacity of two thousand cubic feet (2,000 cu. ft.) of gas or three hundred pounds (300 lbs.) of liquefied petroleum gas. For storage in excess of two thousand cubic feet (2,000 cu. ft.) total gas capacity of cylinders or three hundred pounds (300 lbs.) of liquefied petroleum gas, a separate room or compartment as provided for by section 13-831(9)(c) shall be provided, or cylinders shall be kept outside or in a special building. Buildings, rooms or compartments provided for such storage shall be well ventilated and be without open flame heating or lighting devices. (b) Cylinders or oxygen stored inside of buildings shall comply with the requirement for oxygen manifolds covered in section 13-831(19)(a). (18) Piping systems for fuel gases and oxygen. No person shall install or use or cause any piping system for fuel gases and oxygen to be installed in violation of the following: (a) Except as provided in paragraphs (b) and (c) of this section, piping shall be steel, wrought iron, brass or copper pipe, or seamless copper, brass, or stainless steel tubing. Piping and fittings shall comply with nationally recognized good practice except that pipe and fittings shall be standard weight as a minimum for sizes not over six inches in nominal size. (b) Acetylene piping shall be steel or wrought iron pipe only. (c) Oxygen piping at pressures in excess of seven hundred pounds (700 lbs.) per square inch shall be stainless steel or nonferrous tubing. (d) Joints in steel or wrought iron pipe shall be welded or made up with threaded or flanged fittings; or rolled, forged or cast steel, or malleable iron fittings may be used. Joints in brass or copper pipe may be welded, brazed, threaded or flanged. Joints in seamless copper, brass or stainless steel tubing shall be by approved gas tubing fittings or shall be brazed. Socket type joints in brass or copper pipe or in seamless copper, brass or stainless steel tubing shall be brazed with silver brazing alloy or similar high melting point filler metal. Cast iron fittings shall be prohibited. Threaded connections in oxygen piping shall be tinned, or made up with litharge and glycerine, or other joint compound approved for oxygen service and applied to male threads only. (e) Piping shall be protected against physical damage, and allowance made for contraction, expansion, jarring and vibration. If laid underground it shall be below the frost line and protected against corrosion. Low points in piping shall be provided with drip pots and drain valves, the latter to be normally closed with screw caps or plugs. (f) All piping shall be tested and proved tight at one and one-half times its maximum working pressure. Any medium used for testing oxygen lines shall be oil-free. (g) All buried pipe and tubing and outdoor ferrous pipe and tubing shall be covered or painted with a suitable corrosion resisting material. (19) Manifolding of cylinders. No person shall install, use or cause welding cylinders to be used in violation of the following: (a) Oxygen manifolds shall not be located in an acetylene generator room. Oxygen manifolds shall be located at least twenty feet (20') away from both highly flammable material, such as oil or grease and combustible gas cylinders unless the combustible gas cylinders are separated by a fire-resistive partition constructed as specified in section 13-831(9)(c). (b) The aggregate capacity of oxygen cylinders connected to one manifold inside a building shall not exceed six thousand cubic feet (6,000 cu. ft.). More than one such manifold may be located in the same room provided the manifolds are at least fifty feet (50') apart. (c) An oxygen manifold connected to cylinders having an aggregate capacity of more than six thousand cubic feet (6,000 cu. ft.) shall be located outside, in a separate building, or in a separate room constructed in accordance with section 13-831(9)(c) with no combustible material within twenty feet (20') of the manifold. (d) Oxygen manifolds with service pressures not exceeding two hundred pounds (200 lbs.) per square inch gage shall be marked: Low Pressure Manifold Do Not Connect High-Pressure Cylinders Maximum Pressure—250 PSIG (e) The aggregate capacity of fuel gas cylinders connected to one manifold inside a building shall not exceed three thousand cubic feet (3,000 cu. ft.) of gas or three hundred pounds (300 lbs.) of liquefied petroleum gas. More than one such manifold may be located in the same room provided the manifolds are at least fifty feet (50') apart. (f) A fuel gas manifold connected to cylinders having an aggregate capacity of more than three thousand cubic feet (3,000 cu. ft.) of gas or three hundred pounds (300 lbs.) of liquefied petroleum gas shall be located outside, in a separate building, or in a separate room constructed in accordance with section 13-831(9)(c). (20) Hose and hose connections. No person shall use or cause welding hose or welding hose connection to be used in violation of the following: (a) Hose shall be capable of withstanding a hydrostatic pressure of at least eight hundred pounds (800 lbs.) per square inch. (b) A single hose having more than one gas passage, a wall failure of which would permit the flow of one gas into the other gas passage shall not be used. (c) Single and double hose except as provided in paragraph (d) of this section shall be identified by exterior colors using green for oxygen hose, red for acetylene, LP-Gas and other fuel gases and black for inert gases and air hose. (d) When two hoses are joined by a web to form integral lengths of double hose, the color of both hoses shall be red and the exterior surface of oxygen hose shall be smooth to the touch while fuel gas hose shall be corrugated or ribbed. (e) When parallel lengths of oxygen and acetylene hose are taped together for convenience and to prevent tangling, not more than four inches out of each eight shall be covered by tape. (f) Hose connections shall be clamped or otherwise securely fastened in a manner that will withstand, without leakage, twice the pressure to which they are normally subjected in service but in no case less than a pressure of three hundred pounds (300 lbs.) per square inch. (g) Hose shall be inspected frequently for leaks, burns, worn places, loose connections or other defects, which may render the hose unfit for service. Where hose shows excessive wear or has been subjected to flashback it shall be inspected and tested at twice the normal pressure to which it is subjected in service but in no case at less than two hundred pounds (200 lbs.) per square inch before being returned to service. Defective lengths of hose shall be discarded.
(Ord. of 12-4-89; Ord. of 5-24-99; Ord. No. 1345, 2-2-04; Ord. No. 1386, 7-5-05)
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.